Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 18 min ago
Peer-reviewedCC BYClinics and practice

Artificial Intelligence-Enabled Maternal and Fetal Monitoring Devices in Pregnancy: A Global Scoping Review and Evidence Mapping.

8 affiliations
  1. 1Institute for Global Health and Wellbeing, School of Medicine, Keele University, Newcastle-under-Lyme ST5 5BG, UK.
  2. 2Department of Public Health, School of Allied Health Sciences, Miva Open University, Plot 1059, O.P. Fingesi Road, Utako, Abuja 900101, Federal Capital Territory, Nigeria.
  3. 3Department of Public Health, Faculty of Medicine, Universitas Padjadjaran, Bandung 40161, Indonesia.
  4. 4Department of Obstetrics and Gynaecology, College of Medicine, Ekiti State University, Ado-Ekiti P.M.B. 5363, Ekiti State, Nigeria.
  5. 5Department of Obstetrics and Gynaecology, Nnamdi Azikiwe University Teaching Hospital, Nnewi P.M.B. 5025, Anambra State, Nigeria.
  6. 6Department of Obstetrics, Gynaecology and Perinatology, Faculty of Clinical Sciences, Obafemi Awolowo University, Ile-Ife P.M.B. 13, Osun State, Nigeria.
  7. 7Department of Internal Medicine, Ivano-Frankivsk National Medical University, 76018 Ivano-Frankivsk, Ukraine.
  8. 8Department of Public Health, Daffodil International University, Daffodil Smart City, Birulia, Savar, Dhaka 1216, Bangladesh.

Abstract

Background

Artificial intelligence (AI) is increasingly used in obstetric ultrasound, cardiotocography, wearable fetal electrocardiography, and remote maternal-fetal monitoring. Evidence on real-world implementation, including feasibility, acceptability, workflow, task sharing, sustainability, equity, cost, and user experience, remains limited. This review aimed to map global real-world implementation evidence for AI-enabled obstetric monitoring and identify outcomes, determinants, gaps, and research priorities for scale-up.Methods

We conducted a scoping review using the Arksey and O'Malley framework with Levac refinements, Joanna Briggs Institute guidance, and PRISMA-ScR. PubMed/MEDLINE, Web of Science, and Dimensions were searched from January 2010 to May 2026 and Scopus from January 2010 to December 2025. We included studies on AI-enabled obstetric monitoring in clinical or community settings and primary research on implementation readiness. We classified findings as operational (Tier 1) or readiness (Tier 2), mapped outcomes to RE-AIM, and interpreted determinants using NASSS.Results

Thirteen studies met the criteria: ten on AI-enabled obstetric ultrasound, two on AI-assisted cardiotocography, and one on wearable fetal electrocardiography. Seven were Tier 1 and six Tier 2; ten were conducted in LMICs or mainly represented LMIC stakeholders. Included studies reported higher ultrasound process-quality measures, shorter expert-review time, feasible image acquisition, high acceptability, and potential for task sharing. Selection bias, confounding, short follow-up, and reliance on proximal outcomes limited inference. No randomized trial showed improved maternal or neonatal outcomes, and no complete cost-effectiveness evaluation met the criteria.Conclusions

Implementation evidence remains sparse, recent, and concentrated in AI-enabled ultrasound. Pragmatic comparative studies, long-term implementation research, economic evaluation, safety monitoring, referral completion, and equitable scale-up should be prioritized.

Related

  1. Artificial Intelligence–Driven Multimodal Imaging for Cancer During Pregnancy: Advances in Maternal–Fetal Diagnostics and Precision Oncology
    Ohmini Krishnamurthy Rajendran
    International Journal of Drug Delivery TechnologyPeer-reviewedLicence not statedFull text20 citedEpidemiology & public healthOpenAlex
  2. Circulating Biomarkers with Artificial Intelligence for Clinical Risk Assessment and Therapeutic Monitoring: Evidence, Limitations, and Translation
    Wenyuan Wei, Rui Zhang, Zhiying Zhang
    Therapeutics and Clinical Risk ManagementPeer-reviewedCC BY-NC 4.0Full textOncologyPMC
  3. Maternal Health Trends and Disparities in Hawaiʻi: Visualizing Pregnancy Risk Assessment Monitoring System Data Through an Interactive Shiny Web Application
    Noa Brenner, Kyle Ishikawa, Ashley Graham +4
    Hawai'i Journal of Health & Social WelfarePeer-reviewedLicence not statedFull textObstetrics, gynaecology & paediatricsPMC
  4. Early-to-mid-pregnancy maternal free thyroxine and fetal growth velocity trajectories: evidence from a large prospective cohort
    Honglin Jiang, Zhe Mu, Yongzhou Liang +3
    BMC MedicinePeer-reviewedCC BY-NC-ND 4.0Endocrinology & metabolismCrossref
  5. Athlete-AI: a multi-modal artificial intelligence framework for personalized athlete monitoring and injury risk forecasting
    R. Kanthavel, R. Dhaya, Satish R. Jondhale +2
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textSurgery & anaesthesiaCrossref
BibTeX
@article{adepoju2026artificial,
  title = {{Artificial Intelligence-Enabled Maternal and Fetal Monitoring Devices in Pregnancy: A Global Scoping Review and Evidence Mapping.}},
  author = {Victor Abiola Adepoju and Qorinah Estiningtyas Sakilah Adnani and Ajayi Babatunde Olofinbiyi and George Uchenna Eleje and Ibraheem Olayemi Awowole and Shankar Biswas and Abm Alauddin Chowdhury},
  journal = {Clinics and practice},
  year = {2026},
  month = oct,
  doi = {10.3390/clinpract16110198},
  url = {https://europepmc.org/article/MED/43082313},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Artificial Intelligence-Enabled Maternal and Fetal Monitoring Devices in Pregnancy: A Global Scoping Review and Evidence Mapping.
AU  - Victor Abiola Adepoju
AU  - Qorinah Estiningtyas Sakilah Adnani
AU  - Ajayi Babatunde Olofinbiyi
AU  - George Uchenna Eleje
AU  - Ibraheem Olayemi Awowole
AU  - Shankar Biswas
AU  - Abm Alauddin Chowdhury
PY  - 2026
DA  - 2026/10/25
JO  - Clinics and practice
DO  - 10.3390/clinpract16110198
UR  - https://europepmc.org/article/MED/43082313
AB  - Background  Artificial intelligence (AI) is increasingly used in obstetric ultrasound, cardiotocography, wearable fetal electrocardiography, and remote maternal-fetal monitoring. Evidence on real-world implementation, including feasibility, acceptability, workflow, task sharing, sustainability, equity, cost, and user experience, remains limited. This review aimed to map global real-world implementation evidence for AI-enabled obstetric monitoring and identify outcomes, determinants, gaps, and research priorities for scale-up.Methods  We conducted a scoping review using the Arksey and O'Malley framework with Levac refinements, Joanna Briggs Institute guidance, and PRISMA-ScR. PubMed/MEDLINE, Web of Science, and Dimensions were searched from January 2010 to May 2026 and Scopus from January 2010 to December 2025. We included studies on AI-enabled obstetric monitoring in clinical or community settings and primary research on implementation readiness. We classified findings as operational (Tier 1) or readiness (Tier 2), mapped outcomes to RE-AIM, and interpreted determinants using NASSS.Results  Thirteen studies met the criteria: ten on AI-enabled obstetric ultrasound, two on AI-assisted cardiotocography, and one on wearable fetal electrocardiography. Seven were Tier 1 and six Tier 2; ten were conducted in LMICs or mainly represented LMIC stakeholders. Included studies reported higher ultrasound process-quality measures, shorter expert-review time, feasible image acquisition, high acceptability, and potential for task sharing. Selection bias, confounding, short follow-up, and reliance on proximal outcomes limited inference. No randomized trial showed improved maternal or neonatal outcomes, and no complete cost-effectiveness evaluation met the criteria.Conclusions  Implementation evidence remains sparse, recent, and concentrated in AI-enabled ultrasound. Pragmatic comparative studies, long-term implementation research, economic evaluation, safety monitoring, referral completion, and equitable scale-up should be prioritized.
SN  - 2039-7275
SN  - 2039-7283
ER  -