SET-ANUBIS: a modular pipeline for ANUBIS long-lived particle sensitivity studies
Abstract
The proposed ANUBIS detector has been designed to search for Long-Lived Particle (LLP) signatures, which have become a focus for a variety of experiments within recent years. Due to the variety of possible LLP models and the need for directly comparable sensitivity results highlighting the potential coverage of ANUBIS, the SET-ANUBIS (Simulation, accEptance and sensiTivity studies framework for ANUBIS) framework has been developed. SET-ANUBIS is a flexible open-source Python framework that can perform full sensitivity studies of LLP signatures for the ANUBIS detector, allowing others to directly produce ANUBIS-like limits or even implement other geometries and detectors. It starts from a Universal FeynRules Output model or user-supplied rates; it exposes model parameters and particle content for user modification, and evaluates decay widths, branching ratios and lifetimes. MARTY can also be used to compute matrix elements, decay widths, branching ratios, and cross-sections. Then the framework prepares or runs event generation through Pythia8 or MadGraph, ingests HepMC event records, models the geometry of the ATLAS cavern and ANUBIS tracking stations, and applies a configurable sequence of geometric, kinematic and isolation requirements to select a set of surviving LLP candidates for evaluation. The implementation follows a ports-and-adapters architecture so that the core logic remains separate from external generators, persistent storage and visualisation. A scan-aware SQLite catalogue and content-addressed store preserve cards, metadata and compact selection-ready event bundles while avoiding duplicate artifacts. A pre-release version of the SET-ANUBIS framework has already been used to successfully derive the sensitivity of ANUBIS to three LLP benchmark models involving a Higgs portal and a Heavy Neutral Lepton model.
Related
- Projected sensitivity of the \anubis detector to photophobic and fermion-coupled axion-like particles
- CtaAgnVar : a Pipeline for Variability Studies with the Cherenkov Telescope Array Observatory
- The conductance filtration: sink-relative persistence and exact edge sensitivity for heat transport in particle-filled composites
- Implementation and verification of the avalanche source in a 3D full-f particle-in-cell model of relativistic electrons for studies of tokamak disruptions
- sRQA: an integrative pipeline for symbolic recurrence quantification analysis
BibTeX
@misc{erner2026setanubis,
title = {{SET-ANUBIS: a modular pipeline for ANUBIS long-lived particle sensitivity studies}},
author = {Sofie Nordahl Erner and Anna Mullin and Théo Reymermier and Paul Swallow and Oleg Brandt for the ANUBIS Collaboration},
howpublished = {arXiv},
year = {2026},
month = sep,
doi = {10.48550/arxiv.2607.26112},
eprint = {2607.26112},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2607.26112},
note = {CC BY-NC-ND 4.0},
}
RIS
TY - UNPB
TI - SET-ANUBIS: a modular pipeline for ANUBIS long-lived particle sensitivity studies
AU - Sofie Nordahl Erner
AU - Anna Mullin
AU - Théo Reymermier
AU - Paul Swallow
AU - Oleg Brandt for the ANUBIS Collaboration
PY - 2026
DA - 2026/09/10
PB - arXiv
DO - 10.48550/arxiv.2607.26112
UR - https://arxiv.org/abs/2607.26112
AB - The proposed ANUBIS detector has been designed to search for Long-Lived Particle (LLP) signatures, which have become a focus for a variety of experiments within recent years. Due to the variety of possible LLP models and the need for directly comparable sensitivity results highlighting the potential coverage of ANUBIS, the SET-ANUBIS (Simulation, accEptance and sensiTivity studies framework for ANUBIS) framework has been developed. SET-ANUBIS is a flexible open-source Python framework that can perform full sensitivity studies of LLP signatures for the ANUBIS detector, allowing others to directly produce ANUBIS-like limits or even implement other geometries and detectors. It starts from a Universal FeynRules Output model or user-supplied rates; it exposes model parameters and particle content for user modification, and evaluates decay widths, branching ratios and lifetimes. MARTY can also be used to compute matrix elements, decay widths, branching ratios, and cross-sections. Then the framework prepares or runs event generation through Pythia8 or MadGraph, ingests HepMC event records, models the geometry of the ATLAS cavern and ANUBIS tracking stations, and applies a configurable sequence of geometric, kinematic and isolation requirements to select a set of surviving LLP candidates for evaluation. The implementation follows a ports-and-adapters architecture so that the core logic remains separate from external generators, persistent storage and visualisation. A scan-aware SQLite catalogue and content-addressed store preserve cards, metadata and compact selection-ready event bundles while avoiding duplicate artifacts. A pre-release version of the SET-ANUBIS framework has already been used to successfully derive the sensitivity of ANUBIS to three LLP benchmark models involving a Higgs portal and a Heavy Neutral Lepton model.
ER -