Discordance Between CO₂- and pH-Based Apnea Test Criteria for Brain Death: The Importance of the Pre-Test Acid–Base State
- 1Department of Anesthesiology and Reanimation, Division of Critical Care, University of Health Sciences, Antalya Training and Research Hospital, 07100 Antalya, Türkiye
Abstract
Background and Objectives: Apnea test criteria differ between countries and have changed within them. The 2010 American Academy of Neurology guideline accepted a PaCO₂ ≥ 60 mmHg or a rise of ≥20 mmHg above baseline; the 2023 AAN/AAP/CNS/SCCM consensus guideline requires both, together with an arterial pH < 7.30; and the Turkish Ministry of Health guide issued in December 2025 requires both carbon dioxide conditions but no pH target. We examined how the same real-world apnea tests are classified under these three criteria, and what accounts for any disagreement between them. Materials and Methods: All three criteria were applied retrospectively to every apnea test performed during brain death determination in a Turkish tertiary intensive care service between 2019 and 2026 (n = 331 determinations). The primary endpoint was retrospective fulfilment of the 2023 consensus criterion. Determinants were modeled with Firth penalized logistic regression, with the Turkish criterion as the negative control. Results: Of 237 evaluable adults, 98.3% met the 2010 AAN guideline, 87.8% the Türkiye 2025 guide and 78.1% the 2023 criterion; no test gained positivity at any step. Of the 48 tests (20.3%) positive under some but not all criteria, 25 were reclassified by requiring both carbon dioxide conditions and 23 by adding the pH condition. All 23 tests that met the Turkish criterion but failed the 2023 criterion had begun with a pre-test pH above 7.45; among the 118 tests begun at a pH of 7.35–7.45, the two criteria classified every test identically. Pre-test bicarbonate was associated with meeting the 2023 criterion (OR 0.84 per mmol/L, 95% CI 0.78–0.92) but not with the Turkish criterion (OR 1.09, 95% CI 0.98–1.20). Conclusions: Applied retrospectively, the two contemporary criteria disagreed only in tests begun with pre-test alkalemia. Correcting the pre-test acid–base state appears more consequential than the choice between these criteria; the prospective yield of each guideline remains to be established.
Related
- Discordance Between CO2- and pH-Based Apnea Test Criteria for Brain Death: The Importance of the Pre-Test Acid–Base State
- Clinical utility and limitations of transcranial Doppler in evaluating pediatric brain death or death by neurologic criteria: a 10-year retrospective study
- Serial serum biomarkers at 72 h are associated with subsequent brain death/death by neurologic criteria after acute brain injury
- Prediction of death by neurologic criteria in patients with non-traumatic acute brain injury: a systematic review and meta-analysis
- OS05.4.A Discordance between clinician- and patient-reported outcomes during radiotherapy for brain metastases: The prospective NeuroPRO study
BibTeX
@article{asri2026discordance,
title = {{Discordance Between CO₂- and pH-Based Apnea Test Criteria for Brain Death: The Importance of the Pre-Test Acid–Base State}},
author = {Şule Asri and Dilara Tüfek Öztan and Mustafa Ay},
journal = {Medicina},
year = {2026},
month = nov,
doi = {10.3390/medicina62112242},
url = {https://doi.org/10.3390/medicina62112242},
note = {CC BY},
}
RIS
TY - JOUR
TI - Discordance Between CO₂- and pH-Based Apnea Test Criteria for Brain Death: The Importance of the Pre-Test Acid–Base State
AU - Şule Asri
AU - Dilara Tüfek Öztan
AU - Mustafa Ay
PY - 2026
DA - 2026/11/25
JO - Medicina
DO - 10.3390/medicina62112242
UR - https://doi.org/10.3390/medicina62112242
AB - Background and Objectives: Apnea test criteria differ between countries and have changed within them. The 2010 American Academy of Neurology guideline accepted a PaCO₂ ≥ 60 mmHg or a rise of ≥20 mmHg above baseline; the 2023 AAN/AAP/CNS/SCCM consensus guideline requires both, together with an arterial pH < 7.30; and the Turkish Ministry of Health guide issued in December 2025 requires both carbon dioxide conditions but no pH target. We examined how the same real-world apnea tests are classified under these three criteria, and what accounts for any disagreement between them. Materials and Methods: All three criteria were applied retrospectively to every apnea test performed during brain death determination in a Turkish tertiary intensive care service between 2019 and 2026 (n = 331 determinations). The primary endpoint was retrospective fulfilment of the 2023 consensus criterion. Determinants were modeled with Firth penalized logistic regression, with the Turkish criterion as the negative control. Results: Of 237 evaluable adults, 98.3% met the 2010 AAN guideline, 87.8% the Türkiye 2025 guide and 78.1% the 2023 criterion; no test gained positivity at any step. Of the 48 tests (20.3%) positive under some but not all criteria, 25 were reclassified by requiring both carbon dioxide conditions and 23 by adding the pH condition. All 23 tests that met the Turkish criterion but failed the 2023 criterion had begun with a pre-test pH above 7.45; among the 118 tests begun at a pH of 7.35–7.45, the two criteria classified every test identically. Pre-test bicarbonate was associated with meeting the 2023 criterion (OR 0.84 per mmol/L, 95% CI 0.78–0.92) but not with the Turkish criterion (OR 1.09, 95% CI 0.98–1.20). Conclusions: Applied retrospectively, the two contemporary criteria disagreed only in tests begun with pre-test alkalemia. Correcting the pre-test acid–base state appears more consequential than the choice between these criteria; the prospective yield of each guideline remains to be established.
SN - 1648-9144
SN - 1010-660X
ER -