Skip to content
DraconiticResearch
Search Sources API
220,411 studies31 sourcesUpdated 51 min ago
PreprintarXiv licencearXiv

A Goal-Oriented Bayesian Experimental Design to Reduce Uncertainty in Sparse-Angle X-ray Computed Tomography

Abstract

Sparse-angle X-ray computed tomography (CT) presents a challenge for reliable inference, as limited measurements may leave object boundaries unresolved. Bayesian optimal experimental design (BOED) methods select informative measurements, but can be computationally expensive or require data-driven surrogates and do not explicitly exploit microlocal visibility. We address this limitation by focusing on estimating inclusion boundaries rather than the entire attenuation field. For piecewise-constant objects, these boundaries correspond to singularities characterized by their wavefront sets. Microlocal analysis determines the X-ray view-angles at which these singularities are visible. We combine this information with Bayesian uncertainty quantification to introduce B-MUSE, a microlocal uncertainty-driven sequential experimental design method. We define a microlocal C-optimality criterion associated with the wavefront direction of the most uncertain boundary singularity and prove that its optimal solution satisfies the microlocal visibility condition. B-MUSE uses this result to sequentially select informative view-angles according to boundary uncertainty. It also incorporates an adaptive stopping criterion that terminates acquisition when additional measurements provide no meaningful uncertainty reduction. We evaluate B-MUSE through numerical experiments, including interpretable examples, prior-generated inclusions, and a multi-inclusion example from an external dataset, and benchmark it against recent methods. The results show that B-MUSE substantially reduces posterior uncertainty with few adaptively selected measurements while providing boundary estimates. These findings establish a direct connection between BOED and microlocal visibility and demonstrate the potential of uncertainty-driven acquisition to reduce measurement requirements for goal-oriented X-ray CT without training data.

Related

  1. Torus computed tomography for experimental data
    Ella Salo, Alexander Meaney, Olli Koskela +1
    arXivPreprintCC BY 4.0Full textAnalysis & PDEsNumerical analysis & scientific computingarXiv
  2. Risk-Aware Goal-Oriented Bayesian Optimal Experimental Design
    John D. Jakeman, Rebekah White, Bart van Bloemen Waanders +2
    arXivPreprintCC BY 4.0Full textStatisticsarXiv
  3. Enhanced attenuation modelling for multispectral computed tomography
    Jürgen Jeschke, Dirk Lorenz
    arXivPreprintCC BY 4.0Full textNumerical analysis & scientific computingarXiv
  4. Signal recovery in the polychromatic computed tomography model: Injectivity and complexity
    Xuanzhou Chen, Ashwin Pananjady
    arXivPreprintCC BY 4.0Full textGeneral mathematicsBiological & medical physicsarXiv
  5. A Bayesian oriented exploration and reinforcement learning in continuous-time mean-variance portfolio optimization
    Kexin Chen, Xiang Yu, Shanshan Zhao
    arXivPreprintCC BY 4.0Full textOptimisation & controlarXiv
BibTeX
@misc{sabour2026goaloriented,
  title = {{A Goal-Oriented Bayesian Experimental Design to Reduce Uncertainty in Sparse-Angle X-ray Computed Tomography}},
  author = {Mansoure Giahi Sabour and Hassan Yazdanian and Babak Maboudi Afkham},
  howpublished = {arXiv},
  year = {2026},
  month = nov,
  doi = {10.48550/arxiv.2611.14528},
  eprint = {2611.14528},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.14528},
}
RIS
TY  - UNPB
TI  - A Goal-Oriented Bayesian Experimental Design to Reduce Uncertainty in Sparse-Angle X-ray Computed Tomography
AU  - Mansoure Giahi Sabour
AU  - Hassan Yazdanian
AU  - Babak Maboudi Afkham
PY  - 2026
DA  - 2026/11/01
PB  - arXiv
DO  - 10.48550/arxiv.2611.14528
UR  - https://arxiv.org/abs/2611.14528
AB  - Sparse-angle X-ray computed tomography (CT) presents a challenge for reliable inference, as limited measurements may leave object boundaries unresolved. Bayesian optimal experimental design (BOED) methods select informative measurements, but can be computationally expensive or require data-driven surrogates and do not explicitly exploit microlocal visibility. We address this limitation by focusing on estimating inclusion boundaries rather than the entire attenuation field. For piecewise-constant objects, these boundaries correspond to singularities characterized by their wavefront sets. Microlocal analysis determines the X-ray view-angles at which these singularities are visible. We combine this information with Bayesian uncertainty quantification to introduce B-MUSE, a microlocal uncertainty-driven sequential experimental design method. We define a microlocal C-optimality criterion associated with the wavefront direction of the most uncertain boundary singularity and prove that its optimal solution satisfies the microlocal visibility condition. B-MUSE uses this result to sequentially select informative view-angles according to boundary uncertainty. It also incorporates an adaptive stopping criterion that terminates acquisition when additional measurements provide no meaningful uncertainty reduction. We evaluate B-MUSE through numerical experiments, including interpretable examples, prior-generated inclusions, and a multi-inclusion example from an external dataset, and benchmark it against recent methods. The results show that B-MUSE substantially reduces posterior uncertainty with few adaptively selected measurements while providing boundary estimates. These findings establish a direct connection between BOED and microlocal visibility and demonstrate the potential of uncertainty-driven acquisition to reduce measurement requirements for goal-oriented X-ray CT without training data.
ER  -