Skip to content
DraconiticResearch
Search Sources API
197,768 studies31 sourcesUpdated 33 min ago
PreprintCC BY 4.0arXiv

High-Performance Photonic Crystal Biosensors using Sub-wavelength Nanopillars

Abstract

Photonic-crystal (PC) slabs composed of subwavelength silicon pillars erected on a thin silicon backing layer, with heights of only one or half lattice constant, are simulated for optical biosensing by numerical solution of Maxwell's equations. Localized optical cavity modes that form waveguides in the direction of biofluid flow, with quality factors surpassing 104, are embedded within the 2D photonic band gap of the 3D structure. Remarkable sensitivity to analyte binding is achieved using fragmented thin silicon pillars in regions of maximum localized optical-field intensity. Exceptional quality factors are realized through destructive wave interference of vertical radiation loss. This provides a rare combination of high sensitivity and low limit of detection in a device with minimal time requirement for analyte binding. The sensitivity to analyte binding is a frequency shift of nearly 0.004 [2πc/a] per analyte-thickness increment 0.1a. The sensitivity to background biofluid change is about 4800 nm per refractive index unit (RIU) for a specific lattice constant a = 5 μm using light of wavelength 16.5 μm.

Related

  1. Wavelength-selective second-harmonic splitting and focusing in engineered χ ⁽²⁾ photonic crystals
    Zongheng Cui, Tianxiang Xu, Shan Liu +2
    Optics ExpressPeer-reviewedCC BY 4.0Optics & photonicsCrossref
  2. Ultra-low loss piezo-optomechanical low-confinement silicon nitride platform for visible wavelength quantum photonic circuits
    Mayank Mishra, Gwangho Choi, Wenhua He +7
    Nature CommunicationsPeer-reviewedCC BY 4.0Full text1 citedOptics & photonicsCrossref
  3. Automated mode-aware design of nonlinear photonic crystal cavities for intrinsic second harmonic generation
    Yu Huang, Chunlei Qu, Michael Zabarankin +1
    Optics ExpressPeer-reviewedLicence not statedOptics & photonicsCrossref
  4. A Universal Scaling Approach for Transferring Optomechanical and One-Dimensional Photonic Crystal Designs Across Material Platforms
    Berke Demiralp, Nien-Hsuan Lee, Eva Weig
    Optics ExpressPeer-reviewedLicence not statedOptics & photonicsCrossref
  5. Oscillator-driven broadband femtosecond transient microspectroscopy with supercontinuum probes generated in a photonic crystal fiber
    Rikuto Fukuda, Kyosuke Kishihata, Ryo Man-nami +4
    Optics ExpressPeer-reviewedPublisher termsOptics & photonicsCrossref
BibTeX
@misc{zhai2026highperformance,
  title = {{High-Performance Photonic Crystal Biosensors using Sub-wavelength Nanopillars}},
  author = {Zhengzheng Zhai and Sajeev John},
  howpublished = {arXiv},
  year = {2026},
  month = sep,
  doi = {10.48550/arxiv.2609.04656},
  eprint = {2609.04656},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2609.04656},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - High-Performance Photonic Crystal Biosensors using Sub-wavelength Nanopillars
AU  - Zhengzheng Zhai
AU  - Sajeev John
PY  - 2026
DA  - 2026/09/04
PB  - arXiv
DO  - 10.48550/arxiv.2609.04656
UR  - https://arxiv.org/abs/2609.04656
AB  - Photonic-crystal (PC) slabs composed of subwavelength silicon pillars erected on a thin silicon backing layer, with heights of only one or half lattice constant, are simulated for optical biosensing by numerical solution of Maxwell's equations. Localized optical cavity modes that form waveguides in the direction of biofluid flow, with quality factors surpassing 10^4, are embedded within the 2D photonic band gap of the 3D structure. Remarkable sensitivity to analyte binding is achieved using fragmented thin silicon pillars in regions of maximum localized optical-field intensity. Exceptional quality factors are realized through destructive wave interference of vertical radiation loss. This provides a rare combination of high sensitivity and low limit of detection in a device with minimal time requirement for analyte binding. The sensitivity to analyte binding is a frequency shift of nearly 0.004 [2πc/a] per analyte-thickness increment 0.1a. The sensitivity to background biofluid change is about 4800 nm per refractive index unit (RIU) for a specific lattice constant a = 5 μm using light of wavelength 16.5 μm.
ER  -