Skip to content
DraconiticResearch
Search Sources API
277,308 studies31 sourcesUpdated 22 min ago
Peer-reviewedCC BYAnnals of Biomedical Engineering

Deep Learning-Based Assessment of Sleepiness from Fingertip Pulse Wave Analysis During Objective Daytime Testing

Abstract

PURPOSE: Objective evaluation of daytime sleepiness is a key factor in the management of sleep disorders. However, objective testing is limited due to the labor-intensive nature of standard methods; the Multiple Sleep Latency Test (MSLT) and the Maintenance of Wakefulness Test (MWT). Deep learning analysis of a simple fingertip pulse wave (photoplethysmography, PPG) recording could be a viable option for the routine assessment of sleepiness in patients with suspected sleep disorders. METHODS: A deep learning-based sleep staging model was tested in MSLT (n = 143) and MWT (n = 127) datasets. The primary aim was to analyze the classification of subjects as sleepy versus non-sleepy using PPG-based sleep analysis. As an intermediate technical evaluation, we assessed PPG-based sleep-wake classification and mean sleep latency (MSL). RESULTS: Classification of sleepiness status based on automatic MSL detection from PPG showed promising results in both MSLT (accuracy: 80%, sensitivity: 65%, specificity: 84%) and MWT (accuracy: 83%, sensitivity: 62%, specificity: 86%). Sleep probability curves estimated from the fingertip pulse wave differed significantly between sleepy and non-sleepy groups, both in MSLT (p = 0.0002) and in MWT (p = 0.0012) datasets. In MSLT, the model detected sleep with moderate agreement and balanced performance (accuracy 81%, precision 0.71, recall 0.80). In MWT, overall accuracy (88%) was strongly influenced by class imbalance (98% wakefulness), and direct second-by-second sleep detection showed limited precision (precision 0.10, recall 0.72). Automated MSL estimates showed correlation with manual scoring in both MSLT and MWT; however, larger errors and outliers were observed in MWT. CONCLUSION: Fingertip pulse wave analysis combined with deep learning shows feasibility for automated assessment of daytime sleepiness, particularly in MSLT. However, direct zero-shot application of a model trained on overnight PSG to MWT is limited by low sleep precision requiring methodological adaptation and daytime-specific optimization.

Related

  1. Sodium oxybate for excessive daytime sleepiness in narcolepsy: a systematic review and meta-analysis of randomized placebo-controlled trials
    Preeti Kanawjia, Surendra Kumar Kanaujia, Renu Kumari
    DARU Journal of Pharmaceutical SciencesPeer-reviewedLicence not statedFull textNeurosciencePMC
  2. Insomnia versus daytime sleepiness: distinct behavioural phenotypes of mood and binge eating in adults with clinical obesity
    Antoine Avignon, Sarah Tournayre, Catherine Boegner +5
    International Journal of ObesityPeer-reviewedLicence not statedFull textGeneral biologyHAL
  3. Excessive daytime sleepiness caused by multiple focal strokes in thalamus, hypothalamus, and Edinger-Westphal nucleus: a case report.
    Yanan Zhang, Ruiqi Wang, Qingqing Sun +3
    BMC neurologyPeer-reviewedCC BY-NC-NDFull textNeuroscienceEurope PMCPMC
  4. P065. Understanding daytime sleepiness in children with Prader-Willi syndrome
    B Hopkins, G Plunkett, Y Ao +7
    Sleep advances : a journal of the Sleep Research SocietyPeer-reviewedCC BY-NC-NDFull textNeuroscienceEurope PMCPMC
  5. Objective assessment and virtual lesion simulation of psoriasis lesion severity based on deep learning regression and generative models.
    Liuyan Zhu, Zhuoran Ma, Haotian Qian +2
    Frontiers in medicinePeer-reviewedCC BYFull textImmunologyEurope PMCPMC
BibTeX
@article{rusanen2026deep,
  title = {{Deep Learning-Based Assessment of Sleepiness from Fingertip Pulse Wave Analysis During Objective Daytime Testing}},
  author = {Matias Rusanen and Samu Kainulainen and Sami Myllymaa and Timo Leppänen and Renaud Tamisier and Sébastien Baillieul and Sébastien Bailly and Jean-Louis Pepin},
  journal = {Annals of Biomedical Engineering},
  year = {2026},
  month = sep,
  doi = {10.1007/s10439-026-04393-2},
  url = {https://hal.science/hal-05874376v1},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Deep Learning-Based Assessment of Sleepiness from Fingertip Pulse Wave Analysis During Objective Daytime Testing
AU  - Matias Rusanen
AU  - Samu Kainulainen
AU  - Sami Myllymaa
AU  - Timo Leppänen
AU  - Renaud Tamisier
AU  - Sébastien Baillieul
AU  - Sébastien Bailly
AU  - Jean-Louis Pepin
PY  - 2026
DA  - 2026/09/28
JO  - Annals of Biomedical Engineering
DO  - 10.1007/s10439-026-04393-2
UR  - https://hal.science/hal-05874376v1
AB  - PURPOSE: Objective evaluation of daytime sleepiness is a key factor in the management of sleep disorders. However, objective testing is limited due to the labor-intensive nature of standard methods; the Multiple Sleep Latency Test (MSLT) and the Maintenance of Wakefulness Test (MWT). Deep learning analysis of a simple fingertip pulse wave (photoplethysmography, PPG) recording could be a viable option for the routine assessment of sleepiness in patients with suspected sleep disorders. METHODS: A deep learning-based sleep staging model was tested in MSLT (n = 143) and MWT (n = 127) datasets. The primary aim was to analyze the classification of subjects as sleepy versus non-sleepy using PPG-based sleep analysis. As an intermediate technical evaluation, we assessed PPG-based sleep-wake classification and mean sleep latency (MSL). RESULTS: Classification of sleepiness status based on automatic MSL detection from PPG showed promising results in both MSLT (accuracy: 80%, sensitivity: 65%, specificity: 84%) and MWT (accuracy: 83%, sensitivity: 62%, specificity: 86%). Sleep probability curves estimated from the fingertip pulse wave differed significantly between sleepy and non-sleepy groups, both in MSLT (p = 0.0002) and in MWT (p = 0.0012) datasets. In MSLT, the model detected sleep with moderate agreement and balanced performance (accuracy 81%, precision 0.71, recall 0.80). In MWT, overall accuracy (88%) was strongly influenced by class imbalance (98% wakefulness), and direct second-by-second sleep detection showed limited precision (precision 0.10, recall 0.72). Automated MSL estimates showed correlation with manual scoring in both MSLT and MWT; however, larger errors and outliers were observed in MWT. CONCLUSION: Fingertip pulse wave analysis combined with deep learning shows feasibility for automated assessment of daytime sleepiness, particularly in MSLT. However, direct zero-shot application of a model trained on overnight PSG to MWT is limited by low sleep precision requiring methodological adaptation and daytime-specific optimization.
SN  - 0090-6964
SN  - 1573-9686
ER  -