Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 21 min ago
PreprintarXiv licencearXiv

Adaptive Robust Optimisation for Frequency-Constrained Market Clearing Problem

Abstract

This paper formulates the day-ahead market clearing as a two-stage adaptive robust optimisation problem in which the first stage determines unit commitment, energy dispatch, and reserve procurement, while the second stage represents worst-case balancing actions under simultaneous uncertainty in renewable generation, load, and HVDC converter outages. Frequency security is enforced explicitly through inertia and fast frequency response constraints at the synchronous-area level, with HVDC lines allowed to provide emergency power support within their available headroom. The resulting min--max--min problem is solved by a column-and-constraint generation algorithm and applied to an eight-country North Sea test system comprising three synchronous areas, sixteen onshore bidding zones, and five offshore wind farm hubs connected through a meshed HVDC grid. We compare the Home Market (HM) and Offshore Bidding Zone (OBZ) designs on this infrastructure across different uncertainty scenarios. The results first demonstrate the value of robustness, where deterministic solutions that ignore uncertainty are severely vulnerable to worst-case realisations. Comparing the two designs, we find that OBZ's offshore zone boundaries make line congestion visible to the day-ahead market, enabling targeted reserve procurement that raises day-ahead costs but substantially reduces real-time load shedding, yielding a net reduction in total system cost that grows with the severity of localised offshore uncertainty. When both designs face the identical worst-case contingency, HM cannot distinguish an offshore converter trip from normal operation and thus fails to hedge against it, while OBZ considers the risk at the day-ahead stage. This advantage can be seasonal, scaling with the ratio of offshore wind output to HVDC line capacity and diminishing when onshore generation dominates the supply mix.

Related

  1. First- and second-order constrained optimisation for inverse homogenisation of unidirectionally varying microstructure
    Constantin Christof, Malte A. Peter, Michael Ulbrich
    arXivPreprintarXiv licenceFull textAnalysis & PDEsNumerical analysis & scientific computingarXiv
  2. KKT Residual Sliding Manifolds: A Projection-Free Structured Finite-Time Solver for Nonlinear Constrained Optimisation
    Abdelhafid Zenati, Kamal Youcef-Toumi
    arXivPreprintarXiv licenceFull textNumerical analysis & scientific computingOptimisation & controlarXiv
  3. Adaptive Node Distribution via Probability Density Functions for Birkhoff Pseudospectral Trajectory Optimisation
    Andrian A. Yasintus, Xiaofeng Wu
    arXivPreprintCC BY 4.0Full textOptimisation & controlarXiv
  4. StePPO: Adaptive Step-Size Control for Initial-Value Problems Using Proximal Policy Optimisation
    Milan Koumans, Nicola Pezzotti, Tristan S. W. Stevens
    arXivPreprintCC BY 4.0Full textNumerical analysis & scientific computingComputational physicsarXiv
  5. Constrained Capacity for Faster-than-Nyquist Signaling in Frequency-Selective Fading Channels
    Zichao Zhang, Melda Yuksel, Gokhan M. Guvensen +1
    arXivPreprintarXiv licenceFull textGeneral mathematicsarXiv
BibTeX
@misc{mahmutogulları2026adaptive,
  title = {{Adaptive Robust Optimisation for Frequency-Constrained Market Clearing Problem}},
  author = {Özlem Mahmutoğulları and Hakan Ergun},
  howpublished = {arXiv},
  year = {2026},
  month = nov,
  doi = {10.48550/arxiv.2611.31572},
  eprint = {2611.31572},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.31572},
}
RIS
TY  - UNPB
TI  - Adaptive Robust Optimisation for Frequency-Constrained Market Clearing Problem
AU  - Özlem Mahmutoğulları
AU  - Hakan Ergun
PY  - 2026
DA  - 2026/11/23
PB  - arXiv
DO  - 10.48550/arxiv.2611.31572
UR  - https://arxiv.org/abs/2611.31572
AB  - This paper formulates the day-ahead market clearing as a two-stage adaptive robust optimisation problem in which the first stage determines unit commitment, energy dispatch, and reserve procurement, while the second stage represents worst-case balancing actions under simultaneous uncertainty in renewable generation, load, and HVDC converter outages. Frequency security is enforced explicitly through inertia and fast frequency response constraints at the synchronous-area level, with HVDC lines allowed to provide emergency power support within their available headroom. The resulting min--max--min problem is solved by a column-and-constraint generation algorithm and applied to an eight-country North Sea test system comprising three synchronous areas, sixteen onshore bidding zones, and five offshore wind farm hubs connected through a meshed HVDC grid. We compare the Home Market (HM) and Offshore Bidding Zone (OBZ) designs on this infrastructure across different uncertainty scenarios. The results first demonstrate the value of robustness, where deterministic solutions that ignore uncertainty are severely vulnerable to worst-case realisations. Comparing the two designs, we find that OBZ's offshore zone boundaries make line congestion visible to the day-ahead market, enabling targeted reserve procurement that raises day-ahead costs but substantially reduces real-time load shedding, yielding a net reduction in total system cost that grows with the severity of localised offshore uncertainty. When both designs face the identical worst-case contingency, HM cannot distinguish an offshore converter trip from normal operation and thus fails to hedge against it, while OBZ considers the risk at the day-ahead stage. This advantage can be seasonal, scaling with the ratio of offshore wind output to HVDC line capacity and diminishing when onshore generation dominates the supply mix.
ER  -