Accurate determination of the refractive index in biological tissues using limited-angle optical diffraction tomography: a case study on mouse retina
8 affiliations
- 1Institute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University in Toruń, Grudziądzka 5, 87-100 Toruń, Poland.
- 2Warsaw University of Technology, Institute of Micromechanics and Photonics, Boboli 8 street, Warsaw, 02-525, Poland.
- 3Institute of Biology, Faculty of Biological and Veterinary Sciences, Nicolaus Copernicus University in Toruń, Lwowska 1, 87-100 Toruń, Poland.
- 4Independent researcher, Poland.
- 5Institute of Advanced Studies, Nicolaus Copernicus University in Toruń, Wileńska 4, 87-100 Toruń, Poland.
- 6BRITElab, Harry Perkins Institute of Medical Research, QEII Medical Centre, Nedlands and Centre for Medical Research, The University of Western Australia, Crawley, WA 6009, Australia.
- 7Department of Electrical, Electronic & Computer Engineering, School of Engineering, The University of Western Australia, Crawley, WA 6009, Australia.
- 8Department of Medical Physics and Biomedical Imaging, University College London, London, WC1E 6BT, United Kingdom.
Abstract
We present a comprehensive framework for quantitative refractive index (RI) determination in biological tissues using limited-angle optical diffraction tomography (LA-ODT), combining immersion matching, missing-cone error correction based on optical volume conservation, and layer-specific fill-factor analysis. This approach is demonstrated on the mouse retina, yielding accurate mean RI values for eight retinal layers under hydrated (PBS) conditions, and the RI distribution of non-aqueous tissue components. Comparison of formalin-fixed, paraffin-embedded (FFPE) specimens and frozen sections revealed no significant RI bias induced by FFPE processing. The proposed methodology provides a robust, quantitative, and transferable framework for RI characterization in diverse biological tissues.
Related
- Complex Refractive Index Determination via Microspectroscopy Through Magnifying Optics: Challenges and Opportunities
- X2SBench: an open benchmark for evaluating crystal structure determination from powder diffraction
- Accurate Morphology-Related Diffraction Behavior of Light-Induced Surface Relief Gratings on Azopolymers
- Fluorescence-illuminated diffraction tomography using explicit neural fields
- Accurate Molecular Size Determination by Diffusion Ordered NMR Spectroscopy Based on an Improved Diffusion Model
BibTeX
@article{ossowski2026accurate,
title = {{Accurate determination of the refractive index in biological tissues using limited-angle optical diffraction tomography: a case study on mouse retina}},
author = {Paweł Ossowski and Michał Ziemczonok and Łukasz Kuźbicki and Paulina Trzeciak and Szymon Tamborski and Anna Nowakowska and Brendan F Kennedy and Peter R T Munro and Maciej Szkulmowski},
journal = {Biomedical optics express},
year = {2026},
month = oct,
doi = {10.1364/boe.606775},
url = {https://europepmc.org/article/PMC/PMC13795937},
note = {CC BY},
}
RIS
TY - JOUR
TI - Accurate determination of the refractive index in biological tissues using limited-angle optical diffraction tomography: a case study on mouse retina
AU - Paweł Ossowski
AU - Michał Ziemczonok
AU - Łukasz Kuźbicki
AU - Paulina Trzeciak
AU - Szymon Tamborski
AU - Anna Nowakowska
AU - Brendan F Kennedy
AU - Peter R T Munro
AU - Maciej Szkulmowski
PY - 2026
DA - 2026/10/07
JO - Biomedical optics express
DO - 10.1364/boe.606775
UR - https://europepmc.org/article/PMC/PMC13795937
AB - We present a comprehensive framework for quantitative refractive index (RI) determination in biological tissues using limited-angle optical diffraction tomography (LA-ODT), combining immersion matching, missing-cone error correction based on optical volume conservation, and layer-specific fill-factor analysis. This approach is demonstrated on the mouse retina, yielding accurate mean RI values for eight retinal layers under hydrated (PBS) conditions, and the RI distribution of non-aqueous tissue components. Comparison of formalin-fixed, paraffin-embedded (FFPE) specimens and frozen sections revealed no significant RI bias induced by FFPE processing. The proposed methodology provides a robust, quantitative, and transferable framework for RI characterization in diverse biological tissues.
SN - 2156-7085
ER -