Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 22 min ago
Peer-reviewedCC BY 4.0PLOS One

Evaluating the acceptability of virtual reality visual field testing in rural Virginia

1 more authors
  1. 1Virginia Commonwealth University School of Medicine, Richmond, Virginia, United States of America
  2. 2Department of Biostatistics, Virginia Commonwealth University, Richmond, Virginia, United States of America
  3. 3Department of Ophthalmology, Virginia Commonwealth University, Richmond, Virginia, United States of America

Abstract

Objective: To evaluate the acceptability of virtual reality (VR)-based visual field (VF) testing using the RetinaLogik Virtual Reality Headset Perimeter (RVF100) device in rural Virginia. Methods: We conducted a cross-sectional study at Remote Area Medical (RAM) vision clinics in medically underserved areas of rural Virginia. Participants were 99 adults (198 eyes) aged 18 years or older with a best-corrected visual acuity of 20/200 or better in both eyes. Participants completed VF testing using the RVF100. Acceptability was assessed using the System Usability Scale (SUS), supplemented by measures of willingness to retest, dizziness or discomfort, and test completion. SUS scores were summarized descriptively and analyzed using a Gaussian generalized linear model with a log-link to examine associations with prespecified covariates. Results: The median SUS score was 80.00 (A− grade, 85th–89th percentile). Willingness to retest was reported by 90/99 participants (90.9%; Wilson 95% CI, 83.6%–95.1%), 75/99 felt confident using the device (75.8%; Wilson 95% CI, 66.5%–83.1%), and 16/99 reported dizziness or discomfort (16.2%; Wilson 95% CI, 10.2%–24.7%). All 99 participants completed testing (100.0%; Wilson 95% CI, 96.3%–100.0%). Median pattern standard deviation was 1.51 dB in the right eye and 1.47 dB in the left eye; median mean deviation was −0.49 dB in both eyes, and median bilateral assessment duration was 4.78 minutes. No prespecified regression predictor met α = 0.05. Conclusions: VR-based VF testing was well accepted by participants attending rural outreach clinics and was feasible within the outreach workflow. These findings are limited to patient acceptability in a relatively young cohort in which pre-existing ocular disease and visual field status were not systematically characterized. They do not establish diagnostic accuracy or clinical effectiveness, which require direct comparison with standard automated perimetry in the populations for whom perimetry is indicated.

Related

  1. Feasibility, acceptability, and preliminary efficacy of AdaptRehab VR, an immersive virtual reality system for upper limb stroke rehabilitation: A mixed-methods study in Ethiopia
    Chala Diriba Kenea, Teklu Gemechu Abessa, Dheeraj Lamba +1
    PLOS OnePeer-reviewedCC BY 4.0Full textNeuroscienceNeurologyPLOS
  2. Testing Socio-Perceptual Equigenesis with Biophilic Interventions: A Virtual Reality Eye-Tracking Study Across Neighborhood Socioeconomic Status
    Paula Latorre, Cleiton Pons Ferreira, Aurora Molina-Muñoz +3
    PsyArXivPreprintCC BY 4.0Full textNeuroscienceOSF
  3. Investigation of human defence responses in a virtual reality environment: an EEG study
    Vidisha Maithani, Manish Kumar Asthana
    Frontiers in human neurosciencePeer-reviewedCC BYFull textNeuroscienceEurope PMC
  4. Beyond heartbeats: re-thinking interoception in autism through virtual reality and computational modelling
    Sarune Savickaite, Ruichen Li, Yukie Nagai
    Frontiers in neural circuitsPeer-reviewedCC BYFull textNeuroscienceEurope PMC
  5. An EMG-driven virtual reality platform for physiology-based motor interaction: technical and functional validation
    V. Betti, M. Marucci, C. Perciballi +2
    Frontiers in human neurosciencePeer-reviewedCC BYFull textNeuroscienceEurope PMC
BibTeX
@article{selvan2026evaluating,
  title = {{Evaluating the acceptability of virtual reality visual field testing in rural Virginia}},
  author = {Kavin Selvan and Brandon Rinkavage and Nancy Beinlich and Sarah Abouassali and Michelle Lam and Victoria Wu and Omar Al-Dulaimi and Amanda Robinson and Du Cheng and Evan Silverstein and Mary K. Daly and Roy Sabo and Surbhi Bansal},
  journal = {PLOS One},
  year = {2026},
  month = nov,
  doi = {10.1371/journal.pone.0361218},
  url = {https://doi.org/10.1371/journal.pone.0361218},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Evaluating the acceptability of virtual reality visual field testing in rural Virginia
AU  - Kavin Selvan
AU  - Brandon Rinkavage
AU  - Nancy Beinlich
AU  - Sarah Abouassali
AU  - Michelle Lam
AU  - Victoria Wu
AU  - Omar Al-Dulaimi
AU  - Amanda Robinson
AU  - Du Cheng
AU  - Evan Silverstein
AU  - Mary K. Daly
AU  - Roy Sabo
AU  - Surbhi Bansal
PY  - 2026
DA  - 2026/11/25
JO  - PLOS One
DO  - 10.1371/journal.pone.0361218
UR  - https://doi.org/10.1371/journal.pone.0361218
AB  - Objective: To evaluate the acceptability of virtual reality (VR)-based visual field (VF) testing using the RetinaLogik Virtual Reality Headset Perimeter (RVF100) device in rural Virginia. Methods: We conducted a cross-sectional study at Remote Area Medical (RAM) vision clinics in medically underserved areas of rural Virginia. Participants were 99 adults (198 eyes) aged 18 years or older with a best-corrected visual acuity of 20/200 or better in both eyes. Participants completed VF testing using the RVF100. Acceptability was assessed using the System Usability Scale (SUS), supplemented by measures of willingness to retest, dizziness or discomfort, and test completion. SUS scores were summarized descriptively and analyzed using a Gaussian generalized linear model with a log-link to examine associations with prespecified covariates. Results: The median SUS score was 80.00 (A− grade, 85th–89th percentile). Willingness to retest was reported by 90/99 participants (90.9%; Wilson 95% CI, 83.6%–95.1%), 75/99 felt confident using the device (75.8%; Wilson 95% CI, 66.5%–83.1%), and 16/99 reported dizziness or discomfort (16.2%; Wilson 95% CI, 10.2%–24.7%). All 99 participants completed testing (100.0%; Wilson 95% CI, 96.3%–100.0%). Median pattern standard deviation was 1.51 dB in the right eye and 1.47 dB in the left eye; median mean deviation was −0.49 dB in both eyes, and median bilateral assessment duration was 4.78 minutes. No prespecified regression predictor met α = 0.05. Conclusions: VR-based VF testing was well accepted by participants attending rural outreach clinics and was feasible within the outreach workflow. These findings are limited to patient acceptability in a relatively young cohort in which pre-existing ocular disease and visual field status were not systematically characterized. They do not establish diagnostic accuracy or clinical effectiveness, which require direct comparison with standard automated perimetry in the populations for whom perimetry is indicated.
SN  - 1932-6203
ER  -