Skip to content
DraconiticResearch
Search Sources API
186,086 studies31 sourcesUpdated just now
PreprintarXiv licencearXiv

The Magnetic-Resonance-Based, Omni-Directional Hydrophone

Abstract

This study aims to improve the directional sensitivity of magnetic resonance hydrophone (MRH) methods and allow for detection and quantification of waves traveling at any angle relative to the MRI bore-axis. Doing so may better integrate MRH technology into transcranial focused ultrasound neuromodulation therapies. Existing MRH implementations only encode acoustic waves propagating along the MRI bore-axis, precluding use with wide aperture transducers or temporal skull windows. This study expands the MRH technique into a MR-based Omni-directional Hydrophone (MRbOH) that can quantify the magnitude pressure and phase of waves propagating at any angle. The MRbOH method formulates a system of equations around uniquely sensitized images that, when solved, introduce sensitivity to oblique acoustic waves. The method was tested experimentally in a gel phantom that was insonated at 0o, 45o, and 90o relative to the MRI bore-axis. The method reconstructed pressure maps at all three angles of propagation, including features such as peak pressure, partial reflections, and beamwidth. The MRbOH method measured an average beamwidth of 16.2 mm while the hydrophone measured a beamwidth of 14.5 mm. Average hydrophone-measured pressure within a region of interest was 416.19 ± 78.07 kPa. Average MRbOH measured pressure in the same region at 0o, 45o, and 90o, respectively, were: 285.5 ± 49.5 kPa, 193.13 ± 43.55 kPa, 194.7 ± 47.38 kPa. In addition, the study presents and experimentally verifies a statistical noise model that predicted the mean with R2 = 0.85, and standard deviation with R2 = 0.83.

Related

  1. Near-infrared magnetic linear and non-reciprocal directional dichroism in the chiral antiferromagnet SmFe3(BO3)4
    B. Beke, B. Szász, I. A. Gudim +2
    arXivPreprintarXiv licenceFull textCondensed matterarXiv
  2. Mechanism of Incommensurate Magnetic Order in BaCo2(AsO4)2: Interplay of Frustrated Further-Neighbor Exchanges and Bond-Directional Anisotropy
    Mohammad-Hossein Zare, Mehdi Biderang, Hamid Mosadeq
    arXivPreprintCC BY-NC-SA 4.0Full textCondensed matterarXiv
  3. Nuclear magnetic resonance on a single atom with a local probe
    Hester G. Vennema, Cristina Mier, Evert W. Stolte +3
    Nature CommunicationsPeer-reviewedCC BY-NC-ND 4.0Full textAtomic, molecular & optical physicsCrossref
  4. Comparative Assessment of Graglia-Wilton-Peterson and Rao-Wilton-Glisson Basis Functions for Radiofrequency Coil Modeling in Magnetic Resonance Imaging
    Damiano Franzò, Ilias Giannakopoulos, Adrien Merlini +2
    IEEE Journal on Multiscale and Multiphysics Computational TechniquesPeer-reviewedLicence not statedComputational physicsHAL
  5. Unimodality and Radial Monotonicity of the Magnetic Resonance Fingerprinting T1/T2 Matching Objective
    Ze Wang
    arXivPreprintCC BY-NC-ND 4.0Full textBiological & medical physicsComputational physicsarXiv
BibTeX
@misc{thyberg2026magneticresonancebased,
  title = {{The Magnetic-Resonance-Based, Omni-Directional Hydrophone}},
  author = {Nathan Thyberg and Davi Cavinatto and Katia Oler and Elijah Oxborrow and Hyrum Mangum and Steven P. Allen},
  howpublished = {arXiv},
  year = {2026},
  month = sep,
  doi = {10.48550/arxiv.2609.17793},
  eprint = {2609.17793},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2609.17793},
}
RIS
TY  - UNPB
TI  - The Magnetic-Resonance-Based, Omni-Directional Hydrophone
AU  - Nathan Thyberg
AU  - Davi Cavinatto
AU  - Katia Oler
AU  - Elijah Oxborrow
AU  - Hyrum Mangum
AU  - Steven P. Allen
PY  - 2026
DA  - 2026/09/15
PB  - arXiv
DO  - 10.48550/arxiv.2609.17793
UR  - https://arxiv.org/abs/2609.17793
AB  - This study aims to improve the directional sensitivity of magnetic resonance hydrophone (MRH) methods and allow for detection and quantification of waves traveling at any angle relative to the MRI bore-axis. Doing so may better integrate MRH technology into transcranial focused ultrasound neuromodulation therapies. Existing MRH implementations only encode acoustic waves propagating along the MRI bore-axis, precluding use with wide aperture transducers or temporal skull windows. This study expands the MRH technique into a MR-based Omni-directional Hydrophone (MRbOH) that can quantify the magnitude pressure and phase of waves propagating at any angle. The MRbOH method formulates a system of equations around uniquely sensitized images that, when solved, introduce sensitivity to oblique acoustic waves. The method was tested experimentally in a gel phantom that was insonated at 0^o, 45^o, and 90^o relative to the MRI bore-axis. The method reconstructed pressure maps at all three angles of propagation, including features such as peak pressure, partial reflections, and beamwidth. The MRbOH method measured an average beamwidth of 16.2 mm while the hydrophone measured a beamwidth of 14.5 mm. Average hydrophone-measured pressure within a region of interest was 416.19 ± 78.07 kPa. Average MRbOH measured pressure in the same region at 0^o, 45^o, and 90^o, respectively, were: 285.5 ± 49.5 kPa, 193.13 ± 43.55 kPa, 194.7 ± 47.38 kPa. In addition, the study presents and experimentally verifies a statistical noise model that predicted the mean with R^2 = 0.85, and standard deviation with R^2 = 0.83.
ER  -