Repurposing acquisition devices into trigger-based timing synchronization of breakdown events during MITICA high voltage holding experiments
Abstract
A critical requirement for MITICA -- a full-scale prototype of the heating Neutral Beam Injectors hosted at the Consorzio RFX Neutral Beam Test Facility for the ITER experiment -- is the capability to withstand a continuous voltage of 1MV across the vacuum gaps insulating the beam source from the grounded vessel. To validate such feature, a dedicated voltage-holding test campaign was conducted throughout 2024 and 2025 using a full-scale mock-up of the beam source. The tests also involved an accurate characterization of the associated breakdown events: vacuum dielectric failures which result in rapid potential drops and generate strong current discharges. This contribution will present a relative time reconstruction architecture based on cost-effective, embedded RedPitaya (Zynq-7000 FPGA) devices repurposed as timing hubs. These nodes function as configurable trigger multiplexers while simultaneously recording trigger signals as transients to facilitate the offline reconstruction of event sequences. The method allows self-calibration through measuring the static intrinsic delays of the optical fibers and internal logics, generating delay offsets to synchronize acquired waveforms across a sparse, connected-graph topology of both acquisition devices and hubs themselves.
Related
- Breakdown of Adiabatic Scaling and Noise-induced Functional Synchronization in Deeply Quiescent Excitable Systems
- Remote synchronization and critical-like breakdown in star networks of oscillator populations
- Breakdown of the Wiedemann-Franz Law in an Interacting Quantum Hall Metamaterial
- Non-reciprocity and exchange-spring delay of domain-wall Walker breakdown in magnetic nanowires with azimuthal magnetization
- Synchronization Threshold and Stability of Heterogeneous Josephson-Junction Arrays with Nonsymmetric Weighted Coupling
BibTeX
@misc{garola2026repurposing,
title = {{Repurposing acquisition devices into trigger-based timing synchronization of breakdown events during MITICA high voltage holding experiments}},
author = {Andrea Rigoni Garola and Luca Lotto and Gabriele Manduchi and Tommaso Patton and Raffaele Ghiraldelli and Cesare Taliercio and Marco Boldrin and Luca Trevisan and Paolo Cinetto and Paolo Barbato and Giuseppe Chitarin},
howpublished = {arXiv},
year = {2026},
month = oct,
doi = {10.48550/arxiv.2607.08501},
eprint = {2607.08501},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2607.08501},
note = {CC BY 4.0},
}
RIS
TY - UNPB
TI - Repurposing acquisition devices into trigger-based timing synchronization of breakdown events during MITICA high voltage holding experiments
AU - Andrea Rigoni Garola
AU - Luca Lotto
AU - Gabriele Manduchi
AU - Tommaso Patton
AU - Raffaele Ghiraldelli
AU - Cesare Taliercio
AU - Marco Boldrin
AU - Luca Trevisan
AU - Paolo Cinetto
AU - Paolo Barbato
AU - Giuseppe Chitarin
PY - 2026
DA - 2026/10/20
PB - arXiv
DO - 10.48550/arxiv.2607.08501
UR - https://arxiv.org/abs/2607.08501
AB - A critical requirement for MITICA -- a full-scale prototype of the heating Neutral Beam Injectors hosted at the Consorzio RFX Neutral Beam Test Facility for the ITER experiment -- is the capability to withstand a continuous voltage of 1MV across the vacuum gaps insulating the beam source from the grounded vessel. To validate such feature, a dedicated voltage-holding test campaign was conducted throughout 2024 and 2025 using a full-scale mock-up of the beam source. The tests also involved an accurate characterization of the associated breakdown events: vacuum dielectric failures which result in rapid potential drops and generate strong current discharges. This contribution will present a relative time reconstruction architecture based on cost-effective, embedded RedPitaya (Zynq-7000 FPGA) devices repurposed as timing hubs. These nodes function as configurable trigger multiplexers while simultaneously recording trigger signals as transients to facilitate the offline reconstruction of event sequences. The method allows self-calibration through measuring the static intrinsic delays of the optical fibers and internal logics, generating delay offsets to synchronize acquired waveforms across a sparse, connected-graph topology of both acquisition devices and hubs themselves.
ER -