Fast computational screening of extrusion parameters for bioprinting of skeletal myoblasts in alginate hydrogel

  1. 1University of Bari Aldo Moro

Abstract

Background: Real-time selection of extrusion bioprinting parameters requires rapid prediction of an operating window that balances material throughput against mechanically induced cell damage. Full numerical simulations can resolve the relevant flow mechanics, but their computational cost limits repeated evaluation during process adjustment. In this work, a finite element-Gaussian process (GP) framework is developed for rapid operating-window prediction in skeletal myoblast bioprinting for tissue engineering purposes. Methods: An axisymmetric model of inertia-retained, shear-thinning flow of a 1.5% (w/v) alginate suspension of L8 rat myoblasts is coupled to a previously documented damage law that separates nozzle shear from entrance extensional injury of the same cell model. The dataset comprises 32 combinations of four nozzle diameters (100-330 {micro}m) and eight applied pressures (25-400 kPa). GP surrogates are developed to predict flow rate, wall shear stress and total mechanical damage. Results: GP surrogates respond in under one millisecond per parameter combination, compared with approximately 1.5 hours per finite element case. In leave-one-out validation, the surrogates reproduce the simulated damage with a mean absolute error of 0.34 percentage points and the flow rate with a mean absolute percentage error of 6.8%. With a whole nozzle diameter withheld, the damage error rises to 0.88 percentage points. With screening limits of predicted damage below 20% and a flow rate of at least 1 {micro}L/s, 17 of the 32 simulated conditions lie within the operating window. The damage decomposition also shows the dependency of nozzle selection on the imposed constraint: at 200 kPa, the predicted damage increases from 9.0% to 18.0% with nozzle diameter increasing from 200 {micro}m to 330 {micro}m. The 330 {micro}m nozzle carries a 15.8-fold higher flow rate than the 200 {micro}m nozzle, which raises the effective extensional stress at the nozzle entrance. At a matched flow rate of 1 {micro}L/s, the predicted damage instead decreases from 5.5% to 4.6%. Conclusions: The developed framework supports real-time computational screening of printing parameters within the sampled domain and suggests the need for careful selection of nozzle diameter and applied pressure together, since the ordering of nozzles by predicted damage reverses between fixed pressure and matched flow rate.

Related

  1. Defining a Biofabrication Window for Visible-Light Photocrosslinkable Protein Bioinks in Extrusion Bioprinting
    J. Martin-Perez, S. Martinez-Rodriguez, C. Castro-Dominguez +4
    bioRxivPreprintAll rights reservedFull textSystems & synthetic biologybioRxiv
  2. Modelling and measuring effects of shear stress in extrusion bioprinting of endothelial- epithelial cell co-cultures
    J. W. Davern, A. Weekes, J. Amaya Catano +3
    bioRxivPreprintCC BYFull textSystems & synthetic biologybioRxiv
  3. Proteomics-supported amniotic membrane extract-supplemented GelMA bioink enables extrusion-based 3D bioprinting of hiPSC-derived corneal stromal constructs
    Reem Al Monla, Manon Descieux, Morgane Benard +11
    BioprintingPeer-reviewedCC BY-NC-NDGeneral biologyHAL
  4. Integration of In-Line Light-Mediated Cell Activation in Extrusion-Based Bioprinting: A New Biofabrication Strategy for Bone Tissue Engineering
    S. C. Doettl, A. Malandrino, C. Miller +6
    bioRxivPreprintCC BY-NC-NDFull textSystems & synthetic biologybioRxiv
  5. 3D bioprinting for cancer modeling and drug screening
    Aurélie Cadiou, Eva-Laure Peiller Matera, Nicolas Ellinger +4
    Biomarker ResearchPeer-reviewedCC BY1 citedGeneral biologyHAL
BibTeX
@misc{tavangari2026fast,
  title = {{Fast computational screening of extrusion parameters for bioprinting of skeletal myoblasts in alginate hydrogel}},
  author = {Z. Tavangari and A. Maghami and A. Papangelo and G. G. Genchi},
  howpublished = {bioRxiv},
  year = {2026},
  month = oct,
  doi = {10.64898/2026.10.19.760174},
  url = {https://www.biorxiv.org/content/10.64898/2026.10.19.760174v1},
  note = {CC BY},
}
RIS
TY  - UNPB
TI  - Fast computational screening of extrusion parameters for bioprinting of skeletal myoblasts in alginate hydrogel
AU  - Z. Tavangari
AU  - A. Maghami
AU  - A. Papangelo
AU  - G. G. Genchi
PY  - 2026
DA  - 2026/10/19
PB  - bioRxiv
DO  - 10.64898/2026.10.19.760174
UR  - https://www.biorxiv.org/content/10.64898/2026.10.19.760174v1
AB  - Background: Real-time selection of extrusion bioprinting parameters requires rapid prediction of an operating window that balances material throughput against mechanically induced cell damage. Full numerical simulations can resolve the relevant flow mechanics, but their computational cost limits repeated evaluation during process adjustment. In this work, a finite element-Gaussian process (GP) framework is developed for rapid operating-window prediction in skeletal myoblast bioprinting for tissue engineering purposes. Methods: An axisymmetric model of inertia-retained, shear-thinning flow of a 1.5% (w/v) alginate suspension of L8 rat myoblasts is coupled to a previously documented damage law that separates nozzle shear from entrance extensional injury of the same cell model. The dataset comprises 32 combinations of four nozzle diameters (100-330 {micro}m) and eight applied pressures (25-400 kPa). GP surrogates are developed to predict flow rate, wall shear stress and total mechanical damage. Results: GP surrogates respond in under one millisecond per parameter combination, compared with approximately 1.5 hours per finite element case. In leave-one-out validation, the surrogates reproduce the simulated damage with a mean absolute error of 0.34 percentage points and the flow rate with a mean absolute percentage error of 6.8%. With a whole nozzle diameter withheld, the damage error rises to 0.88 percentage points. With screening limits of predicted damage below 20% and a flow rate of at least 1 {micro}L/s, 17 of the 32 simulated conditions lie within the operating window. The damage decomposition also shows the dependency of nozzle selection on the imposed constraint: at 200 kPa, the predicted damage increases from 9.0% to 18.0% with nozzle diameter increasing from 200 {micro}m to 330 {micro}m. The 330 {micro}m nozzle carries a 15.8-fold higher flow rate than the 200 {micro}m nozzle, which raises the effective extensional stress at the nozzle entrance. At a matched flow rate of 1 {micro}L/s, the predicted damage instead decreases from 5.5% to 4.6%. Conclusions: The developed framework supports real-time computational screening of printing parameters within the sampled domain and suggests the need for careful selection of nozzle diameter and applied pressure together, since the ordering of nozzles by predicted damage reverses between fixed pressure and matched flow rate.
ER  -