Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 34 min ago
Peer-reviewedCC BYImaging neuroscience (Cambridge, Mass.)

Minimizing the influence of magnetic vestibular stimulation inside MRI scanners by adjusting head position.

  1. 1Center of Neurology, Division of Neuropsychology, Hertie-Institute for Clinical Brain Research, University of Tübingen, Tübingen, Germany.
  2. 2Department of Psychiatry and Psychotherapy, Tübingen University Clinic, Tübingen, Germany.
  3. 3Department of Psychology, University of South Carolina, Columbia, SC, United States.

Abstract

Magnetic resonance imaging (MRI) offers detailed diagnostic insights but also unintentionally induces vestibular side effects by its static magnetic field. Magnetic vestibular stimulation (MVS) may cause dizziness and confound behavioral and physiological measures in fMRI by introducing an unavoidable mixture of neural activation in vestibular projection areas, driven both by the signal of interest and by vestibular system activation. This study investigated how different head orientations within a 3T MRI scanner influence the MVS-induced vestibulo-ocular reflex (VOR) in complete darkness, with the goal of identifying a head position that minimizes or eliminates MVS effects. Results revealed a linear relationship between head pitch and the horizontal VOR (Experiment 1), as well as between head roll and the vertical VOR (Experiment 2). Across participants, the horizontal VOR was eliminated at a median forward head pitch of 24.4°, while the vertical VOR was nullified at an average roll angle of 15.9° towards the right shoulder. A head position combining this forward pitch with this rightward roll effectively minimized both horizontal and vertical VOR components across subjects (Experiment 3). No conclusions can be drawn regarding torsional eye movements, as those were not recorded. The findings provide a practical solution to reduce the impact of MVS effects in MRI with important implications for improving data quality in neuroscientific fMRI studies and patient comfort during clinical imaging.

Related

  1. Investigating the transfer of physical stimuli to the dreamed body: A comparative study of muscular, vestibular, and haptic stimulation on dream incorporation
    Emma Peters, Jakob Poehlmann, Xinlin Wang +8
    PLOS OnePeer-reviewedCC BY 4.0Full textNeurosciencePhysiologyPLOS
  2. Acute changes in vestibular function and postural control following 100 Hz sound stimulation in patients with vestibular disorders
    Masumi Kobayashi, Tadao Yoshida, Naomi Katayama +4
    Frontiers in NeurologyPeer-reviewedCC BY 4.0NeurologyCrossref
  3. Intraoperative detection of a false-negative facial motor evoked potential by direct facial nerve stimulation during vestibular schwannoma surgery: A case report.
    Masahiro Nonaka, Takeshi Itakura, Katsuya Ueno +6
    Surgical neurology internationalPeer-reviewedCC BY-NC-SAFull textSurgery & anaesthesiaEurope PMCPMC
  4. Acute central metabolic effects of otolithic vestibular stimulation in a non-human primate model of Parkinsonism: proof-of-concept neuroimaging and functional study
    Joan Lorente-Piera, María Collantes, Ángel Ramos de Miguel +9
    Frontiers in NeurologyPeer-reviewedCC BY 4.0Full textNeurologyCrossrefDOAJEurope PMCPMC+1
  5. Vestibular-Cochlear Implant (VICI): Protocol of an exploratory proof-of-principle study on electrical otolith stimulation in Parkinson’s disease
    M. L. Di Carlo Riato, A. J. Beynon, W. J. Huinck +6
    Frontiers in NeurologyPeer-reviewedCC BY 4.0NeurologyCrossref
BibTeX
@article{schaffeld2026minimizing,
  title = {{Minimizing the influence of magnetic vestibular stimulation inside MRI scanners by adjusting head position.}},
  author = {Laura Schaffeld and Leonie Behle and Axel Lindner and Hans-Otto Karnath},
  journal = {Imaging neuroscience (Cambridge, Mass.)},
  year = {2026},
  month = nov,
  doi = {10.1162/imag.a.1440},
  url = {https://europepmc.org/article/MED/43017252},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Minimizing the influence of magnetic vestibular stimulation inside MRI scanners by adjusting head position.
AU  - Laura Schaffeld
AU  - Leonie Behle
AU  - Axel Lindner
AU  - Hans-Otto Karnath
PY  - 2026
DA  - 2026/11/10
JO  - Imaging neuroscience (Cambridge, Mass.)
DO  - 10.1162/imag.a.1440
UR  - https://europepmc.org/article/MED/43017252
AB  - Magnetic resonance imaging (MRI) offers detailed diagnostic insights but also unintentionally induces vestibular side effects by its static magnetic field. Magnetic vestibular stimulation (MVS) may cause dizziness and confound behavioral and physiological measures in fMRI by introducing an unavoidable mixture of neural activation in vestibular projection areas, driven both by the signal of interest and by vestibular system activation. This study investigated how different head orientations within a 3T MRI scanner influence the MVS-induced vestibulo-ocular reflex (VOR) in complete darkness, with the goal of identifying a head position that minimizes or eliminates MVS effects. Results revealed a linear relationship between head pitch and the horizontal VOR (Experiment 1), as well as between head roll and the vertical VOR (Experiment 2). Across participants, the horizontal VOR was eliminated at a median forward head pitch of 24.4°, while the vertical VOR was nullified at an average roll angle of 15.9° towards the right shoulder. A head position combining this forward pitch with this rightward roll effectively minimized both horizontal and vertical VOR components across subjects (Experiment 3). No conclusions can be drawn regarding torsional eye movements, as those were not recorded. The findings provide a practical solution to reduce the impact of MVS effects in MRI with important implications for improving data quality in neuroscientific fMRI studies and patient comfort during clinical imaging.
SN  - 2837-6056
ER  -