On imaging capabilities of the Imaging and Medical beamline at the Australian Synchrotron
Abstract
Several propagation-based and analyser-based X-ray phase-contrast imaging experiments with over 100 m between the imaged objects and the detector were carried out at the Imaging and Medical beamline (IMBL) of the Australian Synchrotron. These experiments were aimed at characterization of possible phase-contrast imaging setups at IMBL. Effects of the beam divergence, polychromaticity and X-ray source size on the contrast and spatial resolution of images were evaluated quantitatively in different imaging scenarios. The results of this work will be used for improving the existing and developing new imaging capabilities at the beamline. Applications to X-ray phase-contrast tomography of biomedical samples, particularly for medical breast cancer imaging, are briefly discussed.
Related
- Measurements of the micro-spill structure of medical cyclotron and synchrotron beams and its impact on pulse pileup
- Rethinking AI in Medical Imaging: Assumptions, Reality, and Reframing; Towards Physician-Centered Agentic Reasoning
- Quantum Machine Learning in Medical Imaging: A Primer for Radiologists
- Automated end-station at the soft X-ray beamline featuring robotic air-to-ultrahigh-vacuum sample transfer, scanning probe spectroscopy, and machine learning analysis
- AnatomIQ: An Open-Source Toolkit for Automated Background Detection in Medical Imaging
BibTeX
@misc{gureyev2026imaging,
title = {{On imaging capabilities of the Imaging and Medical beamline at the Australian Synchrotron}},
author = {T. E. Gureyev and K. M. Pavlov and C. J. Hall and A. Maksimenko and D. Pelliccia and D. M. Paganin and A. W. Stevenson and A. Entezam and H. M. Quiney},
howpublished = {arXiv},
year = {2026},
month = sep,
doi = {10.48550/arxiv.2609.18048},
eprint = {2609.18048},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2609.18048},
note = {CC BY 4.0},
}
RIS
TY - UNPB
TI - On imaging capabilities of the Imaging and Medical beamline at the Australian Synchrotron
AU - T. E. Gureyev
AU - K. M. Pavlov
AU - C. J. Hall
AU - A. Maksimenko
AU - D. Pelliccia
AU - D. M. Paganin
AU - A. W. Stevenson
AU - A. Entezam
AU - H. M. Quiney
PY - 2026
DA - 2026/09/16
PB - arXiv
DO - 10.48550/arxiv.2609.18048
UR - https://arxiv.org/abs/2609.18048
AB - Several propagation-based and analyser-based X-ray phase-contrast imaging experiments with over 100 m between the imaged objects and the detector were carried out at the Imaging and Medical beamline (IMBL) of the Australian Synchrotron. These experiments were aimed at characterization of possible phase-contrast imaging setups at IMBL. Effects of the beam divergence, polychromaticity and X-ray source size on the contrast and spatial resolution of images were evaluated quantitatively in different imaging scenarios. The results of this work will be used for improving the existing and developing new imaging capabilities at the beamline. Applications to X-ray phase-contrast tomography of biomedical samples, particularly for medical breast cancer imaging, are briefly discussed.
ER -