Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 18 min ago
Peer-reviewedCC BYSleep science (Sao Paulo, Brazil)

Metrics Reflecting Cumulative Exposure to Nocturnal Hypoxia Demonstrate Promising Performance in Distinguishing between Moderate and Severe Obstructive Sleep Apnea.

  1. 1Department of Physical Therapy, Centro de Ciências da Saúde, Universidade Federal de Pernambuco, Recife, PEBrazil.
  2. 2Hospital Otávio de Freitas (HOF), Recife, PEBrazil.
  3. 3Department of Physical Therapy, Universidade Federal de Minas Gerais, Belo Horizonte, MGBrazil.

Abstract

The apnea-hypopnea index is traditionally used to classify the severity of obstructive sleep apnea; however, it does not fully capture the cumulative physiological impact of nocturnal hypoxia. Metrics that quantify integrated hypoxic exposure may provide a more accurate characterization of disease severity. The current study compared the independent association and discriminative performance of hypoxic burden, cumulative time with peripheral oxygen saturation below 90%, and oxygen desaturation frequency in distinguishing between moderate and severe obstructive sleep apnea. In total, 30 patients with moderate or severe disease were evaluated using actigraphy combined with continuous nocturnal oximetry. Separate logistic regression models adjusted for body mass index were developed. Hypoxic burden and cumulative time with peripheral oxygen saturation below 90% remained independently associated with severe disease, with odds ratios of 1.35 (95%CI: 1.05-1.75; p = 0.021) and 2.46 (95%CI: 1.03-5.90; p = 0.043) respectively, whereas desaturation frequency was not significant after adjustment (odds ratio: 1.90; 95%CI: 0.97-3.73; p = 0.061). The model including cumulative time with peripheral oxygen saturation below 90% yielded an area under the curve of 0.86 (95%CI: 0.728-0.996), while the models including hypoxic burden and desaturation frequency yielded values regarding the area under the receiver operating characteristic (ROC) curve of 0.84 (95%CI: 0.698-0.989) and 0.78 (95%CI: 0.618-0.954) respectively. These findings suggest good discriminative performance of metrics reflecting cumulative nocturnal hypoxic exposure; however, formal comparisons between the ROC curves were not performed. Metrics reflecting cumulative exposure to nocturnal hypoxia demonstrated promising performance in distinguishing between moderate and severe disease, and they may contribute to risk stratification in obstructive sleep apnea.

Related

  1. Assessment of Nurses' Performance Regrading Caring of Patients with Acute Exacerbation of Chronic Obstructive Pulmonary Disease
    Asmaa H. Kandil, Ola A. Ahmed, Yosreah M. Mohamed +1
    Egyptian Journal of Health CarePeer-reviewedCC BYFull textGeneral medicineDOAJ
  2. Excessive Daytime Sleepiness and Obstructive Sleep Apnea Among Medical Students in Jordan and their Association with Academic Performance.
    Abdulrhman H M Muhaisen, Faris Al-Rabba, Mohammad Aleidi +6
    Saudi journal of medicine & medical sciencesPeer-reviewedCC BY-NC-SAFull textPhysiologyEurope PMCPMC
  3. Five years of Discover Oncology: reflecting on a rapidly evolving field
    Eleonora Candi
    Discover OncologyPeer-reviewedCC BYFull textObstetrics, gynaecology & paediatricsDOAJ
  4. TikTok Videos on Quadriceps Tendon Autografts for Anterior Cruciate Ligament Reconstruction Demonstrate Limited Information Quality
    Luis Vincent Bürck, Stephan Oehme, Danko Dan Milinkovic +3
    Medical sciences (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  5. Trochlear Morphological Parameters Based on Measurements at the Trochlear Groove Entry Plane Demonstrate Excellent Predictive Efficacy for Identifying the High‐Grade J‐Sign
    Jianzhong Sun, Yang Liu, Daofeng Wang +5
    Orthopaedic surgeryPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMC
BibTeX
@article{souza2026metrics,
  title = {{Metrics Reflecting Cumulative Exposure to Nocturnal Hypoxia Demonstrate Promising Performance in Distinguishing between Moderate and Severe Obstructive Sleep Apnea.}},
  author = {Shirley Nogueira de Souza and Jose Carlos Nóbrega Júnior and Roberta Torres and Thayse Neves Santos Silva and Gilvandro da Rocha Pessoa and Liliane Patrícia de Souza Mendes and Daniella Brandão and Shirley Campos and Armèle Dornelas de Andrade},
  journal = {Sleep science (Sao Paulo, Brazil)},
  year = {2026},
  month = sep,
  doi = {10.1055/s-0046-1829645},
  url = {https://europepmc.org/article/MED/43065340},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Metrics Reflecting Cumulative Exposure to Nocturnal Hypoxia Demonstrate Promising Performance in Distinguishing between Moderate and Severe Obstructive Sleep Apnea.
AU  - Shirley Nogueira de Souza
AU  - Jose Carlos Nóbrega Júnior
AU  - Roberta Torres
AU  - Thayse Neves Santos Silva
AU  - Gilvandro da Rocha Pessoa
AU  - Liliane Patrícia de Souza Mendes
AU  - Daniella Brandão
AU  - Shirley Campos
AU  - Armèle Dornelas de Andrade
PY  - 2026
DA  - 2026/09/01
JO  - Sleep science (Sao Paulo, Brazil)
DO  - 10.1055/s-0046-1829645
UR  - https://europepmc.org/article/MED/43065340
AB  - The apnea-hypopnea index is traditionally used to classify the severity of obstructive sleep apnea; however, it does not fully capture the cumulative physiological impact of nocturnal hypoxia. Metrics that quantify integrated hypoxic exposure may provide a more accurate characterization of disease severity. The current study compared the independent association and discriminative performance of hypoxic burden, cumulative time with peripheral oxygen saturation below 90%, and oxygen desaturation frequency in distinguishing between moderate and severe obstructive sleep apnea. In total, 30 patients with moderate or severe disease were evaluated using actigraphy combined with continuous nocturnal oximetry. Separate logistic regression models adjusted for body mass index were developed. Hypoxic burden and cumulative time with peripheral oxygen saturation below 90% remained independently associated with severe disease, with odds ratios of 1.35 (95%CI: 1.05-1.75; p = 0.021) and 2.46 (95%CI: 1.03-5.90; p = 0.043) respectively, whereas desaturation frequency was not significant after adjustment (odds ratio: 1.90; 95%CI: 0.97-3.73; p = 0.061). The model including cumulative time with peripheral oxygen saturation below 90% yielded an area under the curve of 0.86 (95%CI: 0.728-0.996), while the models including hypoxic burden and desaturation frequency yielded values regarding the area under the receiver operating characteristic (ROC) curve of 0.84 (95%CI: 0.698-0.989) and 0.78 (95%CI: 0.618-0.954) respectively. These findings suggest good discriminative performance of metrics reflecting cumulative nocturnal hypoxic exposure; however, formal comparisons between the ROC curves were not performed. Metrics reflecting cumulative exposure to nocturnal hypoxia demonstrated promising performance in distinguishing between moderate and severe disease, and they may contribute to risk stratification in obstructive sleep apnea.
SN  - 1984-0659
SN  - 1984-0063
ER  -