Radiographic view strongly influences detection of humeral component migration after stemless shoulder arthroplasty
4 affiliations
- 1Shoulder and Elbow Surgery Unit, ELSAN – Clinique de l’Orangerie, Strasbourg, France; Corresponding author: Maxime Antoni, MD, Shoulder and Elbow Surgery Unit, ELSAN – Clinique de l’Orangerie, 29 Allée de la Robertsau, Strasbourg 67000, France.
- 2Department of Orthopedic Surgery, CHU de Besançon, Besançon, France
- 3Shoulder Surgery Unit, Clinique Maussins Nollet – RAMSAY Santé, Paris, France
- 4Department of Orthopedic Surgery, Hôpital Saint Antoine - APHP, Paris, France
Abstract
Hypothesis and/or Background: Stemless humeral implants rely exclusively on metaphyseal fixation, making post-operative detection of humeral component migration important after stemless reverse shoulder arthroplasty. However, migration assessment on standard radiographs may be influenced by humeral rotation, particularly in the absence of a stem serving as a longitudinal radiographic landmark. The primary objective was to compare the sensitivity of 3 radiographic views, true anteroposterior in neutral rotation (RN), external rotation (RE), and internal rotation (RI), for detecting humeral component migration after stemless shoulder arthroplasty. Secondary objectives were to assess specificity, observer reliability, the influence of experience, and the minimal reliably detected displacement. Methods: An experimental radiographic study was performed using synthetic humeri implanted with a stemless humeral component. Controlled varus migration was sequentially created at the calcar level to predefined depths of 1, 3, 5, 7, and 10 mm. For each displacement condition, fluoroscopic images were obtained using RN, RE, and RI views. Ninety images were anonymized and presented in fully randomized order to 6 blinded observers, including 3 junior and 3 senior shoulder surgeons. Observers performed a binary assessment of migration presence compared with reference images. The evaluation was repeated after 1 month, resulting in 1,080 individual assessments. Sensitivity, specificity, interobserver and intraobserver reliability, and subgroup analyses according to observer experience were performed. Results: Overall sensitivity differed significantly according to radiographic view. RN demonstrated the highest sensitivity (90.7%), followed by RE (54.0%) and RI (29.0%) ( P < .001). Specificity was high across all views: 98.3% for RN, 98.3% for RI, and 96.7% for RE. Sensitivity increased with displacement magnitude, but reliable detection was mainly achieved for displacements greater than approximately 5 mm. Interobserver reliability was highest for RN (κ = 0.69; intraclass correlation coefficient [ICC] = 0.70), compared with RE (κ = 0.55; ICC = 0.56) and RI (κ = 0.57; ICC = 0.58). Intraobserver reliability was high, with mean weighted kappa and ICC values of 0.80. Senior observers showed higher overall sensitivity than junior observers (61.6% vs. 54.2%), although view ranking remained unchanged. Discussion and/or Conclusion: Radiographic detection of humeral component migration after stemless shoulder arthroplasty is highly dependent on projection and has limited reliability for small displacements. A standardized true anteroposterior view in RN is essential for accurate post-operative assessment, whereas rotational views markedly reduce sensitivity and may contribute to underdiagnosis or overdiagnosis.
Related
- Image-based robotic-assisted patellofemoral arthroplasty for isolated patellofemoral osteoarthritis: Short-term survivorship, clinical and radiographic outcomes
- Comparison of Fluoroscopy Use Between Two Radiographic Overlay Techniques for Limb Length and Femoral Offset Assessment During Direct Anterior Approach Total Hip Arthroplasty
- Agreement and Systematic Differences Between Intraoperative ROSA Hip-Knee-Ankle Measurements and Standing Radiographic Alignment After Robotic-Assisted Total Knee Arthroplasty: A Retrospective Agreement Study
- Tibial Component Malalignment in Total Ankle Arthroplasty
- Surgical approach and insert constraint are associated with small differences in patellar tilt after robotic‐assisted total knee arthroplasty: A retrospective comparative radiographic study
BibTeX
@article{maximeantoni2026radiographic,
title = {{Radiographic view strongly influences detection of humeral component migration after stemless shoulder arthroplasty}},
author = {Maxime Antoni, MD and Laurent Obert, MD, PhD and Alexandre Quemener, MD and Audrey Manceron, MD and Eloïse Duprot, MD and Claire Bastard, MD, PhD and Geoffroy Nourissat, MD, PhD},
journal = {JSES International},
year = {2026},
month = sep,
doi = {10.1016/j.jseint.2026.101793},
url = {https://doi.org/10.1016/j.jseint.2026.101793},
note = {CC BY-NC-ND 4.0},
}
RIS
TY - JOUR
TI - Radiographic view strongly influences detection of humeral component migration after stemless shoulder arthroplasty
AU - Maxime Antoni, MD
AU - Laurent Obert, MD, PhD
AU - Alexandre Quemener, MD
AU - Audrey Manceron, MD
AU - Eloïse Duprot, MD
AU - Claire Bastard, MD, PhD
AU - Geoffroy Nourissat, MD, PhD
PY - 2026
DA - 2026/09/11
JO - JSES International
DO - 10.1016/j.jseint.2026.101793
UR - https://doi.org/10.1016/j.jseint.2026.101793
AB - Hypothesis and/or Background: Stemless humeral implants rely exclusively on metaphyseal fixation, making post-operative detection of humeral component migration important after stemless reverse shoulder arthroplasty. However, migration assessment on standard radiographs may be influenced by humeral rotation, particularly in the absence of a stem serving as a longitudinal radiographic landmark. The primary objective was to compare the sensitivity of 3 radiographic views, true anteroposterior in neutral rotation (RN), external rotation (RE), and internal rotation (RI), for detecting humeral component migration after stemless shoulder arthroplasty. Secondary objectives were to assess specificity, observer reliability, the influence of experience, and the minimal reliably detected displacement. Methods: An experimental radiographic study was performed using synthetic humeri implanted with a stemless humeral component. Controlled varus migration was sequentially created at the calcar level to predefined depths of 1, 3, 5, 7, and 10 mm. For each displacement condition, fluoroscopic images were obtained using RN, RE, and RI views. Ninety images were anonymized and presented in fully randomized order to 6 blinded observers, including 3 junior and 3 senior shoulder surgeons. Observers performed a binary assessment of migration presence compared with reference images. The evaluation was repeated after 1 month, resulting in 1,080 individual assessments. Sensitivity, specificity, interobserver and intraobserver reliability, and subgroup analyses according to observer experience were performed. Results: Overall sensitivity differed significantly according to radiographic view. RN demonstrated the highest sensitivity (90.7%), followed by RE (54.0%) and RI (29.0%) ( P < .001). Specificity was high across all views: 98.3% for RN, 98.3% for RI, and 96.7% for RE. Sensitivity increased with displacement magnitude, but reliable detection was mainly achieved for displacements greater than approximately 5 mm. Interobserver reliability was highest for RN (κ = 0.69; intraclass correlation coefficient [ICC] = 0.70), compared with RE (κ = 0.55; ICC = 0.56) and RI (κ = 0.57; ICC = 0.58). Intraobserver reliability was high, with mean weighted kappa and ICC values of 0.80. Senior observers showed higher overall sensitivity than junior observers (61.6% vs. 54.2%), although view ranking remained unchanged. Discussion and/or Conclusion: Radiographic detection of humeral component migration after stemless shoulder arthroplasty is highly dependent on projection and has limited reliability for small displacements. A standardized true anteroposterior view in RN is essential for accurate post-operative assessment, whereas rotational views markedly reduce sensitivity and may contribute to underdiagnosis or overdiagnosis.
SN - 2666-6383
ER -