Skip to content
DraconiticResearch
Search Sources API
203,948 studies31 sourcesUpdated 41 min ago
Peer-reviewedCC BYJournal of clinical laboratory analysis

Rapid Detection of Klebsiella pneumoniae in Infants With Severe Infection Disease by Instant Nanofluorescent Microspheres-Immunochromatography Combined With Recombinase Polymerase Isothermal Amplification Technology.

4 affiliations
  1. 1School of Medical Technology, Xuzhou Medical University, Xuzhou, China.
  2. 2School of Chemical Engineering and Technology, China University of Mining and Technology, Xuzhou, China.
  3. 3Department of Clinical Laboratory, Xuzhou First People's Hospital, Xuzhou, China.
  4. 4School of Medical Imaging, Xuzhou Medical University, Xuzhou, China.

Abstract

Background

Klebsiella pneumoniae (KP) is an important and virulent pathogen causing acute respiratory infections in infants. Currently, traditional methods for detecting Klebsiella pneumoniae in babies are labour-intensive and time-consuming, and their accuracy and sensitivity require improvement. Recombinant enzyme polymerase amplification technology (RPA) has the advantages of good specificity, high sensitivity, and isothermal amplification. It can be combined with fluorescence immunochromatography test strip (FICTS) based on nanofluorescent microspheres (nFM) to achieve rapid, low-cost, high sensitivity, and specific detection of Klebsiella pneumoniae in infants.Methods

mdh was selected as a genus-specific gene from Klebsiella pneumoniae, and recombinant polymerase isothermal amplification-nanofluorescence microsphere immunochromatography (RPA-FICTS) was established by using standard strains. The sensitivity and specificity of this detection technology can be improved by the magnetic bead purification step of RPA nucleic acid amplification products. Subsequently, rapid quantitative detection of K. pneumoniae in infant samples was performed using fluorescent immunochromatographic test strips. A total of 19 clinical samples of Klebsiella pneumoniae (KP) and 7 clinical samples of non-Klebsiella pneumoniae (nKP) were detected by the new detection technology platform established in this paper, and the specificity and sensitivity of RPA-FICTS were verified by agarose gel electrophoresis.Results

Under the optimal detection conditions, the maximum detection limits of RPA-GE (agarose gel electrophoresis) and RPA-FICTS are 9.03 × 10⁻³ and 9.03 × 10⁻⁸ ng/μL. RPA-FICTS can quickly detect Klebsiella pneumoniae and specifically distinguish between Klebsiella pneumoniae and non-Klebsiella pneumoniae. Compared with traditional detection methods, this method has a shorter detection time (55 min), strong specificity, high sensitivity, and simple operation, providing a new method for rapid detection of human Klebsiella pneumoniae.

Related

  1. Synergistic Integration of Recombinase Polymerase Amplification and CRISPR–Cas12a Enables High‐Sensitivity Detection of Mycoplasma bovis
    Diba Yaghoubi, Viju V. Pillai
    MicrobiologyOpenPeer-reviewedCC BYFull textEurope PMC
  2. A Review of Recombinase-Aided Amplification (RAA) in Veterinary Medicine
    Shaomei Li, Jieqi Gao, Yongqiang Miao +9
    MicroorganismsPeer-reviewedCC BYFull textEurope PMC
  3. Development of a Rapid, Sensitive, and Visual Recombinase-Aided Amplification Combined with Pyrococcus furiosus Argonaute (RAA-PfAgo) Assay for Sex Identification in Swinhoe’s Pheasant (Lophura swinhoii)
    Tongtong Zhan, Fanrong Liu, Huan Zhang +10
    Current issues in molecular biologyPeer-reviewedCC BYFull textEurope PMC
  4. Rapid recombinase polymerase amplification-based detection of the bar gene for environmental monitoring of genetically modified soybean and rice.
    Areum Jeong, Sung-Dug Oh, Sara Noh +4
    GM crops & foodPeer-reviewedCC BY-NCFull textPlant biologyEurope PMC
  5. Development of a multiplex detection system for toxic Amanita species based on isothermal recombinase polymerase amplification and CRISPR/Cas12b technology
    Hao Li, Xinyu Ying, Zhidan Luo +2
    Frontiers in Molecular BiosciencesPeer-reviewedCC BY 4.0Full textMolecular biology & gene regulationPMCEurope PMC
BibTeX
@article{liu2026rapid,
  title = {{Rapid Detection of Klebsiella pneumoniae in Infants With Severe Infection Disease by Instant Nanofluorescent Microspheres-Immunochromatography Combined With Recombinase Polymerase Isothermal Amplification Technology.}},
  author = {Yiping Liu and Yi Lu and Xin Wang and Hanzhong Yu and Yumeng Lu and Minghui Chen and Feifan Zhu and Xing Lv and Li Wang and Ying Chen},
  journal = {Journal of clinical laboratory analysis},
  year = {2026},
  month = oct,
  doi = {10.1002/jcla.70348},
  url = {https://europepmc.org/article/MED/42850998},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Rapid Detection of Klebsiella pneumoniae in Infants With Severe Infection Disease by Instant Nanofluorescent Microspheres-Immunochromatography Combined With Recombinase Polymerase Isothermal Amplification Technology.
AU  - Yiping Liu
AU  - Yi Lu
AU  - Xin Wang
AU  - Hanzhong Yu
AU  - Yumeng Lu
AU  - Minghui Chen
AU  - Feifan Zhu
AU  - Xing Lv
AU  - Li Wang
AU  - Ying Chen
PY  - 2026
DA  - 2026/10/08
JO  - Journal of clinical laboratory analysis
DO  - 10.1002/jcla.70348
UR  - https://europepmc.org/article/MED/42850998
AB  - Background  Klebsiella pneumoniae (KP) is an important and virulent pathogen causing acute respiratory infections in infants. Currently, traditional methods for detecting Klebsiella pneumoniae in babies are labour-intensive and time-consuming, and their accuracy and sensitivity require improvement. Recombinant enzyme polymerase amplification technology (RPA) has the advantages of good specificity, high sensitivity, and isothermal amplification. It can be combined with fluorescence immunochromatography test strip (FICTS) based on nanofluorescent microspheres (nFM) to achieve rapid, low-cost, high sensitivity, and specific detection of Klebsiella pneumoniae in infants.Methods  mdh was selected as a genus-specific gene from Klebsiella pneumoniae, and recombinant polymerase isothermal amplification-nanofluorescence microsphere immunochromatography (RPA-FICTS) was established by using standard strains. The sensitivity and specificity of this detection technology can be improved by the magnetic bead purification step of RPA nucleic acid amplification products. Subsequently, rapid quantitative detection of K. pneumoniae in infant samples was performed using fluorescent immunochromatographic test strips. A total of 19 clinical samples of Klebsiella pneumoniae (KP) and 7 clinical samples of non-Klebsiella pneumoniae (nKP) were detected by the new detection technology platform established in this paper, and the specificity and sensitivity of RPA-FICTS were verified by agarose gel electrophoresis.Results  Under the optimal detection conditions, the maximum detection limits of RPA-GE (agarose gel electrophoresis) and RPA-FICTS are 9.03 × 10⁻³ and 9.03 × 10⁻⁸ ng/μL. RPA-FICTS can quickly detect Klebsiella pneumoniae and specifically distinguish between Klebsiella pneumoniae and non-Klebsiella pneumoniae. Compared with traditional detection methods, this method has a shorter detection time (55 min), strong specificity, high sensitivity, and simple operation, providing a new method for rapid detection of human Klebsiella pneumoniae.
SN  - 0887-8013
SN  - 1098-2825
ER  -