Development and Application of a Magnetoelectric Coupling Measurement System for Strain-Mediated Effects

Abstract

This paper reports about development of a dynamic lock-in based magnetoelectric (ME) coupling measurement system and its application to investigate strain-mediated coupling in 0.65Pb(Mg1/3Nb2/3)O3-0.35PbTiO3/NiFe2O4 (PMN-PT/NFO) and CoFe2O4/BaTiO3 (CFO/BTO) composites. The PMN-PT/NFO composite exhibits a significantly enhanced ME coefficient (αME ≈ 1.85~mV\,mm−1\,Oe−1) compared to CFO/BTO (≈ 0.147~mV\,mm−1\,Oe−1). The antisymmetric field dependence and 180∘ phase reversal confirm the strain-driven origin of coupling in both the samples. The superior response of PMN-PT/NFO arises from the combined effect of high piezoelectric strength in PMN-PT and low magnetic anisotropy of NFO, whereas the high magnetic anisotropy of CFO and weaker piezoelectricity of BTO limit the ME output. These results highlight the decisive role of magnetic softness and piezoelectric strength in optimizing strain-mediated ME coupling.

Related

  1. Deleterious effect of photon-phonon coupling on microcavities in their application as quantum sources
    Y. Sacha C. L. S., G. C. Rickli, J. Dipold +4
    arXivPreprintCC BY-NC-ND 4.0Full textOptics & photonicsQuantum physics & quantum informationarXiv
  2. Measurement of strain by tracking of nano-droplets, application for the study of slip bands in steel Eurofer97
    A Ollivier, Döme Tanguy
    HALPreprintCC BY 4.0Full textGeneral physicsHAL
  3. The Metrology Atlas: describing recorded physiological data as a measurement system, with VitalDB as a first application
    Andrew J. Goodwin
    arXivPreprintCC BY 4.0Full textBiological & medical physicsarXiv
  4. Exchange-mediated directional coupling of short-wavelength spin waves
    Zhen Zhu, Roman Verba, Philipp Pirro +2
    arXivPreprintCC BY 4.0Full textApplied physics & instrumentationarXiv
  5. Gradient-Based Curvature-Only Time-Derivative Coupling for Surface Hopping and Coherent Switching with Decay of Mixing: Application to SO2 and Molecular Tully Models.
    Feven-Alemu Korsaye, Leticia González
    Journal of chemical theory and computationPeer-reviewedCC BYFull textAtomic, molecular & optical physicsEurope PMC
BibTeX
@misc{mohanta2026development,
  title = {{Development and Application of a Magnetoelectric Coupling Measurement System for Strain-Mediated Effects}},
  author = {Samanway Mohanta and Poonacha C. T and Hemant Singh and Gunjan Verma and A. Ahlawat and S. C. Das and G. Sinha and V. G. Sathe and D. K. Shukla},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2610.04599},
  eprint = {2610.04599},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.04599},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - Development and Application of a Magnetoelectric Coupling Measurement System for Strain-Mediated Effects
AU  - Samanway Mohanta
AU  - Poonacha C. T
AU  - Hemant Singh
AU  - Gunjan Verma
AU  - A. Ahlawat
AU  - S. C. Das
AU  - G. Sinha
AU  - V. G. Sathe
AU  - D. K. Shukla
PY  - 2026
DA  - 2026/10/03
PB  - arXiv
DO  - 10.48550/arxiv.2610.04599
UR  - https://arxiv.org/abs/2610.04599
AB  - This paper reports about development of a dynamic lock-in based magnetoelectric (ME) coupling measurement system and its application to investigate strain-mediated coupling in 0.65Pb(Mg_1/3Nb_2/3)O_3-0.35PbTiO_3/NiFe_2O_4 (PMN-PT/NFO) and CoFe_2O_4/BaTiO_3 (CFO/BTO) composites. The PMN-PT/NFO composite exhibits a significantly enhanced ME coefficient (α_ME ≈ 1.85~mV\,mm^−1\,Oe^−1) compared to CFO/BTO (≈ 0.147~mV\,mm^−1\,Oe^−1). The antisymmetric field dependence and 180^∘ phase reversal confirm the strain-driven origin of coupling in both the samples. The superior response of PMN-PT/NFO arises from the combined effect of high piezoelectric strength in PMN-PT and low magnetic anisotropy of NFO, whereas the high magnetic anisotropy of CFO and weaker piezoelectricity of BTO limit the ME output. These results highlight the decisive role of magnetic softness and piezoelectric strength in optimizing strain-mediated ME coupling.
ER  -