Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 15 min ago
Peer-reviewedCC BYJournal of experimental orthopaedics

MAKO robotic‐assisted versus computed tomography‐based navigated and conventional total hip arthroplasty in patients with developmental dysplasia of the hip: A systematic review and meta‐analysis

  1. 1Student Research Committee, School of Medicine Shahid Beheshti University of Medical Sciences Tehran Iran.
  2. 2School of Medicine Tehran University of Medical Sciences Tehran Iran.

Abstract

Purpose

To compare implant positioning and clinical outcomes of MAKO robotic arm-assisted total hip arthroplasty (R-THA) with conventional THA (C-THA) and computed tomography (CT)-based navigated THA (N-THA) in developmental dysplasia of the hip (DDH).Methods

This systematic review and meta-analysis followed Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) 2020 and the Cochrane Handbook. PubMed, Scopus, Web of Science and Embase were searched up to 30 October 2025. Eligible studies compared MAKO R-THA with C-THA and/or N-THA in DDH patients. Risk of bias was assessed using the Risk of Bias in Non-Randomized Studies of Interventions (ROBINS-I) tool. Meta-analysis was performed with STATA 18.0 using random-effects models. Pooled mean differences (MDs) and risk ratios (RRs) were calculated. Heterogeneity was assessed using the I ² statistic, and the certainty of evidence was evaluated using the Grading of Recommendations, Assessment, Development and Evaluations (GRADE) framework.Results

Nine observational studies involving 1130 hips (562 MAKO R-THA, 442 C-THA and 126 N-THA) were included. Compared with C-THA, MAKO R-THA significantly improved horizontal center of rotation (COR) restoration (MD = -1.01 mm, 95% confidence interval [CI] [-1.49 to -0.54]), while no significant differences were observed in operative time, intraoperative blood loss, vertical COR and overall complication rate. Compared with N-THA, MAKO R-THA achieved significantly smaller deviations from planned acetabular inclination (MD = -1.47°, 95% CI [-2.11 to -0.83]) and anteversion (MD = -1.60°, 95% CI [-2.21 to -0.99]).Conclusions

In patients with DDH, MAKO R-THA demonstrated small, statistically significant improvements in specific radiographic parameters (lower horizontal COR deviation vs. C-THA and smaller inclination and anteversion deviations vs. CT-based N-THA). However, these modest radiographic differences have not been shown to translate into superior clinical function, patient-reported outcomes or lower complication rates. Long-term studies are needed to determine whether these technical precision gains affect implant survivorship.Level of evidence

Level III.

Related

  1. Level-Specific Analysis of Intraoperative Computed Tomography–Navigated vs Fluoroscopy-Assisted Lumbar Pedicle Screw Placement Accuracy: A Retrospective Cohort Study
    Mario Giordano, Federico Iaccarino, Amir Kaywan Aftahy +3
    International Journal of Spine SurgeryPeer-reviewedLicence not statedFull textSurgery & anaesthesiaPMC
  2. Return to sports after robotic-assisted versus conventional total and unicompartmental knee arthroplasty: a systematic review of the current evidence.
    Gregorio Alberto, Yazan Abu Salem, Elena Bardi +2
    BMC musculoskeletal disordersPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMCPMC
  3. Twenty-Year Wear Progression and Long-Term Outcomes of Conventional Polyethylene Liners After Cementless Total Hip Arthroplasty
    Yasutaka Watanabe, Toru Moro, Hisatoshi Ishikura +3
    Arthroplasty todayPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMC
  4. The Sacro-Femoral-Pubic Angle May Estimate Pelvic Tilt in Patients with Severe Developmental Dysplasia of the Hip and Leg Length Discrepancy Undergoing Total Hip Arthroplasty
    Özgür Avci, Alpaslan Öztürk, Yavuz Akalın +3
    Clinics in orthopedic surgeryPeer-reviewedCC BY-NCFull textSurgery & anaesthesiaEurope PMC
  5. Long-term outcomes of bioabsorbable polylactide scaffold-based versus conventional arthroplasty for trapeziometacarpal osteoarthritis.
    Antek Nicklas, Feras Taqatqeh, Adrian Dragu +1
    GMS Interdisciplinary plastic and reconstructive surgery DGPWPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMC
BibTeX
@article{amiri2026mako,
  title = {{MAKO robotic‐assisted versus computed tomography‐based navigated and conventional total hip arthroplasty in patients with developmental dysplasia of the hip: A systematic review and meta‐analysis}},
  author = {Amirhossein Amiri and Ariyan Ayati Firoozabadi and Sadra Mohebbi},
  journal = {Journal of experimental orthopaedics},
  year = {2026},
  month = oct,
  doi = {10.1002/jeo2.70999},
  url = {https://europepmc.org/article/PMC/PMC13794306},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - MAKO robotic‐assisted versus computed tomography‐based navigated and conventional total hip arthroplasty in patients with developmental dysplasia of the hip: A systematic review and meta‐analysis
AU  - Amirhossein Amiri
AU  - Ariyan Ayati Firoozabadi
AU  - Sadra Mohebbi
PY  - 2026
DA  - 2026/10/01
JO  - Journal of experimental orthopaedics
DO  - 10.1002/jeo2.70999
UR  - https://europepmc.org/article/PMC/PMC13794306
AB  - Purpose  To compare implant positioning and clinical outcomes of MAKO robotic arm-assisted total hip arthroplasty (R-THA) with conventional THA (C-THA) and computed tomography (CT)-based navigated THA (N-THA) in developmental dysplasia of the hip (DDH).Methods  This systematic review and meta-analysis followed Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) 2020 and the Cochrane Handbook. PubMed, Scopus, Web of Science and Embase were searched up to 30 October 2025. Eligible studies compared MAKO R-THA with C-THA and/or N-THA in DDH patients. Risk of bias was assessed using the Risk of Bias in Non-Randomized Studies of Interventions (ROBINS-I) tool. Meta-analysis was performed with STATA 18.0 using random-effects models. Pooled mean differences (MDs) and risk ratios (RRs) were calculated. Heterogeneity was assessed using the I ² statistic, and the certainty of evidence was evaluated using the Grading of Recommendations, Assessment, Development and Evaluations (GRADE) framework.Results  Nine observational studies involving 1130 hips (562 MAKO R-THA, 442 C-THA and 126 N-THA) were included. Compared with C-THA, MAKO R-THA significantly improved horizontal center of rotation (COR) restoration (MD = -1.01 mm, 95% confidence interval [CI] [-1.49 to -0.54]), while no significant differences were observed in operative time, intraoperative blood loss, vertical COR and overall complication rate. Compared with N-THA, MAKO R-THA achieved significantly smaller deviations from planned acetabular inclination (MD = -1.47°, 95% CI [-2.11 to -0.83]) and anteversion (MD = -1.60°, 95% CI [-2.21 to -0.99]).Conclusions  In patients with DDH, MAKO R-THA demonstrated small, statistically significant improvements in specific radiographic parameters (lower horizontal COR deviation vs. C-THA and smaller inclination and anteversion deviations vs. CT-based N-THA). However, these modest radiographic differences have not been shown to translate into superior clinical function, patient-reported outcomes or lower complication rates. Long-term studies are needed to determine whether these technical precision gains affect implant survivorship.Level of evidence  Level III.
SN  - 2197-1153
ER  -