Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 15 min ago
PreprintCC BY 4.0HAL

High order harmonic Optical Reconstruction by delayed time-depeNdent Ellipticity perturbaTion: HORNET

Abstract

We present and demonstrate an all-optical in situ method for temporal characterisation of high-order harmonics generated in gas with a linearly polarised intense infrared (IR) laser. By using a delayed cross-polarised replica of the IR pulse with a lower amplitude, we introduce a weak and time-dependent ellipticity in the IR driving field. Since the XUV emission is very sensitive to the ellipticity of the driving field, it is perturbed precisely at the times when ellipticity is significant. The detected emission is then reduced only if the unperturbed XUV emission is substantial at these times. Perturbed XUV spectra are recorded for several delays and exhibit changes both in amplitude and in their spectral content. An iterative ptychographic algorithm is used to retrieve the electric field of individual harmonics in a very robust way. Experimental measurements are in good agreement with simulations. The reconstructed temporal profiles show a steady evolution of the XUV pulse duration and chirp with the harmonic order. The highest harmonics exhibit a positive chirp and are emitted in the rising front of the IR driving pulse, while the lowest ones exhibit a negative chirp and are emitted throughout the entire pulse.

Related

  1. All-optical reconstruction of valley polarization through helicity-resolved high-harmonic generation
    Xiaoyu Bu, Yan Meng, Xiaohui Zhao +2
    arXivPreprintarXiv licenceFull textAtomic, molecular & optical physicsOptics & photonicsarXiv
  2. Terahertz Control of Optical Second-Harmonic Generation in Displacive Ferroelectrics: Electronic Bloch-State Reconstruction
    Hong-Kui Liu, Zi-Chen Qin, Jun-Song Wu +1
    arXivPreprintarXiv licenceFull textCondensed matterarXiv
  3. Simultaneous measurement of magneto-optical rotation and ellipticity using dual-pointers weak measurement
    Yifan Wang, Shushu Shi, Lan Luo +4
    Optics ExpressPeer-reviewedPublisher termsOptics & photonicsCrossref
  4. Tailoring optical Schrödinger cat states via orientation-dependent high-harmonic generation in H2+
    Ziyang Gan, Ahai Chen, Yuhai Jiang
    arXivPreprintarXiv licenceFull textAtomic, molecular & optical physicsComputational physicsarXiv
  5. Perturbation-Based Reconstruction of Depth-Resolved OCT Attenuation without Requiring a Fully Decayed Signal Tail
    Jinglun Yu, Yaning Wang, Shuwen Wei +1
    arXivPreprintarXiv licenceFull textOptics & photonicsarXiv
BibTeX
@misc{perez2026high,
  title = {{High order harmonic Optical Reconstruction by delayed time-depeNdent Ellipticity perturbaTion: HORNET}},
  author = {Lucas Perez and Corentin Picot and Stefan Skupin and Fabrice Catoire and Eric Constant},
  howpublished = {HAL},
  year = {2026},
  month = jun,
  eprint = {2606.26908},
  archivePrefix = {arXiv},
  url = {https://hal.science/hal-05766710v1},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - High order harmonic Optical Reconstruction by delayed time-depeNdent Ellipticity perturbaTion: HORNET
AU  - Lucas Perez
AU  - Corentin Picot
AU  - Stefan Skupin
AU  - Fabrice Catoire
AU  - Eric Constant
PY  - 2026
DA  - 2026/06/26
PB  - HAL
UR  - https://hal.science/hal-05766710v1
AB  - We present and demonstrate an all-optical in situ method for temporal characterisation of high-order harmonics generated in gas with a linearly polarised intense infrared (IR) laser. By using a delayed cross-polarised replica of the IR pulse with a lower amplitude, we introduce a weak and time-dependent ellipticity in the IR driving field. Since the XUV emission is very sensitive to the ellipticity of the driving field, it is perturbed precisely at the times when ellipticity is significant. The detected emission is then reduced only if the unperturbed XUV emission is substantial at these times. Perturbed XUV spectra are recorded for several delays and exhibit changes both in amplitude and in their spectral content. An iterative ptychographic algorithm is used to retrieve the electric field of individual harmonics in a very robust way. Experimental measurements are in good agreement with simulations. The reconstructed temporal profiles show a steady evolution of the XUV pulse duration and chirp with the harmonic order. The highest harmonics exhibit a positive chirp and are emitted in the rising front of the IR driving pulse, while the lowest ones exhibit a negative chirp and are emitted throughout the entire pulse.
ER  -