Skip to content
DraconiticResearch
Search Sources API
203,948 studies31 sourcesUpdated 47 min ago
Peer-reviewedCC BY 4.0Therapeutic Innovation & Regulatory Science

BE-BOIN: A Dose Optimization Design Accommodating Backfill and Late-Onset Toxicity

4 affiliations
  1. 1Eli Lilly and Company, Indianapolis, IN USA
  2. 2Department of Biostatistics and Data Science, The University of Texas Health Science Center, Houston, TX USA
  3. 3Astellas Pharma Global Development Inc., Northbrook, IL USA
  4. 4Department of Biostatistics, The University of Texas MD Anderson Cancer Center, Houston, TX USA

Abstract

The US Food and Drug Administration (FDA) launched Project Optimus and issued guidance to reform dose-finding and selection trials, shifting the paradigm from identifying the maximum tolerated dose (MTD) to determining the optimal biological dose (OBD), which optimizes the risk and benefit of treatments. The FDA’s guidance emphasizes the importance of collecting sufficient toxicity and efficacy data across multiple doses and considering late-onset cumulative toxicity that often results in tolerability issues. To address these challenges, we propose the BE-BOIN (Backfill time-to-Event Bayesian Optimal INterval) design, which allows backfilling patients into safe and effective doses during dose escalation and accommodates late-onset toxicities. BE-BOIN enables the collection of additional safety and efficacy data to enhance the accuracy and reliability of OBD selection and supports real-time dose decisions for new patients. Our simulation studies show that BE-BOIN accurately identifies the MTD and OBD while significantly reducing trial duration.

Supplementary Information: The online version contains supplementary material available at https://doi.org/10.1007/s43441-026-00994-0.

Related

  1. A model-assisted design for phase I oncology drug combination trials incorporating backfill
    Connor Celum, Evan M. Bagley
    arXivPreprintarXiv licenceFull textStatisticsarXiv
  2. Transfer learning in bayesian optimization for aircraft design
    Ali Tfaily, Youssef Diouane, Nathalie Bartoli +1
    Structural and Multidisciplinary OptimizationPeer-reviewedCC BY-NC-SAFull textGeneral mathematicsGeneral physicsHAL
  3. Portfolio-Based Constrained Multi-Objective Bayesian Optimization for Materials Design
    Sushant Sinha, Christofer Hardcastle, Robert Robinson +4
    arXivPreprintarXiv licenceFull textStatisticsCondensed matterarXiv
  4. From Corridor Selection to Earthwork: A Multi-Stage Framework for Automated Road Design via Steiner Trees and Convex Optimization
    Paavai Manimaran Vanjeenathammal, John R. J. Thompson, Warren Hare +1
    arXivPreprintCC BY-NC-SA 4.0Full textOptimisation & controlarXiv
  5. First-Order Bilevel Optimization for Non-truthful Auction Design
    Shing-Hei Ho, April Niu, Ellen Vitercik +1
    arXivPreprintCC BY 4.0Full textOptimisation & controlarXiv
BibTeX
@article{chen2026beboin,
  title = {{BE-BOIN: A Dose Optimization Design Accommodating Backfill and Late-Onset Toxicity}},
  author = {Kai Chen and Yixuan Zhao and Kentaro Takeda and Ying Yuan},
  journal = {Therapeutic Innovation \& Regulatory Science},
  year = {2026},
  month = aug,
  doi = {10.1007/s43441-026-00994-0},
  url = {https://doi.org/10.1007/s43441-026-00994-0},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - BE-BOIN: A Dose Optimization Design Accommodating Backfill and Late-Onset Toxicity
AU  - Kai Chen
AU  - Yixuan Zhao
AU  - Kentaro Takeda
AU  - Ying Yuan
PY  - 2026
DA  - 2026/08/10
JO  - Therapeutic Innovation & Regulatory Science
DO  - 10.1007/s43441-026-00994-0
UR  - https://doi.org/10.1007/s43441-026-00994-0
AB  - The US Food and Drug Administration (FDA) launched Project Optimus and issued guidance to reform dose-finding and selection trials, shifting the paradigm from identifying the maximum tolerated dose (MTD) to determining the optimal biological dose (OBD), which optimizes the risk and benefit of treatments. The FDA’s guidance emphasizes the importance of collecting sufficient toxicity and efficacy data across multiple doses and considering late-onset cumulative toxicity that often results in tolerability issues. To address these challenges, we propose the BE-BOIN (Backfill time-to-Event Bayesian Optimal INterval) design, which allows backfilling patients into safe and effective doses during dose escalation and accommodates late-onset toxicities. BE-BOIN enables the collection of additional safety and efficacy data to enhance the accuracy and reliability of OBD selection and supports real-time dose decisions for new patients. Our simulation studies show that BE-BOIN accurately identifies the MTD and OBD while significantly reducing trial duration.  Supplementary Information: The online version contains supplementary material available at https://doi.org/10.1007/s43441-026-00994-0.
SN  - 2168-4790
SN  - 2168-4804
ER  -