Demonstration of a 10-metre-long discharge plasma source for plasma wakefield acceleration
Abstract
The AWAKE experiment at CERN uses high-energy proton bunches to drive plasma wakefields capable of accelerating electron bunches up to hundreds of GeV in a single plasma. Realising this potential requires a plasma source that can extend to tens of metres while maintaining high longitudinal uniformity and reproducibility. Towards this goal, we report on the first experimental characterisation and beam-based validation of a 10-metre-long pulsed-DC discharge plasma source (DPS) used as an alternative to the laser-ionised rubidium vapour plasma source (VPS). The DPS reliably delivered plasma densities in three noble gases (He, Ar, Xe) at electron densities between 1014 and 1015 cm−3. Proton bunch self-modulation was observed with all three gases, and the resulting modulation frequency was used as a beam-based diagnostic of the plasma density, showing good agreement with laboratory interferometry measurements. The event-to-event modulation frequency was demonstrated to be reproducible to within 0.63%, comparable to that of the VPS. These results establish the DPS as a valid alternative plasma source for beam-driven wakefield experiments, and support its further development towards longer plasma lengths. The present design is tailored to AWAKE requirements, but the underlying discharge concept provides a route to long, reproducible plasma sources with straightforward density control through discharge-beam timing for other beam-plasma experiments.
Related
- Beam-driven plasma wakefield acceleration
- Heavy ion driven plasma wakefield acceleration with drift-like phase-shift acceleration scheme
- Unveiling the beam-wake interactions in plasma wakefield acceleration
- High-Efficiency Wakefield Acceleration of Positrons via a Slit Plasma Channel
- Laser wakefield acceleration and x-ray emission in plasma produced by the electrical explosion of an aluminum wire
BibTeX
@misc{amoedo2026demonstration,
title = {{Demonstration of a 10-metre-long discharge plasma source for plasma wakefield acceleration}},
author = {C. Amoedo and N. Lopes and N. E. Torrado and F. Silva and P. Muggli and L. Verra and M. Turner and G. Zevi Della Porta and M. Bergamaschi and A. Clairembaud and J. Mezger and F. Pannell and N. Z. van Gils and E. Gschwendtner and A. Sublet and the AWAKE Collaboration},
howpublished = {arXiv},
year = {2026},
month = sep,
doi = {10.48550/arxiv.2609.08551},
eprint = {2609.08551},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2609.08551},
note = {CC BY 4.0},
}
RIS
TY - UNPB
TI - Demonstration of a 10-metre-long discharge plasma source for plasma wakefield acceleration
AU - C. Amoedo
AU - N. Lopes
AU - N. E. Torrado
AU - F. Silva
AU - P. Muggli
AU - L. Verra
AU - M. Turner
AU - G. Zevi Della Porta
AU - M. Bergamaschi
AU - A. Clairembaud
AU - J. Mezger
AU - F. Pannell
AU - N. Z. van Gils
AU - E. Gschwendtner
AU - A. Sublet
AU - the AWAKE Collaboration
PY - 2026
DA - 2026/09/08
PB - arXiv
DO - 10.48550/arxiv.2609.08551
UR - https://arxiv.org/abs/2609.08551
AB - The AWAKE experiment at CERN uses high-energy proton bunches to drive plasma wakefields capable of accelerating electron bunches up to hundreds of GeV in a single plasma. Realising this potential requires a plasma source that can extend to tens of metres while maintaining high longitudinal uniformity and reproducibility. Towards this goal, we report on the first experimental characterisation and beam-based validation of a 10-metre-long pulsed-DC discharge plasma source (DPS) used as an alternative to the laser-ionised rubidium vapour plasma source (VPS). The DPS reliably delivered plasma densities in three noble gases (He, Ar, Xe) at electron densities between 10^14 and 10^15 cm^−3. Proton bunch self-modulation was observed with all three gases, and the resulting modulation frequency was used as a beam-based diagnostic of the plasma density, showing good agreement with laboratory interferometry measurements. The event-to-event modulation frequency was demonstrated to be reproducible to within 0.63%, comparable to that of the VPS. These results establish the DPS as a valid alternative plasma source for beam-driven wakefield experiments, and support its further development towards longer plasma lengths. The present design is tailored to AWAKE requirements, but the underlying discharge concept provides a route to long, reproducible plasma sources with straightforward density control through discharge-beam timing for other beam-plasma experiments.
ER -