Skip to content
DraconiticResearch
Search Sources API
226,742 studies31 sourcesUpdated 44 min ago
Peer-reviewedCC BYTranslational Research in Anatomy

Ultrasonographic mapping of the median cubital vein: Tourniquet-Induced changes and demographic variation relevant to safe venipuncture

  1. 1St George's University School of Medicine, Grenada, Northumbria University Campus, Newcastle, United Kingdom
  2. 2St George's University School of Medicine, Grenada, Northumbria University Campus, Newcastle, United Kingdom; Department of Anatomy, St. George's University, West Indies, Grenada; Corresponding author. St George's University School of Medicine, Grenada; Northumbria University Campus, Newcastle, NE1 8ST, United Kingdom.

Abstract

Purpose: The median cubital vein (MCV) is frequently used for venipuncture, but anatomical variation and tourniquet application can alter its relationship to the brachial artery and median nerve. This study used ultrasonography to characterise these effects across sex and ethnicity. Methods: Sixty healthy adults (28 men, 32 women; aged 18–46 years) from South Asian, Middle Eastern and North African (MENA), Sub-Saharan African (SSA), and other backgrounds underwent ultrasonographic assessment (GE LOGIQ system, 12 MHz linear transducer) of MCV diameter and its distance from the brachial artery, median nerve, and skin surface, before and after tourniquet application. Results: Tourniquet application significantly increased MCV diameter and its distance from the brachial artery and median nerve (p < 0.05), with no significant change in skin depth. MCV diameter did not differ significantly by sex; however, after tourniquet application, males showed significantly greater distance from the brachial artery and median nerve than females (p < 0.05). MCV diameter differed significantly across ethnic groups after tourniquet application (one-way ANOVA, p = 0.037), with MENA participants having the largest and SSA participants the smallest mean diameter; no other parameter differed by ethnicity. Anatomical variants included MCV absence (8.3%), MCV coursing deep to the bicipital aponeurosis (3.6% of visualized veins), and the brachial artery or median nerve lying directly beneath the MCV (5.5%). Conclusion: Tourniquet application, sex, and ethnicity significantly influence MCV anatomy and its neurovascular relationships. Ultrasonography reliably detects clinically important variants that could compromise venipuncture safety, supporting its selective use before vascular access in high-risk patients.

Related

  1. TCF7L2 functionally relevant genetic variation with clinical implications in bipolar disorder with impaired glucose metabolism
    Alessandro Miola, Stacey J. Winham, De De Filippis +15
    Translational PsychiatryPeer-reviewedCC BY-NC-ND 4.0Psychiatry & mental healthCrossref
  2. Scalable context-dependent single-cell eQTL mapping reveals disease-relevant regulatory variation beyond static models
    Y. C. Liu, A. S. E. Cuomo, Y. Huang +15
    medRxivPreprintCC BYFull text1 citedHuman geneticsmedRxiv
  3. A Global Atlas of Immune Alleles Reveals Health-Relevant Variation Across Groups
    W. T. Harvey, A.-K. Emde, F. E. Kakembo +26
    medRxivPreprintCC BY-NCFull textHuman geneticsmedRxiv
  4. Suicide mortality in Kazakhstan from 2012 to 2024: temporal trends, demographic inequalities, and regional variation
    Alibek Kossumov, Tolkyn Zhakupova, Nazgul Imambayeva +9
    Frontiers in Public HealthPeer-reviewedCC BY 4.0Full textPsychiatry & mental healthCrossrefEurope PMCPMC
  5. Wide-awake local anaesthesia without routine tourniquet for cubital tunnel surgery: A systematic review and meta-analysis
    Gaurav Jha, Surya Malasani, William Elliott +2
    Journal of Hand and MicrosurgeryPeer-reviewedLicence not statedFull textSurgery & anaesthesiaPMC
BibTeX
@article{patker2026ultrasonographic,
  title = {{Ultrasonographic mapping of the median cubital vein: Tourniquet-Induced changes and demographic variation relevant to safe venipuncture}},
  author = {Shaan Patker and Saif Bunni and Fatima Elasha and Asra Qureshi and Manasvi Kankaria and Shanguan Zhao and Fouzan Ali and Sadia Javaid},
  journal = {Translational Research in Anatomy},
  year = {2026},
  month = nov,
  doi = {10.1016/j.tria.2026.100519},
  url = {https://doi.org/10.1016/j.tria.2026.100519},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Ultrasonographic mapping of the median cubital vein: Tourniquet-Induced changes and demographic variation relevant to safe venipuncture
AU  - Shaan Patker
AU  - Saif Bunni
AU  - Fatima Elasha
AU  - Asra Qureshi
AU  - Manasvi Kankaria
AU  - Shanguan Zhao
AU  - Fouzan Ali
AU  - Sadia Javaid
PY  - 2026
DA  - 2026/11/16
JO  - Translational Research in Anatomy
DO  - 10.1016/j.tria.2026.100519
UR  - https://doi.org/10.1016/j.tria.2026.100519
AB  - Purpose: The median cubital vein (MCV) is frequently used for venipuncture, but anatomical variation and tourniquet application can alter its relationship to the brachial artery and median nerve. This study used ultrasonography to characterise these effects across sex and ethnicity. Methods: Sixty healthy adults (28 men, 32 women; aged 18–46 years) from South Asian, Middle Eastern and North African (MENA), Sub-Saharan African (SSA), and other backgrounds underwent ultrasonographic assessment (GE LOGIQ system, 12 MHz linear transducer) of MCV diameter and its distance from the brachial artery, median nerve, and skin surface, before and after tourniquet application. Results: Tourniquet application significantly increased MCV diameter and its distance from the brachial artery and median nerve (p < 0.05), with no significant change in skin depth. MCV diameter did not differ significantly by sex; however, after tourniquet application, males showed significantly greater distance from the brachial artery and median nerve than females (p < 0.05). MCV diameter differed significantly across ethnic groups after tourniquet application (one-way ANOVA, p = 0.037), with MENA participants having the largest and SSA participants the smallest mean diameter; no other parameter differed by ethnicity. Anatomical variants included MCV absence (8.3%), MCV coursing deep to the bicipital aponeurosis (3.6% of visualized veins), and the brachial artery or median nerve lying directly beneath the MCV (5.5%). Conclusion: Tourniquet application, sex, and ethnicity significantly influence MCV anatomy and its neurovascular relationships. Ultrasonography reliably detects clinically important variants that could compromise venipuncture safety, supporting its selective use before vascular access in high-risk patients.
SN  - 2214-854X
ER  -