EUS-guided versus percutaneous spleen biopsy: Comparative safety and diagnostic performance in a tertiary center
- 1Department of Gastroenterology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
Abstract
Background and Objectives:: Percutaneous biopsy is the traditional method for diagnosing splenic lesions but carries a risk of hemorrhage due to the organ’s rich vascularity. EUS-guided biopsy has emerged as a minimally invasive alternative that may reduce bleeding risk. This study compared the safety and diagnostic performance of EUS-guided and percutaneous spleen biopsies.
Methods:: We retrospectively analyzed 91 patients who underwent splenic biopsy at a tertiary center between 2015 and 2023 (EUS, n = 63; percutaneous, n = 28). The primary outcome was the occurrence of procedure-related adverse events graded by the Adverse Events in Gastrointestinal Endoscopy (AGREE) classification. Secondary outcomes included tissue adequacy and diagnostic performance. Statistical analyses used Fisher’s and Boschloo tests, Firth-penalized logistic regression, and propensity-score overlap weighting to adjust for confounders.
Results:: Clinically relevant adverse events (AGREE grade ≥2) occurred among 0% of EUS-guided and 10.7% of percutaneous biopsies (absolute risk difference: −10.7%, 95% confidence interval: −21.1% to −0.3%; P = 0.029). After adjustment, EUS-guided biopsy remained independently associated with fewer major adverse events (adjusted odds ratio: 0.09, 95% confidence interval: 0.00 to 0.78; P = 0.047). Diagnostic sensitivity was comparable between EUS and percutaneous biopsy (86.4% vs. 93.3%; P = 0.74), with 100% specificity in both.
Conclusion:: EUS-guided spleen biopsy was associated with a lower rate of clinically relevant adverse events, maintaining comparable diagnostic accuracy. These findings suggest that EUS-guided biopsy is a safer and equally effective alternative for splenic tissue acquisition, warranting validation in larger prospective studies.
Related
- Diagnostic performance of computed tomography-guided percutaneous bone biopsy in musculoskeletal oncology: A single-center cohort study
- Ultrasonic-With-Ballistic Versus Pneumatic Lithotripsy in Percutaneous Nephrolithotomy for 2-4 cm Renal Calculi: A Prospective Quasi-experimental Comparative Study in a Bangladeshi Tertiary-Care Hospital
- Diagnostic performance and safety of EUS-guided liver biopsy: A multicenter Latin American comparative study
- Procedural efficiency, diagnostic yield, and safety of a novel positioning grid combined with a non-coplanar puncture-angle guide for CT-guided percutaneous transthoracic lung biopsy: a retrospective contemporaneous-control study
- Diagnostic performance and clinical integration of an artificial intelligence–assisted ultrasound decision support tool for thyroid nodules at a tertiary cancer centre
BibTeX
@article{lee2026eusguided,
title = {{EUS-guided versus percutaneous spleen biopsy: Comparative safety and diagnostic performance in a tertiary center}},
author = {Junghwan Lee and Tae Jun Song and Yoonchan Lee and Sung Hyun Cho and Gunn Huh and Dongwook Oh and Dong-Wan Seo},
journal = {Endoscopic Ultrasound},
year = {2026},
month = aug,
doi = {10.1097/eus.0000000000000187},
url = {https://doi.org/10.1097/eus.0000000000000187},
note = {CC BY-NC-ND 4.0},
}
RIS
TY - JOUR
TI - EUS-guided versus percutaneous spleen biopsy: Comparative safety and diagnostic performance in a tertiary center
AU - Junghwan Lee
AU - Tae Jun Song
AU - Yoonchan Lee
AU - Sung Hyun Cho
AU - Gunn Huh
AU - Dongwook Oh
AU - Dong-Wan Seo
PY - 2026
DA - 2026/08/17
JO - Endoscopic Ultrasound
DO - 10.1097/eus.0000000000000187
UR - https://doi.org/10.1097/eus.0000000000000187
AB - Background and Objectives:: Percutaneous biopsy is the traditional method for diagnosing splenic lesions but carries a risk of hemorrhage due to the organ’s rich vascularity. EUS-guided biopsy has emerged as a minimally invasive alternative that may reduce bleeding risk. This study compared the safety and diagnostic performance of EUS-guided and percutaneous spleen biopsies. Methods:: We retrospectively analyzed 91 patients who underwent splenic biopsy at a tertiary center between 2015 and 2023 (EUS, n = 63; percutaneous, n = 28). The primary outcome was the occurrence of procedure-related adverse events graded by the Adverse Events in Gastrointestinal Endoscopy (AGREE) classification. Secondary outcomes included tissue adequacy and diagnostic performance. Statistical analyses used Fisher’s and Boschloo tests, Firth-penalized logistic regression, and propensity-score overlap weighting to adjust for confounders. Results:: Clinically relevant adverse events (AGREE grade ≥2) occurred among 0% of EUS-guided and 10.7% of percutaneous biopsies (absolute risk difference: −10.7%, 95% confidence interval: −21.1% to −0.3%; P = 0.029). After adjustment, EUS-guided biopsy remained independently associated with fewer major adverse events (adjusted odds ratio: 0.09, 95% confidence interval: 0.00 to 0.78; P = 0.047). Diagnostic sensitivity was comparable between EUS and percutaneous biopsy (86.4% vs. 93.3%; P = 0.74), with 100% specificity in both. Conclusion:: EUS-guided spleen biopsy was associated with a lower rate of clinically relevant adverse events, maintaining comparable diagnostic accuracy. These findings suggest that EUS-guided biopsy is a safer and equally effective alternative for splenic tissue acquisition, warranting validation in larger prospective studies.
SN - 2303-9027
SN - 2226-7190
ER -