Peer-reviewedCC BY-NC-ND 4.0Endoscopic Ultrasound

EUS-guided versus percutaneous spleen biopsy: Comparative safety and diagnostic performance in a tertiary center

  1. 1Department of Gastroenterology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.

Abstract

Background and Objectives:: Percutaneous biopsy is the traditional method for diagnosing splenic lesions but carries a risk of hemorrhage due to the organ’s rich vascularity. EUS-guided biopsy has emerged as a minimally invasive alternative that may reduce bleeding risk. This study compared the safety and diagnostic performance of EUS-guided and percutaneous spleen biopsies.

Methods:: We retrospectively analyzed 91 patients who underwent splenic biopsy at a tertiary center between 2015 and 2023 (EUS, n = 63; percutaneous, n = 28). The primary outcome was the occurrence of procedure-related adverse events graded by the Adverse Events in Gastrointestinal Endoscopy (AGREE) classification. Secondary outcomes included tissue adequacy and diagnostic performance. Statistical analyses used Fisher’s and Boschloo tests, Firth-penalized logistic regression, and propensity-score overlap weighting to adjust for confounders.

Results:: Clinically relevant adverse events (AGREE grade ≥2) occurred among 0% of EUS-guided and 10.7% of percutaneous biopsies (absolute risk difference: −10.7%, 95% confidence interval: −21.1% to −0.3%; P = 0.029). After adjustment, EUS-guided biopsy remained independently associated with fewer major adverse events (adjusted odds ratio: 0.09, 95% confidence interval: 0.00 to 0.78; P = 0.047). Diagnostic sensitivity was comparable between EUS and percutaneous biopsy (86.4% vs. 93.3%; P = 0.74), with 100% specificity in both.

Conclusion:: EUS-guided spleen biopsy was associated with a lower rate of clinically relevant adverse events, maintaining comparable diagnostic accuracy. These findings suggest that EUS-guided biopsy is a safer and equally effective alternative for splenic tissue acquisition, warranting validation in larger prospective studies.

Related

  1. Diagnostic performance of computed tomography-guided percutaneous bone biopsy in musculoskeletal oncology: A single-center cohort study
    Andreea Minodora Stuparu Adam, Alnuaimi Osama, Alexandru Stere +6
    World journal of radiologyPeer-reviewedCC BY-NCFull textMedical imaging & radiologyEurope PMCPMC
  2. Ultrasonic-With-Ballistic Versus Pneumatic Lithotripsy in Percutaneous Nephrolithotomy for 2-4 cm Renal Calculi: A Prospective Quasi-experimental Comparative Study in a Bangladeshi Tertiary-Care Hospital
    Md. Mahmudul Hasan, Md. Mezbahul Moker Rabin, Mohammad Alomgir +6
    CureusPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  3. Diagnostic performance and safety of EUS-guided liver biopsy: A multicenter Latin American comparative study
    Jose Ignacio Vargas, Javier Uribe, Sara Maquilon +16
    Endoscopic UltrasoundPeer-reviewedCC BY 4.0Full textGeneral medicinePMC
  4. Procedural efficiency, diagnostic yield, and safety of a novel positioning grid combined with a non-coplanar puncture-angle guide for CT-guided percutaneous transthoracic lung biopsy: a retrospective contemporaneous-control study
    Ke Xu, Jiayi Chen, Sijia Deng +2
    Journal of thoracic diseasePeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  5. Diagnostic performance and clinical integration of an artificial intelligence–assisted ultrasound decision support tool for thyroid nodules at a tertiary cancer centre
    Wyanne Law, Junting Zheng, Shannan M. Dickinson +6
    Ultrasound: Journal of the British Medical Ultrasound SocietyPeer-reviewedLicence not statedFull textEndocrinology & metabolismPMC
BibTeX
@article{lee2026eusguided,
  title = {{EUS-guided versus percutaneous spleen biopsy: Comparative safety and diagnostic performance in a tertiary center}},
  author = {Junghwan Lee and Tae Jun Song and Yoonchan Lee and Sung Hyun Cho and Gunn Huh and Dongwook Oh and Dong-Wan Seo},
  journal = {Endoscopic Ultrasound},
  year = {2026},
  month = aug,
  doi = {10.1097/eus.0000000000000187},
  url = {https://doi.org/10.1097/eus.0000000000000187},
  note = {CC BY-NC-ND 4.0},
}
RIS
TY  - JOUR
TI  - EUS-guided versus percutaneous spleen biopsy: Comparative safety and diagnostic performance in a tertiary center
AU  - Junghwan Lee
AU  - Tae Jun Song
AU  - Yoonchan Lee
AU  - Sung Hyun Cho
AU  - Gunn Huh
AU  - Dongwook Oh
AU  - Dong-Wan Seo
PY  - 2026
DA  - 2026/08/17
JO  - Endoscopic Ultrasound
DO  - 10.1097/eus.0000000000000187
UR  - https://doi.org/10.1097/eus.0000000000000187
AB  - Background and Objectives:: Percutaneous biopsy is the traditional method for diagnosing splenic lesions but carries a risk of hemorrhage due to the organ’s rich vascularity. EUS-guided biopsy has emerged as a minimally invasive alternative that may reduce bleeding risk. This study compared the safety and diagnostic performance of EUS-guided and percutaneous spleen biopsies.  Methods:: We retrospectively analyzed 91 patients who underwent splenic biopsy at a tertiary center between 2015 and 2023 (EUS, n = 63; percutaneous, n = 28). The primary outcome was the occurrence of procedure-related adverse events graded by the Adverse Events in Gastrointestinal Endoscopy (AGREE) classification. Secondary outcomes included tissue adequacy and diagnostic performance. Statistical analyses used Fisher’s and Boschloo tests, Firth-penalized logistic regression, and propensity-score overlap weighting to adjust for confounders.  Results:: Clinically relevant adverse events (AGREE grade ≥2) occurred among 0% of EUS-guided and 10.7% of percutaneous biopsies (absolute risk difference: −10.7%, 95% confidence interval: −21.1% to −0.3%; P = 0.029). After adjustment, EUS-guided biopsy remained independently associated with fewer major adverse events (adjusted odds ratio: 0.09, 95% confidence interval: 0.00 to 0.78; P = 0.047). Diagnostic sensitivity was comparable between EUS and percutaneous biopsy (86.4% vs. 93.3%; P = 0.74), with 100% specificity in both.  Conclusion:: EUS-guided spleen biopsy was associated with a lower rate of clinically relevant adverse events, maintaining comparable diagnostic accuracy. These findings suggest that EUS-guided biopsy is a safer and equally effective alternative for splenic tissue acquisition, warranting validation in larger prospective studies.
SN  - 2303-9027
SN  - 2226-7190
ER  -