Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 7 min ago
Peer-reviewedCC BY-NC-ND 4.0Journal of Cardiovascular Electrophysiology

Feasibility, Safety, and Efficacy of Pulsed Field Ablation for Ventricular Arrhythmias: Insights From a Large Health System Registry in the United States

11 more authors
4 affiliations
  1. 1Department of Cardiovascular Medicine Mayo Clinic Rochester Minnesota USA
  2. 2Department of Cardiovascular Medicine Mayo Clinic Phoenix Arizona USA
  3. 3Division Chair‐Cardiothoracic Radiology Mayo Clinic Phoenix Arizona USA
  4. 4Department of Cardiovascular Medicine Mayo Clinic Jacksonville Florida USA

Abstract

Background: Pulsed field ablation (PFA) is an emerging non‐thermal ablation modality with proven safety in atrial arrhythmia ablation. However, data on its performance for ventricular arrhythmias (VA) remain limited.

Objective: To evaluate the feasibility, safety, and efficacy of PFA for complex VA in a multicenter real‐world US registry.

Methods: This retrospective study included consecutive patients undergoing PFA for ventricular tachycardia (VT) or premature ventricular contractions (PVCs) at three Mayo Clinic centers (April 2024 to July 2025). The primary feasibility outcome was the successful delivery of PFA lesions to the intended target substrate. Primary efficacy outcomes included acute procedural success; sustained VT recurrence requiring implantable cardioverter‐defibrillator (ICD) shocks or multiple antitachycardia pacing therapies; and ≥ 80% reduction in PVC burden. Safety outcomes included procedural complications, valvular function, thromboembolic events, renal function, and conduction disturbances.

Results: Twenty‐six patients were included (13 PVC, 13 VT). Acute success was achieved in all VT ablations (69.2% complete; 30.8% partial) and in 92.3% of PVC ablations. Complications occurred in 11.5% of patients (transient LBBB [n = 1] and vascular complications [n = 2]). No thromboembolic events, intracardiac thrombus, or acute kidney injury were observed. Lesions near the mitral valve apparatus did not worsen mitral regurgitation, including in patients with pre‐existing valve disease. After a median follow‐up of 365 days, one patient experienced VT recurrence requiring ICD shocks. Estimated recurrence‐free survival after VT ablation was 61.5% at 12 months; 58.3% of PVC patients achieved ≥ 80% burden reduction.

Conclusion: PFA for VA appears feasible and acutely effective, with a low rate of procedure‐related complications. While acute success was high, long‐term outcomes were acceptable for VT ablation and relatively modest for PVC ablation, highlighting the need for continued refinement of technology and energy‐delivery strategies. Larger prospective studies are warranted.

Related

  1. Dual-Energy Pulsed Field and Radiofrequency Ablation With a Contact Force-Sensing Focal Catheter for Ventricular Arrhythmias: Initial Clinical Experience
    A. Darma, S.-E. Waezsada, N. Trajkovska +10
    medRxivPreprintAll rights reservedFull textCardiovascular medicinemedRxiv
  2. Loperamide-Associated Ventricular Arrhythmias
    Jonaz Font, Joachim Alexandre, Charles Dolladille +2
    Journal of the American College of CardiologyPeer-reviewedLicence not stated2 citedCardiovascular medicineHAL
  3. CCL4 Enhances Left Stellate Ganglion Sympathetic Activity and Aggravates Ventricular Arrhythmias After Myocardial Ischemia Reperfusion
    Changyi Wang, Wanyue Sang, Zizhuo Zhang +3
    BiomedicinesPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. Metabolic stress exacerbates Ca2+ dysregulation and arrhythmias in catecholaminergic polymorphic ventricular tachycardia
    Valeria Gomez, Arpita Deb, Zhuoxin Li +7
    Experimental physiologyPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  5. Myocardial Work Index Dispersion as a Potential Predictor of Ventricular Arrhythmias in Patients with Heart Failure with Reduced Ejection Fraction
    Martyna Dąbrowska, Magdalena Potapowicz-Krysztofiak, Patrycja Życzkowska +6
    BiomedicinesPeer-reviewedCC BYFull textGeneral medicineEurope PMC
BibTeX
@article{prasitlumkum2026feasibility,
  title = {{Feasibility, Safety, and Efficacy of Pulsed Field Ablation for Ventricular Arrhythmias: Insights From a Large Health System Registry in the United States}},
  author = {Narut Prasitlumkum and Juan F. Rodriguez‐Riascos and Hema Vemulapalli and Aakash Somappa and Camilo A. Estrada‐Vargas and Olubadewa A. Fatunde and Carlos A. Rojas and Poojan Prajapati and Keerthika Vijayakumar and Suraj Kapa and Duy Nguyen and Samuel Asirvatham and Malini Madhavan and Christopher McLeod and Hicham Z. El Masry and Abhishek J. Deshmukh and Danesh K. Kella and Ammar M. Killu and Siva K. Mulpuru and Mayank Sardana and Luis R. Scott and Alan M. Sugrue and Komandoor Srivathsan},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2026},
  month = sep,
  doi = {10.1111/jce.70503},
  url = {https://doi.org/10.1111/jce.70503},
  note = {CC BY-NC-ND 4.0},
}
RIS
TY  - JOUR
TI  - Feasibility, Safety, and Efficacy of Pulsed Field Ablation for Ventricular Arrhythmias: Insights From a Large Health System Registry in the United States
AU  - Narut Prasitlumkum
AU  - Juan F. Rodriguez‐Riascos
AU  - Hema Vemulapalli
AU  - Aakash Somappa
AU  - Camilo A. Estrada‐Vargas
AU  - Olubadewa A. Fatunde
AU  - Carlos A. Rojas
AU  - Poojan Prajapati
AU  - Keerthika Vijayakumar
AU  - Suraj Kapa
AU  - Duy Nguyen
AU  - Samuel Asirvatham
AU  - Malini Madhavan
AU  - Christopher McLeod
AU  - Hicham Z. El Masry
AU  - Abhishek J. Deshmukh
AU  - Danesh K. Kella
AU  - Ammar M. Killu
AU  - Siva K. Mulpuru
AU  - Mayank Sardana
AU  - Luis R. Scott
AU  - Alan M. Sugrue
AU  - Komandoor Srivathsan
PY  - 2026
DA  - 2026/09/15
JO  - Journal of Cardiovascular Electrophysiology
DO  - 10.1111/jce.70503
UR  - https://doi.org/10.1111/jce.70503
AB  - Background: Pulsed field ablation (PFA) is an emerging non‐thermal ablation modality with proven safety in atrial arrhythmia ablation. However, data on its performance for ventricular arrhythmias (VA) remain limited.  Objective: To evaluate the feasibility, safety, and efficacy of PFA for complex VA in a multicenter real‐world US registry.  Methods: This retrospective study included consecutive patients undergoing PFA for ventricular tachycardia (VT) or premature ventricular contractions (PVCs) at three Mayo Clinic centers (April 2024 to July 2025). The primary feasibility outcome was the successful delivery of PFA lesions to the intended target substrate. Primary efficacy outcomes included acute procedural success; sustained VT recurrence requiring implantable cardioverter‐defibrillator (ICD) shocks or multiple antitachycardia pacing therapies; and ≥ 80% reduction in PVC burden. Safety outcomes included procedural complications, valvular function, thromboembolic events, renal function, and conduction disturbances.  Results: Twenty‐six patients were included (13 PVC, 13 VT). Acute success was achieved in all VT ablations (69.2% complete; 30.8% partial) and in 92.3% of PVC ablations. Complications occurred in 11.5% of patients (transient LBBB [n = 1] and vascular complications [n = 2]). No thromboembolic events, intracardiac thrombus, or acute kidney injury were observed. Lesions near the mitral valve apparatus did not worsen mitral regurgitation, including in patients with pre‐existing valve disease. After a median follow‐up of 365 days, one patient experienced VT recurrence requiring ICD shocks. Estimated recurrence‐free survival after VT ablation was 61.5% at 12 months; 58.3% of PVC patients achieved ≥ 80% burden reduction.  Conclusion: PFA for VA appears feasible and acutely effective, with a low rate of procedure‐related complications. While acute success was high, long‐term outcomes were acceptable for VT ablation and relatively modest for PVC ablation, highlighting the need for continued refinement of technology and energy‐delivery strategies. Larger prospective studies are warranted.
SN  - 1045-3873
SN  - 1540-8167
ER  -