Skip to content
DraconiticResearch
Search Sources API
186,631 studies31 sourcesUpdated 42 min ago
Peer-reviewedCC BY-NCMedical devices (Auckland, N.Z.)

Validation of an AI-Driven Sputum Analysis Platform for Accurate and Reliable Tuberculosis Detection in South-Western Uganda.

  1. 1Department of Pathology, Mbarara University of Science and Technology (MUST), Mbarara, Uganda.
  2. 2SRF Research and Training Centers, Mbarara, Uganda.
  3. 3Department of Laboratory Services, Mbarara Regional Referral Hospital (MRRH), Mbarara, Uganda.

Abstract

Background

Ziehl-Neelsen (ZN) sputum smear microscopy remains an accessible method for detecting acid-fast bacilli (AFB), but its interpretation is dependent on specimen quality and trained microscopy personnel. Artificial intelligence (AI) may provide a microscopy reading aid that supports consistent identification of AFB-positive and AFB-negative smear images.Objective

To evaluate transfer-learning deep learning models for classification of AFB-positive and AFB-negative digitized ZN-stained sputum smear images generated in a Ugandan regional referral laboratory.Methods

A retrospective laboratory-based cross-sectional study used 512 archived digitized ZN-stained sputum smear images from Mbarara Regional Referral Hospital. The dataset contained 256 AFB-positive and 256 AFB-negative images and was partitioned by stratified sampling into training (n=358), validation (n=77), and an internal hold-out test set (n=77). ResNet-50 V2, DenseNet-121, and Swin Transformer-Tiny models were trained using ImageNet-pretrained weights in PyTorch. Performance was assessed using sensitivity, specificity, accuracy, positive predictive value (PPV), negative predictive value (NPV), F1-score, and ROC-AUC.Results

On the internal test set, Swin Transformer-Tiny achieved 97.40% accuracy, 97.37% sensitivity, 97.44% specificity, 97.37% PPV, 97.44% NPV, 97.37% F1-score, and ROC-AUC 0.9939. DenseNet-121 achieved 88.31% accuracy, 84.21% sensitivity, 92.31% specificity, and ROC-AUC 0.9730. ResNet-50 V2 achieved 85.71% accuracy, 81.58% sensitivity, 89.74% specificity, and ROC-AUC 0.9555. Wilson 95% confidence intervals were calculated for the threshold-based metrics.Conclusion

The models demonstrated promising internal performance for classification of microscopy-defined AFB status. Swin Transformer-Tiny had the highest observed performance, but the small, balanced, single-centre internal test set and use of routine microscopy labels rather than an independent microbiological reference standard limit clinical interpretation. The platform should therefore be considered an AI-assisted microscopy reading aid rather than an autonomous tuberculosis diagnostic system. Prospective, multicentre evaluation using patient/specimen-level separation, independent microbiological reference standards, and multiple blinded readers is required before clinical deployment.

Related

  1. Development and Validation of a Point-of-Care Triage Scorecard to Enhance Tuberculosis Case Detection During Active Community Screening in Yogyakarta, Indonesia
    D. Catrianiningsih, F. Felisia, A. S. Abdalla +5
    medRxivPreprintCC BYFull textInfectious diseasemedRxiv
  2. Cross-Cultural Adaptation and Psychometric Validation of the Arabic Duruöz Hand Index: A Reliable Patient-Reported Measure for Hand Disability in Arabic-Speaking Populations
    Marc Boutros, Guy Awad, Caren Hassan +6
    Hand (New York, N.Y.)Peer-reviewedLicence not statedFull textSurgery & anaesthesiaPMC
  3. Reliable Detection, Unreliable Clinical Decision-making: Artificial Intelligence Models in Burn Assessment
    Ibrahim Güler, Uzay Cambaz, Armin Kraus +2
    Plastic and reconstructive surgery. Global openPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMC
  4. Caputo fractional-order differential equations for tuberculosis transmission and relapse dynamics with empirical validation
    Mideksa Tola Jiru, Sathish Kumar Kumaravel, Marimuthu Dharmalingam +2
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textEpidemiology & public healthCrossref
  5. An Artificial Intelligence Supervision Program to Improve Video-Observed Therapy for Managing Tuberculosis Treatment: Development and Validation Study
    Xujun Guo, Junbo Bai, Xiang Wan +6
    Tropical medicine and infectious diseasePeer-reviewedCC BYFull textGeneral medicineEurope PMC
BibTeX
@article{tumwesigye2026validation,
  title = {{Validation of an AI-Driven Sputum Analysis Platform for Accurate and Reliable Tuberculosis Detection in South-Western Uganda.}},
  author = {Habert Tumwesigye and Daniel Atwine and Raymond Atwine and Abraham Birungi and Caroline Birungi and Esther Munguciada and Phionah Nabimanya and Joseph Akandwanaho and Benard Ochama and Yekosani Mitala},
  journal = {Medical devices (Auckland, N.Z.)},
  year = {2026},
  month = oct,
  doi = {10.2147/mder.s639007},
  url = {https://europepmc.org/article/MED/42899212},
  note = {CC BY-NC},
}
RIS
TY  - JOUR
TI  - Validation of an AI-Driven Sputum Analysis Platform for Accurate and Reliable Tuberculosis Detection in South-Western Uganda.
AU  - Habert Tumwesigye
AU  - Daniel Atwine
AU  - Raymond Atwine
AU  - Abraham Birungi
AU  - Caroline Birungi
AU  - Esther Munguciada
AU  - Phionah Nabimanya
AU  - Joseph Akandwanaho
AU  - Benard Ochama
AU  - Yekosani Mitala
PY  - 2026
DA  - 2026/10/15
JO  - Medical devices (Auckland, N.Z.)
DO  - 10.2147/mder.s639007
UR  - https://europepmc.org/article/MED/42899212
AB  - Background  Ziehl-Neelsen (ZN) sputum smear microscopy remains an accessible method for detecting acid-fast bacilli (AFB), but its interpretation is dependent on specimen quality and trained microscopy personnel. Artificial intelligence (AI) may provide a microscopy reading aid that supports consistent identification of AFB-positive and AFB-negative smear images.Objective  To evaluate transfer-learning deep learning models for classification of AFB-positive and AFB-negative digitized ZN-stained sputum smear images generated in a Ugandan regional referral laboratory.Methods  A retrospective laboratory-based cross-sectional study used 512 archived digitized ZN-stained sputum smear images from Mbarara Regional Referral Hospital. The dataset contained 256 AFB-positive and 256 AFB-negative images and was partitioned by stratified sampling into training (n=358), validation (n=77), and an internal hold-out test set (n=77). ResNet-50 V2, DenseNet-121, and Swin Transformer-Tiny models were trained using ImageNet-pretrained weights in PyTorch. Performance was assessed using sensitivity, specificity, accuracy, positive predictive value (PPV), negative predictive value (NPV), F1-score, and ROC-AUC.Results  On the internal test set, Swin Transformer-Tiny achieved 97.40% accuracy, 97.37% sensitivity, 97.44% specificity, 97.37% PPV, 97.44% NPV, 97.37% F1-score, and ROC-AUC 0.9939. DenseNet-121 achieved 88.31% accuracy, 84.21% sensitivity, 92.31% specificity, and ROC-AUC 0.9730. ResNet-50 V2 achieved 85.71% accuracy, 81.58% sensitivity, 89.74% specificity, and ROC-AUC 0.9555. Wilson 95% confidence intervals were calculated for the threshold-based metrics.Conclusion  The models demonstrated promising internal performance for classification of microscopy-defined AFB status. Swin Transformer-Tiny had the highest observed performance, but the small, balanced, single-centre internal test set and use of routine microscopy labels rather than an independent microbiological reference standard limit clinical interpretation. The platform should therefore be considered an AI-assisted microscopy reading aid rather than an autonomous tuberculosis diagnostic system. Prospective, multicentre evaluation using patient/specimen-level separation, independent microbiological reference standards, and multiple blinded readers is required before clinical deployment.
SN  - 1179-1470
ER  -