Skip to content
DraconiticResearch
Search Sources API
201,683 studies31 sourcesUpdated 56 min ago
PreprintCC BY 4.0arXiv

Magnetic Johnson noise from arbitrarily shaped conductors: experimental validation of the fluctuation-dissipation finite-element method

Abstract

Magnetic Johnson noise--magnetic noise caused by thermal current fluctuations in conducting materials--can interfere with measurements and limit their sensitivity. As the sensitivity of experiments increases, it becomes increasingly important to accurately estimate the magnetic Johnson noise from experimental components with complex shapes during both the design and analysis phases. A particularly powerful approach is to combine the fluctuation-dissipation theorem with finite-element calculations. This versatile approach can be used to calculate the magnetic Johnson noise from conductors of arbitrary geometry for a wide range of frequencies and for magnetic field detectors with general geometries, such as a finite-sized loop or a gradiometer. Using a SQUID gradiometer array, we measured the magnetic Johnson noise from conductors with complex geometries and compared the results with calculations performed using this method. The calculations reproduce both the measured noise amplitude and its frequency dependence, providing an experimental validation of this method. We also performed a detailed analysis of how the geometry and material parameters affect the frequency dependence of magnetic Johnson noise.

Related

  1. Fluctuation-dissipation relation in branching particle systems
    Tom Michoel
    arXivPreprintCC BY-SA 4.0Full textCell biologyBiological & medical physicsarXiv
  2. Generalized fluctuation-dissipation theorem and Einstein relation in rotating equilibrium
    Shuo Fang, Shi Pu
    arXivPreprintCC BY 4.0Full textHigh-energy & particle physicsNuclear physicsarXiv
  3. Kinetic Fluctuation-Dissipation Relation in collisionless plasmas: a correlated noise source
    Fabio Moretti, Oreste Pezzi, Simone Benella +6
    arXivPreprintCC BY 4.0Full textPlasma physicsarXiv
  4. Fluctuation-dissipation relations in isotropic turbulence from Kraichnan's fully resolved DIA closure
    Elias Kohler, Matthias Fuchs
    arXivPreprintCC BY 4.0Full textFluid dynamicsarXiv
  5. Fluctuation-dissipation structure of quantum geometry
    Per Moosavi
    arXivPreprintarXiv licenceFull textMathematical physicsCondensed matterarXiv
BibTeX
@misc{clayton2026magnetic,
  title = {{Magnetic Johnson noise from arbitrarily shaped conductors: experimental validation of the fluctuation-dissipation finite-element method}},
  author = {S. M. Clayton and Y. J. Kim and T. E. Chupp and A. Epstein and J. M. Feltman and A. Fratangelo and T. M. Ito and I. J. Rhudy and F. H. Sottrel and W. A. Terrano and K. L. Wood},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2610.42113},
  eprint = {2610.42113},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.42113},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - Magnetic Johnson noise from arbitrarily shaped conductors: experimental validation of the fluctuation-dissipation finite-element method
AU  - S. M. Clayton
AU  - Y. J. Kim
AU  - T. E. Chupp
AU  - A. Epstein
AU  - J. M. Feltman
AU  - A. Fratangelo
AU  - T. M. Ito
AU  - I. J. Rhudy
AU  - F. H. Sottrel
AU  - W. A. Terrano
AU  - K. L. Wood
PY  - 2026
DA  - 2026/10/30
PB  - arXiv
DO  - 10.48550/arxiv.2610.42113
UR  - https://arxiv.org/abs/2610.42113
AB  - Magnetic Johnson noise--magnetic noise caused by thermal current fluctuations in conducting materials--can interfere with measurements and limit their sensitivity. As the sensitivity of experiments increases, it becomes increasingly important to accurately estimate the magnetic Johnson noise from experimental components with complex shapes during both the design and analysis phases. A particularly powerful approach is to combine the fluctuation-dissipation theorem with finite-element calculations. This versatile approach can be used to calculate the magnetic Johnson noise from conductors of arbitrary geometry for a wide range of frequencies and for magnetic field detectors with general geometries, such as a finite-sized loop or a gradiometer. Using a SQUID gradiometer array, we measured the magnetic Johnson noise from conductors with complex geometries and compared the results with calculations performed using this method. The calculations reproduce both the measured noise amplitude and its frequency dependence, providing an experimental validation of this method. We also performed a detailed analysis of how the geometry and material parameters affect the frequency dependence of magnetic Johnson noise.
ER  -