Skip to content
DraconiticResearch
Search Sources API
203,203 studies31 sourcesUpdated 56 min ago
PreprintCC BY 4.0arXiv

A high-speed anamorphic pupil-conjugate slit spectrograph for rapid, self-luminous sources

Abstract

We present a slit imaging spectrograph whose wavelength registration is a property of the instrument rather than of the pointing of the fore-optic or the position of the source. An internal telecentric 4f relay places the system stop within the instrument while a cylindrical lens places the slit aperture at a plane where transverse position encodes source angle only (an A = 0 conjugate in the ABCD matrix formulation). As a result, the lateral motion of the source or the pointing of the fore-optic does not cause the spectral image illuminating the sensor to wander, thus eliminating any non-physical registration of chemical species not present in the event and the need for on-the-fly recalibration. Additionally, the use of a high-speed CMOS camera eliminates temporally averaged spectral lines and aliasing noise. We characterize wavelength calibration (He discharge lamp, quadratic fit, RMS residual 0.12 nm, verified with Ne discharge lamp, same calibration, RMS residual 0.13 nm), spectral resolution (R ≈ 639, FWHM 0.92 nm at the optimal slit width setting, R ≈ 783, FWHM 0.75 nm at the instrument profile floor), and pointing invariance (He 587.6 nm line wander 0.29 nm RMS, 1.03 nm peak-to-peak, a nearly 100x reduction relative to the same instrument with the aperture stop at the fore-optic pupil). We perform combustion spectroscopy on ignited nitrocellulose at 10 kHz, 99 μs exposure time, identifying Na, K, Ca, CaOH, and Rb chemical species using the unchanged wavelength calibration transferred from the helium discharge lamp.

Related

  1. KM3NeT/ARCA stacking search for high-energy neutrino point sources: the case of ultra-luminous infrared galaxies and blazars
    O Adriani, A Albert, A.R Alhebsi +289
    HALPreprintCC BY 4.0Full textHigh-energy astrophysicsGeneral physicsHALarXiv
  2. The optical high-resolution spectral archive of the HERMES spectrograph mounted on the 1.2m Mercator telescope
    Hans Van Winckel, Saskia Prins, Gert Raskin +13
    Astronomy & AstrophysicsPeer-reviewedPublisher termsApplied physics & instrumentationCrossref
  3. AT2025agpz in Rubin commissioning data: distinguishing a luminous interacting supernova from nuclear transients in compact galaxies
    C.R Angus, M Quilt, H.F Stevance +37
    HALPreprintLicence not statedGeneral astronomyGeneral physicsHAL
  4. A Finely-Binned Measurement of the Connected Even-Parity Galaxy 4-Point Correlation Function of DESI Year 1 Luminous Red Galaxies
    William Ortolá Leonard, Alex Krolewski, Zachary Slepian +46
    HALPreprintarXiv licenceFull textCosmologyGeneral physicsHALarXiv
  5. A Little Red Dot emerging from a nitrogen-rich UV-luminous galaxy with Very Massive Stars
    Alberto Torralba, Jorryt Matthee, Rui Marques-Chaves +13
    arXivPreprintCC BY 4.0Full textGalaxiesGeneral physicsarXivHAL
BibTeX
@misc{vayner2026highspeed,
  title = {{A high-speed anamorphic pupil-conjugate slit spectrograph for rapid, self-luminous sources}},
  author = {Matthew Vayner and Kyle D. Gilroy},
  howpublished = {arXiv},
  year = {2026},
  month = aug,
  doi = {10.48550/arxiv.2608.29791},
  eprint = {2608.29791},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2608.29791},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - A high-speed anamorphic pupil-conjugate slit spectrograph for rapid, self-luminous sources
AU  - Matthew Vayner
AU  - Kyle D. Gilroy
PY  - 2026
DA  - 2026/08/30
PB  - arXiv
DO  - 10.48550/arxiv.2608.29791
UR  - https://arxiv.org/abs/2608.29791
AB  - We present a slit imaging spectrograph whose wavelength registration is a property of the instrument rather than of the pointing of the fore-optic or the position of the source. An internal telecentric 4f relay places the system stop within the instrument while a cylindrical lens places the slit aperture at a plane where transverse position encodes source angle only (an A = 0 conjugate in the ABCD matrix formulation). As a result, the lateral motion of the source or the pointing of the fore-optic does not cause the spectral image illuminating the sensor to wander, thus eliminating any non-physical registration of chemical species not present in the event and the need for on-the-fly recalibration. Additionally, the use of a high-speed CMOS camera eliminates temporally averaged spectral lines and aliasing noise. We characterize wavelength calibration (He discharge lamp, quadratic fit, RMS residual 0.12 nm, verified with Ne discharge lamp, same calibration, RMS residual 0.13 nm), spectral resolution (R ≈ 639, FWHM 0.92 nm at the optimal slit width setting, R ≈ 783, FWHM 0.75 nm at the instrument profile floor), and pointing invariance (He 587.6 nm line wander 0.29 nm RMS, 1.03 nm peak-to-peak, a nearly 100x reduction relative to the same instrument with the aperture stop at the fore-optic pupil). We perform combustion spectroscopy on ignited nitrocellulose at 10 kHz, 99 μs exposure time, identifying Na, K, Ca, CaOH, and Rb chemical species using the unchanged wavelength calibration transferred from the helium discharge lamp.
ER  -