Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 9 min ago
PreprintCC BY 4.0arXiv

Adaptive Record Consistency in a Schulman-Type Model

Abstract

Adaptive measurements test whether a retrocausal model preserves observable records when experiments are connected by classical feedback. We establish exact and quantitative composition constraints for a finite-width, coplanar Schulman-type source with positive wrapped-Cauchy propagation weights. Raw segment composition admits an explicit adaptive signalling witness. A uniquely determined scalar correction preserves recorded continuations, and a detector with preparation memory implements this correction while retaining the source correlations. For common, independently prepared terminal detectors coupled to the source through arrival angles, exact calibration forces equal-mass antipodal atomic responses. Under setting-only raw feedback, the sharp minimum worst disturbance of an earlier record is ε⋆(0)=[2cosh(2Γ)]−1, where Γ is the total source-path width. We derive explicit finite-error bounds and prove linear small-error improvement. For four settings at Γ=0.4, a uniform reduction over arbitrary nonnegative response measures and a continuous polynomial certificate establish ε⋆(δ)=ε⋆(0)−C0.4δ+O(δ2), with C0.4≃9.351091771057010. A positive five-atom detector attains this coefficient. The results quantify the compatibility of isolated-source accuracy and adaptive record preservation, and provide precise design conditions for retrocausal apparatus models with explicit preparation, memory, and control.

Related

  1. Record consistency under repeated readout and apparatus composition
    D. M. Theshan N. Weerasinghe
    arXivPreprintCC BY 4.0Full textQuantum physics & quantum informationarXiv
  2. Collapse and causality in generalised trace dynamics: record selection in Connes time and the causal consistency of emergent records
    Tejinder P. Singh
    arXivPreprintarXiv licenceFull textAtomic, molecular & optical physicsarXiv
  3. A note on the holographic consistency of DGKT-type vacua with h2,1=0
    Filippo Revello, Farah Verbeure
    arXivPreprintCC BY 4.0Full textHigh-energy & particle physicsarXiv
  4. Two preregistered datasets on production-type labelling in the ENTSO-E Transparency Platform: multi-fuel reporting, register vintages, persistent misclassification, and cross-product consistency
    Eirik Botten Nicolaysen
    arXivPreprintCC BY 4.0Full textStatistical & nonlinear physicsarXiv
  5. The Type-I Seesaw as a Relativistic Fermionic Proximity Effect: Spectral Moments, EFT Consistency, and Sterile-Sector Reconstruction
    Jianlong Lu
    arXivPreprintCC BY 4.0Full textMathematical physicsHigh-energy & particle physicsarXiv
BibTeX
@misc{weerasinghe2026adaptive,
  title = {{Adaptive Record Consistency in a Schulman-Type Model}},
  author = {D. M. Theshan N. Weerasinghe},
  howpublished = {arXiv},
  year = {2026},
  month = sep,
  doi = {10.48550/arxiv.2609.17607},
  eprint = {2609.17607},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2609.17607},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - Adaptive Record Consistency in a Schulman-Type Model
AU  - D. M. Theshan N. Weerasinghe
PY  - 2026
DA  - 2026/09/19
PB  - arXiv
DO  - 10.48550/arxiv.2609.17607
UR  - https://arxiv.org/abs/2609.17607
AB  - Adaptive measurements test whether a retrocausal model preserves observable records when experiments are connected by classical feedback. We establish exact and quantitative composition constraints for a finite-width, coplanar Schulman-type source with positive wrapped-Cauchy propagation weights. Raw segment composition admits an explicit adaptive signalling witness. A uniquely determined scalar correction preserves recorded continuations, and a detector with preparation memory implements this correction while retaining the source correlations. For common, independently prepared terminal detectors coupled to the source through arrival angles, exact calibration forces equal-mass antipodal atomic responses. Under setting-only raw feedback, the sharp minimum worst disturbance of an earlier record is ε_⋆(0)=[2cosh(2Γ)]^−1, where Γ is the total source-path width. We derive explicit finite-error bounds and prove linear small-error improvement. For four settings at Γ=0.4, a uniform reduction over arbitrary nonnegative response measures and a continuous polynomial certificate establish ε_⋆(δ)=ε_⋆(0)−C_0.4δ+O(δ^2), with C_0.4≃9.351091771057010. A positive five-atom detector attains this coefficient. The results quantify the compatibility of isolated-source accuracy and adaptive record preservation, and provide precise design conditions for retrocausal apparatus models with explicit preparation, memory, and control.
ER  -