Delayed Extensor Apparatus Reconstruction for Post–Burn Digital Extension Loss in a Pediatric Patient
- 1From the Faculty of Medicine, Medical University of Warsaw, Warsaw, Poland
- 2Department of Burns and Plastic Surgery, Gandhi Medical College, Bhopal, Madhya Pradesh, India.
Abstract
Late sequelae of pediatric hand burns may include occult damage to the digital extensor apparatus beneath healed scar tissue. The digital extensor apparatus is a complex anatomical system composed of interconnected components that function together to produce coordinated finger extension at interphalangeal joints. Injury to this system may remain clinically unrecognized during acute burn management and present later as isolated extension loss despite preserved joint suppleness. We report the case of a 10-year-old girl who presented 2 years after a flame burn involving the dorsum of the left hand with inability to actively extend the index and middle fingers. Clinical examination demonstrated absent active extension at the proximal and distal interphalangeal joints, whereas passive motion, sensation, and vascularity were preserved. Overlying skin was supple, though scarred and variably pigmented. Radiographs demonstrated mild proximal interphalangeal joint subluxation of the middle finger without other osseous abnormality. Surgical exploration revealed loss of functional continuity of the digital extensor apparatus distally. Delayed reconstruction was performed using an ipsilateral palmaris longus tendon graft to restore coordinated extension. Temporary axial K-wire immobilization was maintained for 2 weeks, followed by structured rehabilitation. At final follow-up, the patient achieved approximately 80% recovery of active extension, enabling writing and functional grasp. This case underscores the importance of early recognition of occult extensor apparatus damage following pediatric hand burns to prevent functional disability. However, delayed reconstruction can still yield meaningful functional recovery when joint mobility and neurovascular integrity are preserved.
Related
- Extensor Mechanism Reconstruction Following Periprosthetic Joint Infection After Total Knee Arthroplasty: A Systematic Review
- Clinical Characteristics and Management of Pediatric Facial Wounds with Documented Infection or Delayed Presentation: A 25-Year Retrospective Case Series
- Case Report: Conservative management of pediatric thyroid abscess with multispatial extension and transient thyrotoxicosis
- Complex Scrotal Reconstruction in Fournier's Gangrene Using a Two-Stage Delayed Bilateral Medial Thigh Skin Flap Technique: A Case Report.
- A novel strategy for reconstruction of AORI type III proximal tibial defects : surface-type knee reconstruction following defect reconstruction with 3D-printed extension-stem augment.
BibTeX
@article{bhatnagar2026delayed,
title = {{Delayed Extensor Apparatus Reconstruction for Post–Burn Digital Extension Loss in a Pediatric Patient}},
author = {Avyesh Bhatnagar and Arun Bhatnagar},
journal = {Plastic and Reconstructive Surgery Global Open},
year = {2026},
month = nov,
doi = {10.1097/gox.0000000000008283},
url = {https://doi.org/10.1097/gox.0000000000008283},
note = {CC BY-NC-ND 4.0},
}
RIS
TY - JOUR
TI - Delayed Extensor Apparatus Reconstruction for Post–Burn Digital Extension Loss in a Pediatric Patient
AU - Avyesh Bhatnagar
AU - Arun Bhatnagar
PY - 2026
DA - 2026/11/12
JO - Plastic and Reconstructive Surgery Global Open
DO - 10.1097/gox.0000000000008283
UR - https://doi.org/10.1097/gox.0000000000008283
AB - Late sequelae of pediatric hand burns may include occult damage to the digital extensor apparatus beneath healed scar tissue. The digital extensor apparatus is a complex anatomical system composed of interconnected components that function together to produce coordinated finger extension at interphalangeal joints. Injury to this system may remain clinically unrecognized during acute burn management and present later as isolated extension loss despite preserved joint suppleness. We report the case of a 10-year-old girl who presented 2 years after a flame burn involving the dorsum of the left hand with inability to actively extend the index and middle fingers. Clinical examination demonstrated absent active extension at the proximal and distal interphalangeal joints, whereas passive motion, sensation, and vascularity were preserved. Overlying skin was supple, though scarred and variably pigmented. Radiographs demonstrated mild proximal interphalangeal joint subluxation of the middle finger without other osseous abnormality. Surgical exploration revealed loss of functional continuity of the digital extensor apparatus distally. Delayed reconstruction was performed using an ipsilateral palmaris longus tendon graft to restore coordinated extension. Temporary axial K-wire immobilization was maintained for 2 weeks, followed by structured rehabilitation. At final follow-up, the patient achieved approximately 80% recovery of active extension, enabling writing and functional grasp. This case underscores the importance of early recognition of occult extensor apparatus damage following pediatric hand burns to prevent functional disability. However, delayed reconstruction can still yield meaningful functional recovery when joint mobility and neurovascular integrity are preserved.
SN - 2169-7574
ER -