Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 23 min ago
Peer-reviewedCC BY-NCClinical optometry

Practice-Level Implementation of 0.4% Pilocarpine for Presbyopia: A Multicenter, Single-Arm Pilot Study of Key Practice Outcomes.

4 affiliations
  1. 1Family First Vision Care LLC, Cleveland, OH, USA.
  2. 2Family First Vision Care LLC, Canton, GA, USA.
  3. 3Family First Vision Care LLC, Schaumburg, IL, USA.
  4. 4Medical Affairs, Orasis Pharmaceuticals, Inc., Ponte Vedra, FL, USA.

Abstract

Purpose

Despite the growing availability of pharmacologic options for presbyopia management, the practice-level implications of prescribing miotic agents within an optometric setting remain largely unexplored. Practitioners have expressed concern that prescribing these agents might reduce the use or purchase of optical corrective devices, or otherwise disrupt established revenue streams. The Presbyopia Pathway Implementation Pilot was undertaken to address these concerns using real-world, practice-based data.Patients and methods

This multicenter, single-arm, open-label pilot study assessed the impact of pilocarpine hydrochloride ophthalmic solution 0.4% (pilo 0.4%; Qlosi, Orasis Pharmaceuticals) on key performance indicators (KPIs) across seven optometric practice sites within a large, multicenter organization. Eligible subjects were identified opportunistically during routine office visits. All subjects received a written prescription, and all but 3 received a sample/starter kit. Baseline data collection included patient status (new vs established), prior presbyopia management strategy, near add power, optical purchases, new medical diagnoses, and ultra-widefield (UWF) imaging utilization. Patient satisfaction and goal attainment were assessed following a one-week neuroadaptation period. Data were analyzed using descriptive statistics with exact 95% confidence intervals, chi-square testing, and linear mixed models with a random intercept for site; sensitivity to missing satisfaction and goal-attainment data was assessed by multiple imputation and tipping-point analyses.Results

One hundred eleven subjects were enrolled across seven active sites; 34% (32/94 with available data) were new patients. Mean near add power was +1.86D (median +2.00D; range +0.50 to +2.50D). New medical diagnoses were identified in 24.5% of subjects (27/110); optical purchases were recorded in 71.6% (78/109); and UWF imaging was utilized in 85.6% (95/111). Satisfaction data were available for 50 of 111 enrolled subjects (45%); among these, mean satisfaction was 7.32/10 (median 8/10), with 70% rating satisfaction at ≥7; under multiple imputation assuming data missing at random, the estimated mean across all enrolled subjects was 6.49. Goal attainment was reported in 73.1% of users (38/52) with definitive follow-up data. No serious adverse events were reported by participating physicians during the study period. All observed KPI values numerically exceeded their respective historical corporate benchmarks, which served as nonconcurrent comparators; for three of the four KPIs (new patient, new medical diagnosis, and optical purchase rates), the 95% confidence interval included the benchmark value.Conclusion

When implemented within a structured prescribing pathway, pilo 0.4% was not associated with reductions in optical purchasing or ancillary testing utilization during the study period, suggesting feasibility of integration into routine optometric practice. These preliminary, descriptive findings are hypothesis-generating and should be interpreted in the context of the uncontrolled, single-arm pilot design, incomplete follow-up data, and nonconcurrent historical comparators. Controlled studies with larger, more diverse patient populations, prospectively defined outcomes, and longer follow-up periods are needed to establish clinical and economic effectiveness.

Related

  1. Presbyopia, Aging, and Modern Near-Vision Demands: Real-World Functional Outcomes of Pilocarpine-Diclofenac Eye Drops
    Andres F. Zuluaga, Maria A. Montoya-Giraldo, Juliana Leiro +1
    Medicina (Kaunas, Lithuania)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Global Practice Variation and Implementation of Anterior and Anterolateral Thoracic/Thoracolumbar Fracture Surgery: Technical Adoption, Resource Constraints, and Multicenter Readiness.
    Kai-Uwe Lewandrowski, Emmanouil Liodakis, Tobias Fritz +15
    Global spine journalPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMC
  3. Implementation of a Three-Step Cervical Cerclage Technique in Prophylactic and Emergency Settings: Maternal and Perinatal Outcomes in Clinical Practice
    Elena González-Caballero, Lorena Sabonet-Morente, Manuel Gómez-Castellano +4
    Medical sciences (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. Frailty-Informed Assessment in Peritoneal Dialysis: A Multicenter Survey of Current Practice and Implementation Barriers in Spain.
    Estefanya García-Menéndez, Jose Portolés, Luisa Sánchez-García +18
    Geriatrics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  5. Facilitators, Barriers and Reported Implementation Outcomes of Wide‐Awake Local Anaesthesia No Tourniquet in Hand Surgery Practice: A Systematic Scoping Review
    Freya Roberts, Ali Gholamrezaei, Brett McClelland +2
    Anz Journal of SurgeryPeer-reviewedCC BY-NC-ND 4.0Full text1 citedGeneral medicinePMC
BibTeX
@article{chima2026practicelevel,
  title = {{Practice-Level Implementation of 0.4% Pilocarpine for Presbyopia: A Multicenter, Single-Arm Pilot Study of Key Practice Outcomes.}},
  author = {Harmin Chima and John Womack and Katari Campbell and Alan G Kabat},
  journal = {Clinical optometry},
  year = {2026},
  month = nov,
  doi = {10.2147/opto.s642605},
  url = {https://europepmc.org/article/MED/43081147},
  note = {CC BY-NC},
}
RIS
TY  - JOUR
TI  - Practice-Level Implementation of 0.4% Pilocarpine for Presbyopia: A Multicenter, Single-Arm Pilot Study of Key Practice Outcomes.
AU  - Harmin Chima
AU  - John Womack
AU  - Katari Campbell
AU  - Alan G Kabat
PY  - 2026
DA  - 2026/11/20
JO  - Clinical optometry
DO  - 10.2147/opto.s642605
UR  - https://europepmc.org/article/MED/43081147
AB  - Purpose  Despite the growing availability of pharmacologic options for presbyopia management, the practice-level implications of prescribing miotic agents within an optometric setting remain largely unexplored. Practitioners have expressed concern that prescribing these agents might reduce the use or purchase of optical corrective devices, or otherwise disrupt established revenue streams. The Presbyopia Pathway Implementation Pilot was undertaken to address these concerns using real-world, practice-based data.Patients and methods  This multicenter, single-arm, open-label pilot study assessed the impact of pilocarpine hydrochloride ophthalmic solution 0.4% (pilo 0.4%; Qlosi, Orasis Pharmaceuticals) on key performance indicators (KPIs) across seven optometric practice sites within a large, multicenter organization. Eligible subjects were identified opportunistically during routine office visits. All subjects received a written prescription, and all but 3 received a sample/starter kit. Baseline data collection included patient status (new vs established), prior presbyopia management strategy, near add power, optical purchases, new medical diagnoses, and ultra-widefield (UWF) imaging utilization. Patient satisfaction and goal attainment were assessed following a one-week neuroadaptation period. Data were analyzed using descriptive statistics with exact 95% confidence intervals, chi-square testing, and linear mixed models with a random intercept for site; sensitivity to missing satisfaction and goal-attainment data was assessed by multiple imputation and tipping-point analyses.Results  One hundred eleven subjects were enrolled across seven active sites; 34% (32/94 with available data) were new patients. Mean near add power was +1.86D (median +2.00D; range +0.50 to +2.50D). New medical diagnoses were identified in 24.5% of subjects (27/110); optical purchases were recorded in 71.6% (78/109); and UWF imaging was utilized in 85.6% (95/111). Satisfaction data were available for 50 of 111 enrolled subjects (45%); among these, mean satisfaction was 7.32/10 (median 8/10), with 70% rating satisfaction at ≥7; under multiple imputation assuming data missing at random, the estimated mean across all enrolled subjects was 6.49. Goal attainment was reported in 73.1% of users (38/52) with definitive follow-up data. No serious adverse events were reported by participating physicians during the study period. All observed KPI values numerically exceeded their respective historical corporate benchmarks, which served as nonconcurrent comparators; for three of the four KPIs (new patient, new medical diagnosis, and optical purchase rates), the 95% confidence interval included the benchmark value.Conclusion  When implemented within a structured prescribing pathway, pilo 0.4% was not associated with reductions in optical purchasing or ancillary testing utilization during the study period, suggesting feasibility of integration into routine optometric practice. These preliminary, descriptive findings are hypothesis-generating and should be interpreted in the context of the uncontrolled, single-arm pilot design, incomplete follow-up data, and nonconcurrent historical comparators. Controlled studies with larger, more diverse patient populations, prospectively defined outcomes, and longer follow-up periods are needed to establish clinical and economic effectiveness.
SN  - 1179-2752
ER  -