In Vivo K-edge Imaging on a Clinical Dual-source PCCT: Feasibility of Gadolinium Applications in a Porcine Model
- 1University of Pennsylvania
Abstract
ObjectivesTo evaluate the feasibility of in vivo gadolinium K-edge imaging on a clinical dual-source photon-counting CT (PCCT) system in a porcine model and to assess its performance for dynamic contrast-enhanced imaging, functional biliary imaging, and dual-contrast (bi-phasic) imaging.
Materials and MethodsA single healthy Yorkshire-Landrace pig was imaged on a clinical dual-source PCCT system (140 kVp; energy thresholds 20/55/72/90 keV; CTDIvol 12 mGy). Gadolinium K-edge material-specific maps were generated with a calibration- based least-squares material decomposition. Three imaging protocols were evaluated for feasibility: (A) contrast dose testing for dynamic imaging with a hepatobiliary-clearing gadolinium contrast agent (0.2 and 0.8 mL/kg); (B) functional biliary imaging with dynamic and delayed acquisitions; and (C) dual-contrast imaging with simultaneous iodine and gadolinium decomposition. Attenuation (HU) and material concentrations (mg/mL) were measured from regions of interest.
ResultsGadolinium was quantifiable in material-specific maps at a contrast dose of 0.8 mL/kg (arterial aortic signal, 114 {+/-} 4 HU and 1.4 {+/-} 0.3 mg/mL; delayed bile duct, 111 {+/-} 4 HU and 4.3 {+/-} 0.4 mg/mL). Hepatobiliary excretion was tracked over time, with bile duct gadolinium plateauing near 3.3 mg/mL approximately 15 minutes after injection. In the dual-contrast acquisition, arterial gadolinium (2.5 {+/-} 0.7 mg/mL) and portal venous iodine (1.9 {+/-} 0.7 mg/mL) were separated within the liver, and both agents were separated within the ureters.
ConclusionsIn this proof of concept, gadolinium K-edge imaging was feasible on a clinical dual-source PCCT system for dynamic, functional biliary, and dual-contrast applications, supporting further development with improved material-decomposition sensitivity and confirmation in larger studies.
Key PointsO_LIGadolinium K-edge imaging is feasible in vivo on a clinical dual-source photon- counting CT system, producing gadolinium-specific quantitative maps. C_LIO_LIFunctional biliary imaging with gadoxetate disodium tracked hepatobiliary excretion over time, with biliary gadolinium plateauing approximately 15 minutes after injection. C_LIO_LIA dual-contrast acquisition separated gadolinium (arterial phase) from iodine (portal venous phase) within the liver and ureters, enabling simultaneous multi-phase, multi-agent imaging. C_LI
Related
- Choriocapillaris Dysfunction in Retinal Diseases: Multimodal Imaging Biomarkers, Pathophysiological Insights, and Emerging Clinical Applications
- Technical feasibility of synchronized multispectral dual-site optical sensing during vascular occlusion in an acute porcine flap model
- Frequency of late gadolinium enhancement-negative cardiac magnetic resonance imaging at initial presentation with metabolically active treatment-naïve cardiac sarcoidosis.
- Visualization of the Eustachian Tube Cartilage on Delayed Contrast-enhanced 3D-MR Imaging: A Preliminary Comparison between Ionic and Non-ionic Gadolinium-based Contrast Agents
- Mapping the Synaptome in Neurodegeneration: Emerging Clinical Applications of SV2A PET Imaging
BibTeX
@misc{rybertt2026vivo,
title = {{In Vivo K-edge Imaging on a Clinical Dual-source PCCT: Feasibility of Gadolinium Applications in a Porcine Model}},
author = {M. V. Rybertt and L. P. Liu and P. Sahbaee and G. McClung and M. Mathew and P. B. Noël and A. H. Dhanaliwala},
howpublished = {medRxiv},
year = {2026},
month = sep,
doi = {10.64898/2026.09.07.26362472},
url = {https://www.medrxiv.org/content/10.64898/2026.09.07.26362472v1},
note = {CC BY},
}
RIS
TY - UNPB
TI - In Vivo K-edge Imaging on a Clinical Dual-source PCCT: Feasibility of Gadolinium Applications in a Porcine Model
AU - M. V. Rybertt
AU - L. P. Liu
AU - P. Sahbaee
AU - G. McClung
AU - M. Mathew
AU - P. B. Noël
AU - A. H. Dhanaliwala
PY - 2026
DA - 2026/09/07
PB - medRxiv
DO - 10.64898/2026.09.07.26362472
UR - https://www.medrxiv.org/content/10.64898/2026.09.07.26362472v1
AB - ObjectivesTo evaluate the feasibility of in vivo gadolinium K-edge imaging on a clinical dual-source photon-counting CT (PCCT) system in a porcine model and to assess its performance for dynamic contrast-enhanced imaging, functional biliary imaging, and dual-contrast (bi-phasic) imaging. Materials and MethodsA single healthy Yorkshire-Landrace pig was imaged on a clinical dual-source PCCT system (140 kVp; energy thresholds 20/55/72/90 keV; CTDIvol 12 mGy). Gadolinium K-edge material-specific maps were generated with a calibration- based least-squares material decomposition. Three imaging protocols were evaluated for feasibility: (A) contrast dose testing for dynamic imaging with a hepatobiliary-clearing gadolinium contrast agent (0.2 and 0.8 mL/kg); (B) functional biliary imaging with dynamic and delayed acquisitions; and (C) dual-contrast imaging with simultaneous iodine and gadolinium decomposition. Attenuation (HU) and material concentrations (mg/mL) were measured from regions of interest. ResultsGadolinium was quantifiable in material-specific maps at a contrast dose of 0.8 mL/kg (arterial aortic signal, 114 {+/-} 4 HU and 1.4 {+/-} 0.3 mg/mL; delayed bile duct, 111 {+/-} 4 HU and 4.3 {+/-} 0.4 mg/mL). Hepatobiliary excretion was tracked over time, with bile duct gadolinium plateauing near 3.3 mg/mL approximately 15 minutes after injection. In the dual-contrast acquisition, arterial gadolinium (2.5 {+/-} 0.7 mg/mL) and portal venous iodine (1.9 {+/-} 0.7 mg/mL) were separated within the liver, and both agents were separated within the ureters. ConclusionsIn this proof of concept, gadolinium K-edge imaging was feasible on a clinical dual-source PCCT system for dynamic, functional biliary, and dual-contrast applications, supporting further development with improved material-decomposition sensitivity and confirmation in larger studies. Key PointsO_LIGadolinium K-edge imaging is feasible in vivo on a clinical dual-source photon- counting CT system, producing gadolinium-specific quantitative maps. C_LIO_LIFunctional biliary imaging with gadoxetate disodium tracked hepatobiliary excretion over time, with biliary gadolinium plateauing approximately 15 minutes after injection. C_LIO_LIA dual-contrast acquisition separated gadolinium (arterial phase) from iodine (portal venous phase) within the liver and ureters, enabling simultaneous multi-phase, multi-agent imaging. C_LI
ER -