Skip to content
DraconiticResearch
Search Sources API
203,952 studies31 sourcesUpdated 18 min ago
Peer-reviewedCC BY-NC-SADental research journal

Comparison of bond strength in fixed multistrand retainers using universal and conventional adhesives: An in vitro study.

  1. 1Department of Orthodontics, Dental Research Center, School of Dentistry, Dental Research Institute, Isfahan University of Medical Sciences, Tehran, Iran.
  2. 2Department of Prosthodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran.
  3. 3Department of Operative Dentistry, Dental Materials Research Center, Dental Research Institute, Isfahan University of Medical Sciences, Isfahan, Iran.

Abstract

Background

To prevent relapses, fixed retainers are used. However, bond failure is a common issue. This study compares shear bond strength and failure mode using conventional and universal adhesives (UAs), containing 10-MDP, with different application methods.Materials and methods

In this in vitro study, 120 intact maxillary premolars were divided into four groups and treated with a UA or a conventional adhesive (CA) with or without a primer application on wire. The teeth were assessed using a 0.0195" three-strand multistrand wire and a high-filler flowable composite. Bond strength was measured after thermocycling, and the adhesive remnant index (ARI) was determined for all samples. An independent t-test was used to compare the means of quantitative variables, and a Chi-square test was used to compare the distribution of qualitative data (P < 0.05).Results

The mean bond strength for the group where the primer was applied to the wire surface with UA was 33.28 Newton (N), and with CA, it was 37.17 N. The mean bond strength of the samples without primer application on the wire surface with UA and CA was 40.88 N and 38.42 N, respectively, despite no statistically significant differences between the groups (P > 0.05). There was no significant difference in ARI between the groups with and without primer application on the wire surface.Conclusion

The application or nonapplication of primer on the wire surface and the type of adhesive had no significant effect on the bond strength and ARI of the samples.

Related

  1. Influence of Universal Adhesives With or Without Silane Compared to One‐Step and Two‐Step Silane Agents on Bond Strength to Lithium Disilicate
    Camilo Pulido, Michel Wendlinger, Gabriel David Cochinski +2
    Journal of Esthetic and Restorative DentistryPeer-reviewedCC BY 4.0Full textPMC
  2. Effect of chemical surface pretreatments on microtensile bond strength of resin composite to dentin when using universal adhesives: a systematic review of laboratory studies.
    Ereny Isaac, Safaa Helmy Abd-Elhakim, Hamdi H Hamama +1
    BDJ openPeer-reviewedCC BYFull textGeneral medicineEurope PMCDOAJ
  3. In Vivo Comparison of the Trueness of Conventional and Digital Interocclusal Registration
    Bioengineering (Basel, Switzerland)Peer-reviewedCC BYFull textEurope PMC
  4. Comparison of Hockey-Stick and Conventional Linear Ultrasound Transducers for Detection of Non-Displaced Dentoalveolar Fractures: An Ex Vivo Paired Comparative Study
    Murat Mert Atapek, Sedef Ayşe Taşyapan, Elif Yıldızer
    TomographyPeer-reviewedCC BYFull textMedical imaging & radiologyEurope PMC
  5. Conventional Ion-Exchange and Chelating Resins for Metal Recovery: A Critical Comparison of Selectivity, Dynamic Performance, Regeneration, and Process Integration
    Antonio Clareti Pereira,, PhD
    International Journal of Current Science Research and ReviewPeer-reviewedLicence not stated7 citedMaterials & polymersOpenAlex
BibTeX
@article{zarei2026comparison,
  title = {{Comparison of bond strength in fixed multistrand retainers using universal and conventional adhesives: An in vitro study.}},
  author = {Zahra Zarei and Mahdi Zahedi and Atiyeh Feiz},
  journal = {Dental research journal},
  year = {2026},
  month = oct,
  doi = {10.4103/drj.drj_498_24},
  url = {https://europepmc.org/article/MED/42974578},
  note = {CC BY-NC-SA},
}
RIS
TY  - JOUR
TI  - Comparison of bond strength in fixed multistrand retainers using universal and conventional adhesives: An in vitro study.
AU  - Zahra Zarei
AU  - Mahdi Zahedi
AU  - Atiyeh Feiz
PY  - 2026
DA  - 2026/10/08
JO  - Dental research journal
DO  - 10.4103/drj.drj_498_24
UR  - https://europepmc.org/article/MED/42974578
AB  - Background  To prevent relapses, fixed retainers are used. However, bond failure is a common issue. This study compares shear bond strength and failure mode using conventional and universal adhesives (UAs), containing 10-MDP, with different application methods.Materials and methods  In this in vitro study, 120 intact maxillary premolars were divided into four groups and treated with a UA or a conventional adhesive (CA) with or without a primer application on wire. The teeth were assessed using a 0.0195" three-strand multistrand wire and a high-filler flowable composite. Bond strength was measured after thermocycling, and the adhesive remnant index (ARI) was determined for all samples. An independent t-test was used to compare the means of quantitative variables, and a Chi-square test was used to compare the distribution of qualitative data (P < 0.05).Results  The mean bond strength for the group where the primer was applied to the wire surface with UA was 33.28 Newton (N), and with CA, it was 37.17 N. The mean bond strength of the samples without primer application on the wire surface with UA and CA was 40.88 N and 38.42 N, respectively, despite no statistically significant differences between the groups (P > 0.05). There was no significant difference in ARI between the groups with and without primer application on the wire surface.Conclusion  The application or nonapplication of primer on the wire surface and the type of adhesive had no significant effect on the bond strength and ARI of the samples.
SN  - 1735-3327
SN  - 2008-0255
ER  -