Skip to content
DraconiticResearch
Search Sources API
190,851 studies31 sourcesUpdated 18 min ago
PreprintCC BYChemRxiv

PolycIMS: Polymers for Automated Cyclic Ion Mobility Spectrometry Calibration

  1. 1Organic Synthesis and Mass Spectrometry Laboratory, University of Mons, Place du Parc 23, Mons, Belgium, 7000
  2. 2Institut Lumière-Matière
  3. 3Université Claude Bernard Lyon

Abstract

The development and commercialization of cyclic ion mobility spectrometry (cIMS) instruments has considerably expanded the level of structural details that can be accessed for gaseous ions. Commercial cIMS instruments rely on travelling wave ion mobility spectrometry (TWIMS), a technique that requires calibration of the measured arrival times to enable the determination of collisional cross sections (CCS). Most calibration strategies use peptide mixtures that span a CCS range of approximately 100 – 400 Å2, which can introduce significant inaccuracies when extrapolating to larger ion structures. In addition, TWIMS calibration remains a tedious data processing step that would greatly benefit from automation. Here, we introduce polycIMS, a command-line tool that automates cIMS calibration and generates charge-independent calibration curves covering a broad CCS range from 100 – 1500 Ų, within just 3 minutes on a standard laptop. Calibrated CCS can be determined in He or N 2 ( TW CCS N2→He , TW CCS N2→N2 ) using inexpensive, commercially-available polymer standards and are validated against reported values for more than 50 reference ions. Furthermore, the derived calibration parameters are largely insensitive to collisional activation, making it possible to calibrate multistage cIMS workflows such as slice collision induced unfolding (CIU n ). We anticipate that the simplicity and accessibility of polycIMS will encourage its adoption as a new standard for cIMS calibration.

Related

  1. Automated Full-Spectrum Multivariate Calibration for Quantitative Glow Discharge Optical Emission Spectrometry
    Marius R. Bittermann, Beatrice Battistella, Volker Hoffmann +4
    ChemRxivPreprintLicence not statedGeneral chemistryChemRxiv
  2. Integrating Ion Mobility–Resolved Tandem Mass Spectrometry and Microcrystal Electron Diffraction for Structural Elucidation
    Aleyna Lumsden, Amalia-Sofia Piticari, Amar Rai +12
    ChemRxivPreprintLicence not statedGeneral chemistryChemRxiv
  3. Rapid chromatography combined with trapped ion mobility mass spectrometry for analysis of derivatized small molecules
    Matthias Anagho-Mattanovich, Ondrej Hodek, Aiko Barsch +8
    ChemRxivPreprintCC BYFull textPhysical chemistryChemRxiv
  4. Precision Profiling of α‐1,4‐ Versus α‐1,6‐Glycosidase Activity Through Synthetic Linear and Branched Glycogen Tetramers Using Cyclic Ion Mobility Mass Spectrometry and High‐Performance Liquid Chromatography‐Mass Spectrometry
    Delphine Carry, Ruben Ananian, Zineb Chaabi +10
    ChemistryEuropePeer-reviewedCC BY 4.0Full textOrganic chemistryHAL
  5. Conformational Dynamics of Cation-Cryptophane Complexes by Ion Mobility Mass Spectrometry
    Oscar H. Lloyd Williams, Niklas Geue, Thomas D. Hoare +9
    ChemRxivPreprintCC BYFull textPhysical chemistryChemRxiv
BibTeX
@misc{duez2026polycims,
  title = {{PolycIMS: Polymers for Automated Cyclic Ion Mobility Spectrometry Calibration}},
  author = {Quentin Duez and Louis Groignet and Thomas Robert and Fabien Chirot and Pascal Gerbaux and Julien De Winter},
  howpublished = {ChemRxiv},
  year = {2026},
  month = oct,
  doi = {10.26434/chemrxiv.15002305/v2},
  url = {https://chemrxiv.org/doi/full/10.26434/chemrxiv.15002305/v2},
  note = {CC BY},
}
RIS
TY  - UNPB
TI  - PolycIMS: Polymers for Automated Cyclic Ion Mobility Spectrometry Calibration
AU  - Quentin Duez
AU  - Louis Groignet
AU  - Thomas Robert
AU  - Fabien Chirot
AU  - Pascal Gerbaux
AU  - Julien De Winter
PY  - 2026
DA  - 2026/10/12
PB  - ChemRxiv
DO  - 10.26434/chemrxiv.15002305/v2
UR  - https://chemrxiv.org/doi/full/10.26434/chemrxiv.15002305/v2
AB  - The development and commercialization of cyclic ion mobility spectrometry (cIMS) instruments has considerably expanded the level of structural details that can be accessed for gaseous ions. Commercial cIMS instruments rely on travelling wave ion mobility spectrometry (TWIMS), a technique that requires calibration of the measured arrival times to enable the determination of collisional cross sections (CCS). Most calibration strategies use peptide mixtures that span a CCS range of approximately 100 – 400 Å2, which can introduce significant inaccuracies when extrapolating to larger ion structures. In addition, TWIMS calibration remains a tedious data processing step that would greatly benefit from automation. Here, we introduce polycIMS, a command-line tool that automates cIMS calibration and generates charge-independent calibration curves covering a broad CCS range from 100 – 1500 Ų, within just 3 minutes on a standard laptop. Calibrated CCS can be determined in He or N 2 ( TW CCS N2→He , TW CCS N2→N2 ) using inexpensive, commercially-available polymer standards and are validated against reported values for more than 50 reference ions. Furthermore, the derived calibration parameters are largely insensitive to collisional activation, making it possible to calibrate multistage cIMS workflows such as slice collision induced unfolding (CIU n ). We anticipate that the simplicity and accessibility of polycIMS will encourage its adoption as a new standard for cIMS calibration.
ER  -