Abstract
Introduction: Incision-related Descemet membrane detachment (DMD) can arise at different stages of cataract surgery, but its real-time intraoperative characteristics and associated factors remain incompletely understood. This study aimed to characterize incision-related DMD in 2.65 mm clear corneal incisions and to identify factors associated with its occurrence using intraoperative optical coherence tomography (iOCT).
Methods: A total of 179 patients (179 eyes) with cataracts underwent coaxial 2.65 mm clear corneal incision phacoemulsification with intraocular lens implantation. iOCT was used for real-time scanning of the corneal main incision, recording DMD occurrence and extent at each procedural step. The full cohort was used for descriptive analyses and to evaluate associations between baseline factors and DMD detected at any intraoperative stage. Irrigation/aspiration (I/A)-related exposures were evaluated in the primary I/A analysis cohort, comprising the 145 eyes that remained DMD-free at I/A initiation. The primary outcome was newly detected DMD, defined as the first detection of DMD during I/A or at any subsequent intraoperative stage. A new parameter, I/A incision-deformation time, was defined as the cumulative duration of instrument–incision engagement accompanied by visible incision deformation during the I/A stage.
Results: Intraoperative DMD was detected in 109 of 179 eyes (60.9%) and was first observed most frequently during I/A (43.1%). In the primary I/A analysis cohort (n = 145), longer I/A incision-deformation time (adjusted odds ratio [aOR] = 1.23; 95% CI, 1.12–1.36; P < 0.001) and greater nuclear hardness (aOR = 4.20; 95% CI, 2.08–8.50; P < 0.001) were independently associated with the occurrence of DMD. I/A incision-deformation time and nuclear hardness showed similar discrimination (area under the curve [AUC], 0.728 and 0.726, respectively), while their exploratory combination yielded an optimism-corrected AUC of 0.800.
Conclusions: Longer I/A incision-deformation time and greater nuclear hardness were independently associated with DMD occurrence. I/A incision-deformation time may offer a reproducible quantitative measure of instrument–incision interactions during cataract surgery.
Trial registration: ChiCTR2100042379.
Related
- Intraoperative OCT observation of incision-related descemet membrane detachment during implantable collamer lens implantation.
- Ripple-Like Descemet Membrane Folds Following Combined Microhook Ab Interno Trabeculotomy and Cataract Surgery: A Case Report
- Preloaded Descemet membrane endothelial keratoplasty: meta-analysis of the eye bank prepared grafts transplanted in the last decade
- Multi-scale analysis of histological, ultrastructural and proteomic regional differences in the Descemet’s membrane-endothelium of Fuchs endothelial corneal dystrophy
- Acellular Bowman Layer and Descemet Membrane Allografts for Non-Ectatic Anterior Corneal Diseases: A Narrative Review of Emerging Evidence
BibTeX
@article{guo2026characteristics,
title = {{Characteristics and Factors of Incision-Related Descemet Membrane Detachment During Cataract Surgery: A Prospective Study}},
author = {Wenfei Guo and Ranyi Ding and Can Zhao and Xiaofeng Li and Xi Lu and Xiaowei Zhong and Weiyun Shi and Jijun Sun and Ting Wang},
journal = {Ophthalmology and Therapy},
year = {2026},
month = oct,
doi = {10.1007/s40123-026-01519-6},
url = {https://doi.org/10.1007/s40123-026-01519-6},
note = {CC BY-NC 4.0},
}
RIS
TY - JOUR
TI - Characteristics and Factors of Incision-Related Descemet Membrane Detachment During Cataract Surgery: A Prospective Study
AU - Wenfei Guo
AU - Ranyi Ding
AU - Can Zhao
AU - Xiaofeng Li
AU - Xi Lu
AU - Xiaowei Zhong
AU - Weiyun Shi
AU - Jijun Sun
AU - Ting Wang
PY - 2026
DA - 2026/10/09
JO - Ophthalmology and Therapy
DO - 10.1007/s40123-026-01519-6
UR - https://doi.org/10.1007/s40123-026-01519-6
AB - Introduction: Incision-related Descemet membrane detachment (DMD) can arise at different stages of cataract surgery, but its real-time intraoperative characteristics and associated factors remain incompletely understood. This study aimed to characterize incision-related DMD in 2.65 mm clear corneal incisions and to identify factors associated with its occurrence using intraoperative optical coherence tomography (iOCT). Methods: A total of 179 patients (179 eyes) with cataracts underwent coaxial 2.65 mm clear corneal incision phacoemulsification with intraocular lens implantation. iOCT was used for real-time scanning of the corneal main incision, recording DMD occurrence and extent at each procedural step. The full cohort was used for descriptive analyses and to evaluate associations between baseline factors and DMD detected at any intraoperative stage. Irrigation/aspiration (I/A)-related exposures were evaluated in the primary I/A analysis cohort, comprising the 145 eyes that remained DMD-free at I/A initiation. The primary outcome was newly detected DMD, defined as the first detection of DMD during I/A or at any subsequent intraoperative stage. A new parameter, I/A incision-deformation time, was defined as the cumulative duration of instrument–incision engagement accompanied by visible incision deformation during the I/A stage. Results: Intraoperative DMD was detected in 109 of 179 eyes (60.9%) and was first observed most frequently during I/A (43.1%). In the primary I/A analysis cohort (n = 145), longer I/A incision-deformation time (adjusted odds ratio [aOR] = 1.23; 95% CI, 1.12–1.36; P < 0.001) and greater nuclear hardness (aOR = 4.20; 95% CI, 2.08–8.50; P < 0.001) were independently associated with the occurrence of DMD. I/A incision-deformation time and nuclear hardness showed similar discrimination (area under the curve [AUC], 0.728 and 0.726, respectively), while their exploratory combination yielded an optimism-corrected AUC of 0.800. Conclusions: Longer I/A incision-deformation time and greater nuclear hardness were independently associated with DMD occurrence. I/A incision-deformation time may offer a reproducible quantitative measure of instrument–incision interactions during cataract surgery. Trial registration: ChiCTR2100042379.
SN - 2193-8245
SN - 2193-6528
ER -