Skip to content
DraconiticResearch
Search Sources API
201,683 studies31 sourcesUpdated 40 min ago
Peer-reviewedCC BY-NC 4.0The Journal of International Medical Research

Development and internal validation of a risk-scoring model for gastrointestinal flexible endoscope reprocessing failure: A retrospective observational study

  1. 1Department of Nursing, The Second Affiliated Hospital of Zhejiang University School of Medicine, China
  2. 2Department of Cardiology, The Second Affiliated Hospital of Zhejiang University School of Medicine, China

Abstract

Objective: To identify risk factors for flexible gastrointestinal endoscope reprocessing failure and develop a practical risk-scoring model for the early identification of high-risk reprocessing cycles.

Methods: This retrospective observational study, conducted from January to December 2025 at three endoscopy centers, included 2744 reprocessing cycles that adhered to WS 507-2016. Internal validation was performed using a split-sample approach, with 70% of the sample used for model derivation and 30% for validation. Predictors were selected using univariable and multivariable logistic regression and converted into an integer-based scoring system, with the optimal cutoff determined using the Youden index. Reporting followed the Transparent Reporting of a Multivariable Prediction Model for Individual Prognosis or Diagnosis and Strengthening the Reporting of Observational Studies in Epidemiology guidelines, and the study was conducted in accordance with the Declaration of Helsinki.

Results: Among the 2744 eligible reprocessing cycles, 682 (24.85%) exhibited reprocessing failure. Six independent predictors were identified: brushing personnel, washer–disinfector type, accessory use frequency, prior repair history, time from removal to reprocessing, and staff age. The scoring system, with a range of −2 to 18, achieved an area under the curve of 0.834 (95% confidence interval: 0.804–0.864) in the validation cohort. At a cutoff of ≥10, sensitivity was 0.725, specificity was 0.808, positive predictive value was 0.554, and negative predictive value was 0.899. Calibration was satisfactory based on the Hosmer–Lemeshow test and bootstrap analysis.

Conclusions: The internally validated scoring system enables the early identification of high-risk reprocessing cycles and may support quality improvement efforts. However, external validation is needed to assess its generalizability.

Related

  1. Development and internal validation of a simple risk stratification score for unplanned emergency department revisits within 24 hours after discharge: A retrospective observational study
    Hidetaka Onda, Yuma Kuramatsu, Toyoaki Yamamoto +8
    PLOS OnePeer-reviewedCC BY 4.0Full textCell biologyImmunologyPLOS
  2. Microbiological surveillance after automated reprocessing of gastrointestinal endoscopes in routine clinical practice: A prospective randomized microbiological surveillance study
    Masayuki Kato, Hideki Hayashi, Nobuharu Hironaka +6
    PLOS OnePeer-reviewedCC BY 4.0Full textMicrobiologyEpidemiology & public healthPLOS
  3. Development and Content Validation of The Health Promoting Sports Club Observational Tool
    Stacey Johnson, Petra Ozbolt, Louana Friche +6
    Health Promotion PerspectivesPeer-reviewedCC BYGeneral biologyEpidemiology & public healthHAL
  4. Development and Internal Validation of a Nomogram for Predicting Severe Complications After Snakebite: A Retrospective Cohort Study.
    Jiahao Guan, Zhenkai Zhao, Fei Wang +7
    International journal of general medicinePeer-reviewedCC BY-NCFull textGenetics & genomicsEurope PMC
  5. Development and internal validation of prediction models for ICU-level intervention and 14-day mortality at Medical Emergency Team activation: A retrospective cohort study
    Junji Shimauchi, Takuya Nishino, Kenta Shigeta +4
    PLOS OnePeer-reviewedCC BY 4.0Full textCell biologyImmunologyPLOS
BibTeX
@article{fang2026development,
  title = {{Development and internal validation of a risk-scoring model for gastrointestinal flexible endoscope reprocessing failure: A retrospective observational study}},
  author = {Liangyu Fang and Xiaoxuan Zhou and Meifeng Wu and Yinchuan Xu},
  journal = {The Journal of International Medical Research},
  year = {2026},
  month = sep,
  doi = {10.1177/03000605261491484},
  url = {https://doi.org/10.1177/03000605261491484},
  note = {CC BY-NC 4.0},
}
RIS
TY  - JOUR
TI  - Development and internal validation of a risk-scoring model for gastrointestinal flexible endoscope reprocessing failure: A retrospective observational study
AU  - Liangyu Fang
AU  - Xiaoxuan Zhou
AU  - Meifeng Wu
AU  - Yinchuan Xu
PY  - 2026
DA  - 2026/09/28
JO  - The Journal of International Medical Research
DO  - 10.1177/03000605261491484
UR  - https://doi.org/10.1177/03000605261491484
AB  - Objective: To identify risk factors for flexible gastrointestinal endoscope reprocessing failure and develop a practical risk-scoring model for the early identification of high-risk reprocessing cycles.  Methods: This retrospective observational study, conducted from January to December 2025 at three endoscopy centers, included 2744 reprocessing cycles that adhered to WS 507-2016. Internal validation was performed using a split-sample approach, with 70% of the sample used for model derivation and 30% for validation. Predictors were selected using univariable and multivariable logistic regression and converted into an integer-based scoring system, with the optimal cutoff determined using the Youden index. Reporting followed the Transparent Reporting of a Multivariable Prediction Model for Individual Prognosis or Diagnosis and Strengthening the Reporting of Observational Studies in Epidemiology guidelines, and the study was conducted in accordance with the Declaration of Helsinki.  Results: Among the 2744 eligible reprocessing cycles, 682 (24.85%) exhibited reprocessing failure. Six independent predictors were identified: brushing personnel, washer–disinfector type, accessory use frequency, prior repair history, time from removal to reprocessing, and staff age. The scoring system, with a range of −2 to 18, achieved an area under the curve of 0.834 (95% confidence interval: 0.804–0.864) in the validation cohort. At a cutoff of ≥10, sensitivity was 0.725, specificity was 0.808, positive predictive value was 0.554, and negative predictive value was 0.899. Calibration was satisfactory based on the Hosmer–Lemeshow test and bootstrap analysis.  Conclusions: The internally validated scoring system enables the early identification of high-risk reprocessing cycles and may support quality improvement efforts. However, external validation is needed to assess its generalizability.
SN  - 0300-0605
SN  - 1473-2300
ER  -