Impact of stylet-driven lead for left bundle branch area pacing on tricuspid valve function: A comparative analysis with conventional CRT
4 affiliations
- 1Department of Electrophysiology, Heart- and Diabetescenter NRW, Ruhr-University Bochum, Bad Oeynhausen, Germany
- 2Department of General and Interventional Cardiology/Angiology, Heart- and Diabetescenter NRW, Ruhr-University Bochum, Bad Oeynhausen, Germany
- 3Clinic for Cardiac Surgery, Heart- and Diabetescenter NRW, Ruhr-University Bochum, Bad Oeynhausen, Germany
- 4Department of Rhythmology, University Hospital Ruppin-Brandenburg, Brandenburg Medical School Theodor Fontane, Neuruppin, Germany
Abstract
Background: Cardiac implantable electronic devices (CIED) have been associated with an increased incidence of tricuspid regurgitation (TR) due to several factors.
Methods: We examined the outcomes of patients who underwent left bundle brunch area pacing (LBBAP) with stylet-driven leads and compared them with a 1:1 matched historical cohort of patients treated with conventional cardiac resynchronization therapy (CRT).
Results: This retrospective analysis included a total of 396 patients, of whom 132 underwent LBBAP and 264 underwent CRT. After propensity score matching, 95 patients were included in each group. Baseline tricuspid regurgitation severity and left ventricular ejection fraction were also similar. However, diabetes mellitus was more prevalent in the CRT group (47.4% vs. 30.5%, p = 0.02). At follow-up, rates of TR improvement and worsening were low and comparable between LBBAP and CRT. Left ventricular ejection fraction (LVEF) at follow-up was numerically higher in the LBBAP group, while the proportion of patients achieving ≥ 5% LVEF improvement was identical in both groups (41%). Within the LBBAP cohort, TR worsening occurred predominantly in patients with two trans-tricuspid leads and was numerically more frequent in ICD recipients. A shorter annulus-to-lead distance was associated with a trend toward greater TR progression.
Conclusion: No significant differences in TR severity were observed between the LBBAP and conventional CRT groups. In the LBBAP cohort, TR progression was more common in patients with multiple leads traversing the tricuspid valve and a shorter tricuspid annulus–LBBAP lead distance. Due to the limited statistical power of the study, these observations should be considered hypothesis-generating.
Graphical abstract:
Related
- Prognostic Value of Right Ventricular–Pulmonary Artery Coupling in Mitral Valve Surgery and Impact of Concomitant Tricuspid Valve Repair
- Impact of atrial fibrillation catheter ablation o'n tricuspid regurgitation severity: a systematic review and meta-analysis.
- Impact of Tricuspid Regurgitation on Outcomes After Transcatheter Edge-to-Edge Repair for Primary Mitral Regurgitation: The PRIME-MR Registry
- Effects of Transcatheter Tricuspid Edge‐to‐Edge Repair on Right Heart Dimension and Function
- Temporal changes in dilated ascending aorta after transfemoral TAVR: a comparative analysis of bicuspid and tricuspid aortic valves
BibTeX
@article{bocchini2026impact,
title = {{Impact of stylet-driven lead for left bundle branch area pacing on tricuspid valve function: A comparative analysis with conventional CRT}},
author = {Y. Bocchini and H. Omran and T. Eitz and T. Fink and V. Sciacca and M. Didenko and K. Harutyunyan and E. Waezsada and P. Lucas and N. Trajkovska and J. Feld and M. Khalaph and E. Akkaya and C. Niehaus and M. Ivannikova and K. P. Friedrichs and A. Goncharov and F. Rudolph and M. Gerçek and A. Darma and D. Guckel and V. Rudolph and P. Sommer and Guram Imnadze},
journal = {Journal of Interventional Cardiac Electrophysiology},
year = {2026},
month = jul,
doi = {10.1007/s10840-026-02399-3},
url = {https://doi.org/10.1007/s10840-026-02399-3},
note = {CC BY-NC-ND 4.0},
}
RIS
TY - JOUR
TI - Impact of stylet-driven lead for left bundle branch area pacing on tricuspid valve function: A comparative analysis with conventional CRT
AU - Y. Bocchini
AU - H. Omran
AU - T. Eitz
AU - T. Fink
AU - V. Sciacca
AU - M. Didenko
AU - K. Harutyunyan
AU - E. Waezsada
AU - P. Lucas
AU - N. Trajkovska
AU - J. Feld
AU - M. Khalaph
AU - E. Akkaya
AU - C. Niehaus
AU - M. Ivannikova
AU - K. P. Friedrichs
AU - A. Goncharov
AU - F. Rudolph
AU - M. Gerçek
AU - A. Darma
AU - D. Guckel
AU - V. Rudolph
AU - P. Sommer
AU - Guram Imnadze
PY - 2026
DA - 2026/07/23
JO - Journal of Interventional Cardiac Electrophysiology
DO - 10.1007/s10840-026-02399-3
UR - https://doi.org/10.1007/s10840-026-02399-3
AB - Background: Cardiac implantable electronic devices (CIED) have been associated with an increased incidence of tricuspid regurgitation (TR) due to several factors. Methods: We examined the outcomes of patients who underwent left bundle brunch area pacing (LBBAP) with stylet-driven leads and compared them with a 1:1 matched historical cohort of patients treated with conventional cardiac resynchronization therapy (CRT). Results: This retrospective analysis included a total of 396 patients, of whom 132 underwent LBBAP and 264 underwent CRT. After propensity score matching, 95 patients were included in each group. Baseline tricuspid regurgitation severity and left ventricular ejection fraction were also similar. However, diabetes mellitus was more prevalent in the CRT group (47.4% vs. 30.5%, p = 0.02). At follow-up, rates of TR improvement and worsening were low and comparable between LBBAP and CRT. Left ventricular ejection fraction (LVEF) at follow-up was numerically higher in the LBBAP group, while the proportion of patients achieving ≥ 5% LVEF improvement was identical in both groups (41%). Within the LBBAP cohort, TR worsening occurred predominantly in patients with two trans-tricuspid leads and was numerically more frequent in ICD recipients. A shorter annulus-to-lead distance was associated with a trend toward greater TR progression. Conclusion: No significant differences in TR severity were observed between the LBBAP and conventional CRT groups. In the LBBAP cohort, TR progression was more common in patients with multiple leads traversing the tricuspid valve and a shorter tricuspid annulus–LBBAP lead distance. Due to the limited statistical power of the study, these observations should be considered hypothesis-generating. Graphical abstract:
SN - 1383-875X
SN - 1572-8595
ER -