Skip to content
DraconiticResearch
Search Sources API
203,948 studies31 sourcesUpdated 51 min ago
Peer-reviewedCC BY 4.0Journal of Clinical Medicine

Effect of Intrapulmonary Gas Composition on Lung Ultrasound A-Line Artifacts and Grayscale Intensity: A Prospective Exploratory Study with Heliox in Healthy Volunteers

  1. 1Department of Pulmonology, Wojewódzkie Centrum Szpitalne Kotliny Jeleniogórskiej, Ogińskiego 6, 58-506 Jelenia Góra, Poland
  2. 2Clinical Ultrasound Laboratory, Medical Simulation Center, Medical University of Gdańsk, Dębinki 7, 80-211 Gdańsk, Poland
  3. 3Faculty of Medicine, Medical University of Gdańsk, Dębinki 7, 80-211 Gdańsk, Poland

Abstract

Background/Objectives: Lung ultrasound (LUS) of the aerated lung relies on artifacts generated at the pleural interface, but the contribution of intrapulmonary gas to these artifacts has not been studied in humans. Heliox, a helium–oxygen mixture with low density and acoustic impedance, allows the gas phase of the lung to be modified without altering its structure. We examined whether heliox breathing alters A-line artifacts and grayscale intensity in LUS images. Methods: In this prospective exploratory study, 52 healthy volunteers underwent LUS at four thoracic locations during ambient-air breathing and subsequently during heliox (80% He/20% O2) breathing. A-lines were counted manually, and grayscale intensity and horizontal reverberations were quantified in ImageJ. Paired differences were analyzed with a clustered Wilcoxon signed-rank test and cluster-bootstrap 95% confidence intervals (CIs). Reliability of A-line counting was assessed in a stratified random subsample (13 participants, 104 images) by blinded test–retest and inter-observer re-counting. Results: Heliox breathing increased global grayscale intensity (mean difference 6.7 grayscale units, 95% CI 4.1–9.2; p < 0.001), most markedly in the deepest image compartment (10.1 units, 95% CI 6.5–13.9), and the number of visible A-lines (0.45, 95% CI 0.30–0.62; p < 0.001). Horizontal reverberations did not differ. In the blinded subsample, the heliox–air difference in A-lines decreased from 0.44 in the original unblinded count to 0.21 in the blinded test–retest and 0.04 in the second reader’s count, and the 95% limits of agreement for manual counting (approximately ±1.2 A-lines per image) exceeded the prespecified minimum relevant difference of one A-line. Conclusions: Heliox breathing was associated with a consistent, depth-dependent increase in the grayscale intensity of lung ultrasound images, suggesting that intrapulmonary gas composition contributes to image brightness. The concomitant change in A-line counts was directionally consistent but smaller than the resolution of manual counting at the imaging depth used and therefore remains inconclusive.

Related

  1. 5T Non-Contrast One-Stop MRA for Thoracic Aorta and Coronary Arteries: A Prospective Feasibility Study in Healthy Volunteers
    Yan Xu, Chuangwei Wei, Runzhi Zhang +7
    Journal of cardiovascular development and diseasePeer-reviewedCC BYFull textCardiovascular medicineEurope PMC
  2. Association between body composition and calcaneal ultrasound t-score in middle-aged and older adults from four ethnic minorities in Guangxi, China
    Xiquan Wang, Aojie Chen, Hongrong Yu
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textSurgery & anaesthesiaCrossref
  3. Real-Time AI-Based ACR TI-RADS Classification of Thyroid Nodules on the Ultrasound Console: A Prospective Agreement Study in a Region with Historical Iodine Deficiency
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. Microfocused ultrasound for facial and neck rejuvenation : A pilot prospective observational study on efficacy and safety in patients with skin laxity
    Zhonglan Pan, Yanqiu Tang, Sihui Wang +2
    MedicinePeer-reviewedCC BY-NCFull textGeneral medicineEurope PMC
  5. Second‐line MRI after expert transvaginal ultrasound in selected patients with suspected complex deep endometriosis: A prospective cohort study
    Mira Rehal, Malin Brunes, Chikako Suzuki +1
    Acta obstetricia et gynecologica ScandinavicaPeer-reviewedCC BYFull textGeneral medicineEurope PMC
BibTeX
@article{leciejewska2026effect,
  title = {{Effect of Intrapulmonary Gas Composition on Lung Ultrasound A-Line Artifacts and Grayscale Intensity: A Prospective Exploratory Study with Heliox in Healthy Volunteers}},
  author = {Małgorzata Leciejewska and Natalia Buda and Mateusz Pawłowski},
  journal = {Journal of Clinical Medicine},
  year = {2026},
  month = nov,
  doi = {10.3390/jcm15218723},
  url = {https://www.mdpi.com/2077-0383/15/21/8723},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Effect of Intrapulmonary Gas Composition on Lung Ultrasound A-Line Artifacts and Grayscale Intensity: A Prospective Exploratory Study with Heliox in Healthy Volunteers
AU  - Małgorzata Leciejewska
AU  - Natalia Buda
AU  - Mateusz Pawłowski
PY  - 2026
DA  - 2026/11/08
JO  - Journal of Clinical Medicine
DO  - 10.3390/jcm15218723
UR  - https://www.mdpi.com/2077-0383/15/21/8723
AB  - Background/Objectives: Lung ultrasound (LUS) of the aerated lung relies on artifacts generated at the pleural interface, but the contribution of intrapulmonary gas to these artifacts has not been studied in humans. Heliox, a helium–oxygen mixture with low density and acoustic impedance, allows the gas phase of the lung to be modified without altering its structure. We examined whether heliox breathing alters A-line artifacts and grayscale intensity in LUS images. Methods: In this prospective exploratory study, 52 healthy volunteers underwent LUS at four thoracic locations during ambient-air breathing and subsequently during heliox (80% He/20% O2) breathing. A-lines were counted manually, and grayscale intensity and horizontal reverberations were quantified in ImageJ. Paired differences were analyzed with a clustered Wilcoxon signed-rank test and cluster-bootstrap 95% confidence intervals (CIs). Reliability of A-line counting was assessed in a stratified random subsample (13 participants, 104 images) by blinded test–retest and inter-observer re-counting. Results: Heliox breathing increased global grayscale intensity (mean difference 6.7 grayscale units, 95% CI 4.1–9.2; p < 0.001), most markedly in the deepest image compartment (10.1 units, 95% CI 6.5–13.9), and the number of visible A-lines (0.45, 95% CI 0.30–0.62; p < 0.001). Horizontal reverberations did not differ. In the blinded subsample, the heliox–air difference in A-lines decreased from 0.44 in the original unblinded count to 0.21 in the blinded test–retest and 0.04 in the second reader’s count, and the 95% limits of agreement for manual counting (approximately ±1.2 A-lines per image) exceeded the prespecified minimum relevant difference of one A-line. Conclusions: Heliox breathing was associated with a consistent, depth-dependent increase in the grayscale intensity of lung ultrasound images, suggesting that intrapulmonary gas composition contributes to image brightness. The concomitant change in A-line counts was directionally consistent but smaller than the resolution of manual counting at the imaging depth used and therefore remains inconclusive.
SN  - 2077-0383
ER  -