Refractive Surprise following Cataract Surgery in a Patient with a Prior Decentered Myopic Ablation: A Case Report
- 1Department of Ophthalmology, Harvard Medical School/Massachusetts Eye and Ear, Boston, MA, USA
- 2John Sealy School of Medicine, The University of Texas Medical Branch, Galveston, TX, USA
Abstract
Introduction: Refractive surprise is a known risk of cataract surgery in eyes with previous laser refractive surgery or corneal irregularities. In these patients, the use of post-refractive calculators and the preoperative treatment of corneal disease are critical for refractive accuracy.
Case Presentation: A 44-year-old man with a history of laser-assisted in situ keratomileusis (LASIK) presented for cataract evaluation for the left eye. Corneal tomography and examination demonstrated a decentered myopic ablation and LASIK flap macrostriae in the visual axis. The patient underwent cataract surgery at an outside practice with an intraocular lens selected using a post-refractive calculator. The patient returned at postoperative month four due to monocular diplopia and vision of 20/200. Although the postoperative refractive error measured +0.75 −2.25 x 54 via autorefraction, manifest refraction of +4.25 −2.00 x 60 yielded 20/30− vision with resolution of diplopia. The refractive surprise and autorefraction error suggest overestimation of true corneal power due to the prior decentered ablation and the flap macrostriae.
Conclusions: Decentered ablations and corneal surface disease limit the reliability of refractive planning in cataract surgery. Discussing preoperative management of corneal irregularities and refractive expectations is paramount in these cases.
Related
- Does Foveal Morphology Influence Postoperative Refractive Prediction Error Following Cataract Surgery?
- Multicenter evaluation of AI-based intraocular lens formulas and interpretable machine learning for cataract refractive prediction
- Prevalence of Visual Impairment and Effective Cataract and Refractive Error Coverage Among Adults Aged ≥40 Years in the Sundarbans, Eastern India: A Population-Based Rapid Assessment of Avoidable Visual Impairment (RAAVI) Survey
- Ripple-Like Descemet Membrane Folds Following Combined Microhook Ab Interno Trabeculotomy and Cataract Surgery: A Case Report
- Dexamethasone versus triamcinolone acetonide for the management of postoperative inflammation following cataract surgery : A systematic review and meta-analysis
BibTeX
@article{dorsey2026refractive,
title = {{Refractive Surprise following Cataract Surgery in a Patient with a Prior Decentered Myopic Ablation: A Case Report}},
author = {Harold Girum Dorsey and Rahul S. Nanduri and Austin Meeker},
journal = {Case Reports in Ophthalmology},
year = {2026},
month = aug,
doi = {10.1159/cop/acaag001},
url = {https://doi.org/10.1159/cop/acaag001},
note = {CC BY-NC 4.0},
}
RIS
TY - JOUR
TI - Refractive Surprise following Cataract Surgery in a Patient with a Prior Decentered Myopic Ablation: A Case Report
AU - Harold Girum Dorsey
AU - Rahul S. Nanduri
AU - Austin Meeker
PY - 2026
DA - 2026/08/05
JO - Case Reports in Ophthalmology
DO - 10.1159/cop/acaag001
UR - https://doi.org/10.1159/cop/acaag001
AB - Introduction: Refractive surprise is a known risk of cataract surgery in eyes with previous laser refractive surgery or corneal irregularities. In these patients, the use of post-refractive calculators and the preoperative treatment of corneal disease are critical for refractive accuracy. Case Presentation: A 44-year-old man with a history of laser-assisted in situ keratomileusis (LASIK) presented for cataract evaluation for the left eye. Corneal tomography and examination demonstrated a decentered myopic ablation and LASIK flap macrostriae in the visual axis. The patient underwent cataract surgery at an outside practice with an intraocular lens selected using a post-refractive calculator. The patient returned at postoperative month four due to monocular diplopia and vision of 20/200. Although the postoperative refractive error measured +0.75 −2.25 x 54 via autorefraction, manifest refraction of +4.25 −2.00 x 60 yielded 20/30− vision with resolution of diplopia. The refractive surprise and autorefraction error suggest overestimation of true corneal power due to the prior decentered ablation and the flap macrostriae. Conclusions: Decentered ablations and corneal surface disease limit the reliability of refractive planning in cataract surgery. Discussing preoperative management of corneal irregularities and refractive expectations is paramount in these cases.
SN - 1663-2699
ER -