Diagnostic accuracy, time window estimation, and prognostic value of diffusion-weighted MRI in acute ischemic stroke: a systematic review and meta-analysis
- 1Magnetic Resonance, Zhongshan Hospital Affiliated to Xiamen University, 201-209 Hubin South Road, Siming District, Xiamen City, Fujian Province 361004 China
- 2Department of Radiology, Zhongshan Hospital Affiliated to Xiamen University, 201-209 Hubin, South Road, Siming District, Xiamen City, Fujian Province 361004 China
Abstract
Background: Diffusion-weighted imaging (DWI) is central to acute ischemic stroke (AIS) management; however, its performance varies across different clinical applications. This systematic review and meta-analysis comprehensively evaluated the diagnostic accuracy, time window estimation capability, and prognostic value of DWI in AIS.
Methods: This registered systematic review searched three major databases for DWI studies in adult AIS patients published from 2010 to 2025. Risk of bias was assessed using QUADAS-2. The meta-analysis was performed in three distinct phases: (1) diagnostic accuracy, (2) time window estimation, and (3) prognostic value using a bivariate random-effects model. Extensive subgroup analyses were conducted to investigate sources of heterogeneity, including AI assistance, MRI field strength, study design, onset-to-DWI time, sequence type, lesion location, and stroke severity.
Results: Of 34 eligible studies, 22 independent studies with 30 datasets were included in the meta-analysis across three phases. DWI demonstrated excellent diagnostic accuracy with a pooled sensitivity of 0.912 (95% CI: 0.888–0.932) and specificity of 0.959 (95% CI: 0.940–0.970). For time window estimation, DWI showed moderate performance with a pooled sensitivity of 0.786 (95% CI: 0.688–0.860) and specificity of 0.727 (95% CI: 0.668–0.780), with substantial heterogeneity and markedly lower accuracy in posterior circulation strokes. DWI-derived biomarkers demonstrated good prognostic value for predicting functional outcomes with a pooled sensitivity of 0.702 (95% CI: 0.540–0.825) and specificity of 0.904 (95% CI: 0.821–0.951).
Conclusion: DWI offers excellent diagnostic accuracy for AIS (sensitivity: 0.912, specificity: 0.959) but only modest performance for time estimation (sensitivity: 0.786, specificity: 0.727). DWI-derived biomarkers show good prognostic value (sensitivity: 0.702, specificity: 0.904), while AI and ultra-fast MRI protocols demonstrate promise for improving clinical utility.
Study design: Registered systematic review and meta-analysis following PRISMA guidelines
PROSPERO registration: 2026 CRD420261376477.
Supplementary Information: The online version contains supplementary material available at https://doi.org/10.1186/s12880-026-02592-w.
Related
- Diagnostic accuracy of the appendicitis inflammatory response (AIR) score for acute appendicitis during pregnancy: A systematic review and diagnostic meta-analysis
- Diagnostic Accuracy and Renal Safety of Carbon Dioxide Angiography in Lower Limb Angiography: A Systematic Review and Meta-Analysis
- Transthoracic echocardiography vs. cardiac magnetic resonance imaging for the diagnosis of left ventricular thrombus: an updated systematic review and diagnostic accuracy meta-analysis
- Artificial Intelligence-Based Burn Assessment Demonstrates High Diagnostic Accuracy: Systematic Review and Meta-Analysis
- Diagnostic Accuracy of VE1 Immunohistochemistry for BRAF p.V600E in Colorectal Carcinoma: A Systematic Review
BibTeX
@article{wang2026diagnostic,
title = {{Diagnostic accuracy, time window estimation, and prognostic value of diffusion-weighted MRI in acute ischemic stroke: a systematic review and meta-analysis}},
author = {Yueqin Wang and LuXin Guo},
journal = {BMC Medical Imaging},
year = {2026},
month = jul,
doi = {10.1186/s12880-026-02592-w},
url = {https://doi.org/10.1186/s12880-026-02592-w},
note = {CC BY-NC-ND 4.0},
}
RIS
TY - JOUR
TI - Diagnostic accuracy, time window estimation, and prognostic value of diffusion-weighted MRI in acute ischemic stroke: a systematic review and meta-analysis
AU - Yueqin Wang
AU - LuXin Guo
PY - 2026
DA - 2026/07/01
JO - BMC Medical Imaging
DO - 10.1186/s12880-026-02592-w
UR - https://doi.org/10.1186/s12880-026-02592-w
AB - Background: Diffusion-weighted imaging (DWI) is central to acute ischemic stroke (AIS) management; however, its performance varies across different clinical applications. This systematic review and meta-analysis comprehensively evaluated the diagnostic accuracy, time window estimation capability, and prognostic value of DWI in AIS. Methods: This registered systematic review searched three major databases for DWI studies in adult AIS patients published from 2010 to 2025. Risk of bias was assessed using QUADAS-2. The meta-analysis was performed in three distinct phases: (1) diagnostic accuracy, (2) time window estimation, and (3) prognostic value using a bivariate random-effects model. Extensive subgroup analyses were conducted to investigate sources of heterogeneity, including AI assistance, MRI field strength, study design, onset-to-DWI time, sequence type, lesion location, and stroke severity. Results: Of 34 eligible studies, 22 independent studies with 30 datasets were included in the meta-analysis across three phases. DWI demonstrated excellent diagnostic accuracy with a pooled sensitivity of 0.912 (95% CI: 0.888–0.932) and specificity of 0.959 (95% CI: 0.940–0.970). For time window estimation, DWI showed moderate performance with a pooled sensitivity of 0.786 (95% CI: 0.688–0.860) and specificity of 0.727 (95% CI: 0.668–0.780), with substantial heterogeneity and markedly lower accuracy in posterior circulation strokes. DWI-derived biomarkers demonstrated good prognostic value for predicting functional outcomes with a pooled sensitivity of 0.702 (95% CI: 0.540–0.825) and specificity of 0.904 (95% CI: 0.821–0.951). Conclusion: DWI offers excellent diagnostic accuracy for AIS (sensitivity: 0.912, specificity: 0.959) but only modest performance for time estimation (sensitivity: 0.786, specificity: 0.727). DWI-derived biomarkers show good prognostic value (sensitivity: 0.702, specificity: 0.904), while AI and ultra-fast MRI protocols demonstrate promise for improving clinical utility. Study design: Registered systematic review and meta-analysis following PRISMA guidelines PROSPERO registration: 2026 CRD420261376477. Supplementary Information: The online version contains supplementary material available at https://doi.org/10.1186/s12880-026-02592-w.
SN - 1471-2342
ER -