PreprintCC BY-NC-ND 4.0arXiv
Same currents, different field: Δf = 0 carrier-only stimulation is not temporal interference without the beat
Abstract
Carrier-only stimulation (Δf = 0) is generally considered the most rigorous control for temporal interference (TI) stimulation, assumed to reproduce TI's kilohertz carrier field without its low-frequency beat. We show that this assumption is incorrect: without the frequency difference, the carrier fields interfere coherently, changing the peak strength, power, and direction of the resulting field depending on electrode polarity and montage geometry. Using computational field modeling, we demonstrate that these mismatches can be substantial and widespread. We therefore recommend that TI studies report electrode polarity, model both carrier-field exposures, and choose controls according to their study objectives.
Related
- Manipulating Excitation-Inhibition Balance by Temporal Interference Brain Stimulation at Different Frequencies
- Suprathreshold suppression underlies spatial selectivity in temporal interference stimulation
- A Mathematical Characterization of Neural Activation Induced by Temporal Interference Stimulation
- Kilohertz electrical stimulation drives widespread neuronal activation and temporal interference imposes focal rhythmic modulation
- Non-invasive, high-precision, and independently controllable neuromodulation via optimized multiple temporal interference stimulation
BibTeX
@misc{haber2026same,
title = {{Same currents, different field: $Δf = 0$ carrier-only stimulation is not temporal interference without the beat}},
author = {Ido Haber and Giulio Tononi and Larissa Albantakis},
howpublished = {arXiv},
year = {2026},
month = nov,
doi = {10.48550/arxiv.2611.14839},
eprint = {2611.14839},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2611.14839},
note = {CC BY-NC-ND 4.0},
}
RIS
TY - UNPB
TI - Same currents, different field: Δf = 0 carrier-only stimulation is not temporal interference without the beat
AU - Ido Haber
AU - Giulio Tononi
AU - Larissa Albantakis
PY - 2026
DA - 2026/11/10
PB - arXiv
DO - 10.48550/arxiv.2611.14839
UR - https://arxiv.org/abs/2611.14839
AB - Carrier-only stimulation (Δf = 0) is generally considered the most rigorous control for temporal interference (TI) stimulation, assumed to reproduce TI's kilohertz carrier field without its low-frequency beat. We show that this assumption is incorrect: without the frequency difference, the carrier fields interfere coherently, changing the peak strength, power, and direction of the resulting field depending on electrode polarity and montage geometry. Using computational field modeling, we demonstrate that these mismatches can be substantial and widespread. We therefore recommend that TI studies report electrode polarity, model both carrier-field exposures, and choose controls according to their study objectives.
ER -