Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 17 min ago
Peer-reviewedCC BY-NC-ND 4.0Movement Disorders Clinical Practice

Orthostatic Myoclonus—Clinical and Electrophysiological Features in a Large Retrospective Cohort

  1. 1Movement Disorders Unit, Department of Neurology Westmead Hospital Westmead New South Wales Australia
  2. 2Sydney Medical School University of Sydney Sydney New South Wales Australia

Abstract

Background: Orthostatic myoclonus is characterized by irregular, lower limb myoclonic bursts during stance and is a major cause of postural instability and falls. However, studies are limited, and little is known about its pathophysiology.

Objectives: We sought to define the clinical and electrophysiological features of orthostatic myoclonus in a large, single‐center cohort.

Methods: We included 42 participants (24 males, 18 females) with a mean age of 74 years (range, 46–93) from Westmead Hospital presenting with orthostatic myoclonus from 2007 to 2023. Medical records were retrospectively reviewed for demographic details, symptoms, co‐morbidities, and treatment. Lower limb surface electromyography (EMG) was analyzed using a custom‐designed algorithm to automatically identify myoclonic bursts and measure their duration, synchronicity, and rhythmicity. Differences in burst parameters between muscles and associations between burst parameters and clinical characteristics were statistically evaluated.

Results: Mean burst durations during standing were 77 to 90 ms across lower limb muscles. Maximum burst activity and bilateral synchronicity occurred in tibialis anterior. Only 12% of participants exhibited any rhythmicity. A total of 79% of participants had a coexistent neurological disorder including 26% with parkinsonism. There was no significant association between parkinsonism and burst parameters. However, there was a significant, inverse correlation between the presence of neuropathy or radiculopathy and synchronous activity (P = 0.02).

Conclusions: We provide a computationally robust clinical and electrophysiological analysis of orthostatic myoclonus in a large cohort. Our findings support the theory of a subcortical generator arising from protean secondary causes and subject to peripheral modulation. Further work is needed to clarify treatment outcomes.

Related

  1. Functional and Organic Pseudo-Orthostatic Tremor: Clinical Features, Electrophysiology, and Treatment Outcomes in a Retrospective Cohort
    A. Querejeta-Coma, L. M. Yupanqui-Guerra, L. Santos-Sanchez-de-las-Matas +4
    medRxivPreprintCC BYFull textNeurologymedRxiv
  2. Decoding the silent damage: clinical and electrophysiological features associated with occupational n-hexane exposure
    Mehlika PANPALLI ATEŞ, Umur POYRAZ, Mustafa YURTDAŞ +1
    Turkish journal of medical sciencesPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  3. Clinical and radiological features of posterior reversible encephalopathy syndrome in children: a retrospective study
    Hua Huang, Shujuan Jiang, Huan Xu +2
    Frontiers in pediatricsPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. Echocardiographic characteristics and clinical features of cardiac involvement in Behçet’s disease: a retrospective single-center case series
    Wei Wang, Shan Wu, Liling Yang +3
    Quantitative imaging in medicine and surgeryPeer-reviewedCC BY-NC-NDFull textMedical imaging & radiologyEurope PMC
  5. Vitamin B12 deficiency in children in a high-income country: clinical features and outcomes from a 10-year retrospective study
    Riccardo Pagani, Marco Salvi, Davide Colombo +5
    Frontiers in pediatricsPeer-reviewedCC BYFull textGeneral medicineEurope PMC
BibTeX
@article{nagaratnam2026orthostatic,
  title = {{Orthostatic Myoclonus—Clinical and Electrophysiological Features in a Large Retrospective Cohort}},
  author = {Sai A. Nagaratnam and Niroshan Jeyakumar and Gobishan Jeyakumar and Florence Chang and Duncan Wilson and Paloma Becker and Hugo Morales‐Briceno and Neil Mahant and Victor S.C. Fung},
  journal = {Movement Disorders Clinical Practice},
  year = {2026},
  month = jun,
  doi = {10.1002/mdc3.70712},
  url = {https://doi.org/10.1002/mdc3.70712},
  note = {CC BY-NC-ND 4.0},
}
RIS
TY  - JOUR
TI  - Orthostatic Myoclonus—Clinical and Electrophysiological Features in a Large Retrospective Cohort
AU  - Sai A. Nagaratnam
AU  - Niroshan Jeyakumar
AU  - Gobishan Jeyakumar
AU  - Florence Chang
AU  - Duncan Wilson
AU  - Paloma Becker
AU  - Hugo Morales‐Briceno
AU  - Neil Mahant
AU  - Victor S.C. Fung
PY  - 2026
DA  - 2026/06/19
JO  - Movement Disorders Clinical Practice
DO  - 10.1002/mdc3.70712
UR  - https://doi.org/10.1002/mdc3.70712
AB  - Background: Orthostatic myoclonus is characterized by irregular, lower limb myoclonic bursts during stance and is a major cause of postural instability and falls. However, studies are limited, and little is known about its pathophysiology.  Objectives: We sought to define the clinical and electrophysiological features of orthostatic myoclonus in a large, single‐center cohort.  Methods: We included 42 participants (24 males, 18 females) with a mean age of 74 years (range, 46–93) from Westmead Hospital presenting with orthostatic myoclonus from 2007 to 2023. Medical records were retrospectively reviewed for demographic details, symptoms, co‐morbidities, and treatment. Lower limb surface electromyography (EMG) was analyzed using a custom‐designed algorithm to automatically identify myoclonic bursts and measure their duration, synchronicity, and rhythmicity. Differences in burst parameters between muscles and associations between burst parameters and clinical characteristics were statistically evaluated.  Results: Mean burst durations during standing were 77 to 90 ms across lower limb muscles. Maximum burst activity and bilateral synchronicity occurred in tibialis anterior. Only 12% of participants exhibited any rhythmicity. A total of 79% of participants had a coexistent neurological disorder including 26% with parkinsonism. There was no significant association between parkinsonism and burst parameters. However, there was a significant, inverse correlation between the presence of neuropathy or radiculopathy and synchronous activity (P = 0.02).  Conclusions: We provide a computationally robust clinical and electrophysiological analysis of orthostatic myoclonus in a large cohort. Our findings support the theory of a subcortical generator arising from protean secondary causes and subject to peripheral modulation. Further work is needed to clarify treatment outcomes.
SN  - 2330-1619
ER  -