Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 54 min ago
PreprintCC BY 4.0PsyArXiv

Observed Interpersonal Physiological Synchrony Is Not Interpersonal Coupling: Identification Depends on the Observation, Design, and Inference Pipeline

Abstract

Interpersonal physiological synchrony (IPS) is widely read as a marker of mutual influence between people, yet two hearts can move together without any influence between them. A shared stimulus, a shared breathing rhythm, or each person's own respiration-to-heart pathway can produce the same observed synchrony as genuine interpersonal coupling. We treat this as an identification problem and ask, in a series of preregistered simulations of dyadic heart and respiration recordings, which parts of the analysis pipeline decide whether coupling can be recovered. Omitting respiration distorted coupling estimates in both a phase-oscillator and a linear-oscillator representation. With idealized phase observations, a respiration-conditioned latent-phase Kalman estimator recovered coupling, kept its relation to a latent relationship state, and resisted shared respiratory input. Once heart and respiration phases were extracted as in real recordings (band-pass filtering and Hilbert transform of the respiratory-band heart-rate oscillation), three things changed. First, model-based intervals were too narrow by a factor of 2 to 4 for both the Kalman estimator and a published alternative, dynamical Bayesian inference, so that 39 to 40% of uncoupled dyads were declared coupled; surrogate (pseudo-pair) thresholds restored nominal error rates. Second, when susceptibility to a shared respiratory input varied across dyads, both respiration-conditioned estimators lost their relation to the relationship state (r from .43 to .06) and became negatively related to the shared-input susceptibility. An exploratory diagnosis located this failure in the extraction of the cardiac phase rather than in respiration measurement or in a trade-off between coupling and respiratory-pull parameters. Third, group-level design contrasts corrected the over-confidence of dyad-level intervals but not this systematic bias: a double difference built on an identical breathing pacer for both partners failed completely, whereas the same contrast with partners paced at frequencies 0.02 Hz apart kept nominal false-positive rates and full power with 20 recruited dyads. Coupling inference therefore depends less on the choice of estimator than on the whole observation, design, and inference pipeline. We recommend measuring respiration, calibrating coupling decisions against design-matched surrogate nulls, and, where possible, decorrelating shared inputs between partners by design.

Related

  1. An embedded and embodied neuroscience of interpersonal synchrony
    Manuel Varlet, Michael J Richardson
    Oxford Open NeurosciencePeer-reviewedCC BY 4.0Full textNeurosciencePMC
  2. Social relationship is associated with distinct patterns of inter-brain synchrony and directed connectivity during interpersonal coordination
    Huixin Han, Zhongqi Zhao, Liyue Lin +2
    Social Cognitive and Affective NeurosciencePeer-reviewedCC BY-NC-ND 4.0Full textNeurosciencePMC
  3. Loss contexts enhance dorsolateral prefrontal interpersonal neural synchrony during successful human deceptive recommendations
    Yaozhong Liu, Rui Huang, Xiaowei Gao +5
    Communications BiologyPeer-reviewedCC BYFull textGeneral biologyDOAJ
  4. Interpersonal Synchrony During a Client-Therapist Role-Play Interaction: The Role of Modalities, Facets, and Relational Context.
    Noha M Yassen, Jacobien M van Peer, Ger P J Keijsers +2
    PsychophysiologyPeer-reviewedCC BYFull textNeuroscienceEurope PMCPMC
  5. Infant-caregiver vocal contingency changes across varying interpersonal space
    Narain Viswanathan, Giovanni Esposito, Pierre Labendzki +7
    Infant Behavior and DevelopmentPeer-reviewedPublisher termsFull textNeuroscienceHAL
BibTeX
@misc{lee2026observed,
  title = {{Observed Interpersonal Physiological Synchrony Is Not Interpersonal Coupling: Identification Depends on the Observation, Design, and Inference Pipeline}},
  author = {Jeongeun Lee},
  howpublished = {PsyArXiv},
  year = {2026},
  month = nov,
  doi = {10.31234/osf.io/fvj7w_v1},
  url = {https://osf.io/preprints/psyarxiv/fvj7w_v1/},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - Observed Interpersonal Physiological Synchrony Is Not Interpersonal Coupling: Identification Depends on the Observation, Design, and Inference Pipeline
AU  - Jeongeun Lee
PY  - 2026
DA  - 2026/11/18
PB  - PsyArXiv
DO  - 10.31234/osf.io/fvj7w_v1
UR  - https://osf.io/preprints/psyarxiv/fvj7w_v1/
AB  - Interpersonal physiological synchrony (IPS) is widely read as a marker of mutual influence between people, yet two hearts can move together without any influence between them. A shared stimulus, a shared breathing rhythm, or each person's own respiration-to-heart pathway can produce the same observed synchrony as genuine interpersonal coupling. We treat this as an identification problem and ask, in a series of preregistered simulations of dyadic heart and respiration recordings, which parts of the analysis pipeline decide whether coupling can be recovered. Omitting respiration distorted coupling estimates in both a phase-oscillator and a linear-oscillator representation. With idealized phase observations, a respiration-conditioned latent-phase Kalman estimator recovered coupling, kept its relation to a latent relationship state, and resisted shared respiratory input. Once heart and respiration phases were extracted as in real recordings (band-pass filtering and Hilbert transform of the respiratory-band heart-rate oscillation), three things changed. First, model-based intervals were too narrow by a factor of 2 to 4 for both the Kalman estimator and a published alternative, dynamical Bayesian inference, so that 39 to 40% of uncoupled dyads were declared coupled; surrogate (pseudo-pair) thresholds restored nominal error rates. Second, when susceptibility to a shared respiratory input varied across dyads, both respiration-conditioned estimators lost their relation to the relationship state (r from .43 to .06) and became negatively related to the shared-input susceptibility. An exploratory diagnosis located this failure in the extraction of the cardiac phase rather than in respiration measurement or in a trade-off between coupling and respiratory-pull parameters. Third, group-level design contrasts corrected the over-confidence of dyad-level intervals but not this systematic bias: a double difference built on an identical breathing pacer for both partners failed completely, whereas the same contrast with partners paced at frequencies 0.02 Hz apart kept nominal false-positive rates and full power with 20 recruited dyads. Coupling inference therefore depends less on the choice of estimator than on the whole observation, design, and inference pipeline. We recommend measuring respiration, calibrating coupling decisions against design-matched surrogate nulls, and, where possible, decorrelating shared inputs between partners by design.
ER  -