Balancing Directions and Averages for Cardiac Diffusion Tensor Imaging Using a Moderate Gradient Performance System.
4 affiliations
- 1Department of Radiology, Stanford University, Stanford, California, USA.
- 2Division of Radiology, Veterans Administration Health Care System, Palo Alto, California, USA.
- 3Cardiovascular Institute, Stanford University, Stanford, California, USA.
- 4Department of Bioengineering, Stanford University, Stanford, California, USA.
Abstract
Cardiac diffusion tensor imaging (cDTI) is an inherently low signal-to-noise ratio technique while also having long scan times. This generally results in suboptimal image quality, especially for systems with moderate gradient performance, for fixed durations of scan time. The aim of this study was to evaluate several diffusion encoding schemes (DES) on a moderate gradient performance, 3T scanner, while fixing the number of diffusion-weighted images to objectively determine which DES yielded superior results. Spin-echo cDTI protocols spanning six DES were evaluated in healthy subjects (N = 10). Each DES used a combination diffusion directions (N dir ) and signal averages (N avg ). Mean diffusivity (MD), fractional anisotropy (FA), and the helix angle pitch (HAP), plus MD uncertainty ( d MD), FA uncertainty ( d FA), and the primary eigenvector uncertainty ( de→1 ) were analyzed for statistical differences (p < 0.05). The technique for order of preference by similarity to ideal solution (TOPSIS) method was used to identify which DES yielded superior results. DES with lower N dir /higher N avg had lower FA, d MD, and d FA. As N dir increased/N avg decreased, FA, d MD, and d FA increased. Inversely, DES with lower N dir /higher N avg had a higher de→1 , while N dir increased/N avg decreased, the de→1 decreased. The HAP had a parabolic trend where both DES with lower N dir /higher N avg and DES with higher N dir /lower N avg were not as steep as DES with moderate N dir /moderate N avg . The DES with moderate N dir (15)/moderate N avg (4) yielded the most superior results. This work provides a framework for evaluating the best DES for cDTI on systems with moderate gradient performance.
Related
- Effects of Acute Carbohydrate–Electrolyte Supplementation on Exercise Performance in Moderate-to-Hot Ambient Conditions: A Systematic Review and Meta-Analysis
- Diagnostic Performance of a Deep Learning Model Using Phonocardiogram and Single‐Lead ECG Signals for Detecting Moderate‐or‐Greater Aortic Stenosis: Multicenter External Validation
- Diagnostic error in veterinary imaging: an underexplored field and future directions for observer performance research
- Maximal Fat Oxidation Is Associated With Moderate- and High-Speed Running Performance During Competitive Matches in Youth National-Level Football Players: A Retrospective In-Season Study
- Serum Calprotectin Demonstrates Moderate Diagnostic Performance for Detecting Periprosthetic Joint Infection in Hip and Knee Arthroplasty
BibTeX
@article{cork2026balancing,
title = {{Balancing Directions and Averages for Cardiac Diffusion Tensor Imaging Using a Moderate Gradient Performance System.}},
author = {Tyler E Cork and Ariel J Hannum and Matthew J Middione and Daniel B Ennis},
journal = {NMR in biomedicine},
year = {2026},
month = nov,
doi = {10.1002/nbm.70445},
url = {https://europepmc.org/article/MED/43081910},
note = {CC BY-NC},
}
RIS
TY - JOUR
TI - Balancing Directions and Averages for Cardiac Diffusion Tensor Imaging Using a Moderate Gradient Performance System.
AU - Tyler E Cork
AU - Ariel J Hannum
AU - Matthew J Middione
AU - Daniel B Ennis
PY - 2026
DA - 2026/11/26
JO - NMR in biomedicine
DO - 10.1002/nbm.70445
UR - https://europepmc.org/article/MED/43081910
AB - Cardiac diffusion tensor imaging (cDTI) is an inherently low signal-to-noise ratio technique while also having long scan times. This generally results in suboptimal image quality, especially for systems with moderate gradient performance, for fixed durations of scan time. The aim of this study was to evaluate several diffusion encoding schemes (DES) on a moderate gradient performance, 3T scanner, while fixing the number of diffusion-weighted images to objectively determine which DES yielded superior results. Spin-echo cDTI protocols spanning six DES were evaluated in healthy subjects (N = 10). Each DES used a combination diffusion directions (N dir ) and signal averages (N avg ). Mean diffusivity (MD), fractional anisotropy (FA), and the helix angle pitch (HAP), plus MD uncertainty ( d MD), FA uncertainty ( d FA), and the primary eigenvector uncertainty ( de→1 ) were analyzed for statistical differences (p < 0.05). The technique for order of preference by similarity to ideal solution (TOPSIS) method was used to identify which DES yielded superior results. DES with lower N dir /higher N avg had lower FA, d MD, and d FA. As N dir increased/N avg decreased, FA, d MD, and d FA increased. Inversely, DES with lower N dir /higher N avg had a higher de→1 , while N dir increased/N avg decreased, the de→1 decreased. The HAP had a parabolic trend where both DES with lower N dir /higher N avg and DES with higher N dir /lower N avg were not as steep as DES with moderate N dir /moderate N avg . The DES with moderate N dir (15)/moderate N avg (4) yielded the most superior results. This work provides a framework for evaluating the best DES for cDTI on systems with moderate gradient performance.
SN - 0952-3480
SN - 1099-1492
ER -