Peer-reviewedCC BYEuropean heart journal. Imaging methods and practice

Assessment of cardiac image quality from single-probe handheld ultrasound devices.

3 more authors
6 affiliations
  1. 1Department of Medicine, Tufts Medical Center, Boston, MA, USA.
  2. 2Institute for Clinical Research and Health Policy Studies, Tufts Medical Center, Boston, MA, USA.
  3. 3Tufts Clinical and Translational Science Institute, Tufts Medical Center, Tufts University, Boston, MA, USA.
  4. 4Department of Computer Science, Tufts University, Medford, MA, USA.
  5. 5Cardiovascular Center, Tufts Medical Center, Boston, MA, USA.
  6. 6Predictive Analytics and Comparative Effectiveness (PACE) Center, Tufts Medical Center, Boston, MA, USA.

Abstract

Aims

This study aims to assess quality of cardiac ultrasound imaging from commercially available single-probe handheld devices.Methods and results

Cardiac imaging from single-probe handheld ultrasound devices was prospectively acquired by registered cardiac sonographers. Videos were graded on a scale of 1 (uninterpretable) to 5 (diagnostic-quality imaging) by 2 sonographers. The average image quality score for each cine loop was analysed. Interpretable imaging was defined as an average IQ score ≥ 2. Good image quality was defined as an average IQ score ≥ 4. Imaging from single-probe devices representing 518 videos from 206 patients was assessed. The mean age was 72 (SD 11.1) years. Agreement on image quality was moderate (weighted kappa 0.50, 95% CI 0.45-0.55). The correlation between sonographer quality grades was 0.60. The median average IQ score was 2.5 (1.5). 454 (88%) of the videos were interpretable (average IQ ≥ 2). At least one interpretable video was obtained for 187 (91%) patients. 62/518 (12%) of videos had good image quality (average score ≥ 4). There was a trend towards lower image quality with increasing BMI categories [16-25, median 3.0 (2.0, 3.5), 25-29, median 3.0 (2.0, 3.5), > 29 median 2.5 (2.0, 3.0), P < 0.001].Conclusion

Basic interpretable imaging from single-probe handheld ultrasound devices can be obtained for most patients under idealized conditions, suggesting possible use for enhanced cardiac disease detection. Since imaging from a significant minority of patients is uninterpretable and lower image quality is associated with higher BMI, rigorous assessment of image quality is essential prior to image interpretation.

Related

  1. Handheld Ultrasound Implementation and Structured Point‐of‐Care Ultrasound Training Across the Indo‐Pacific: Programmatic Lessons From the PEARLS Program
    Wai Chung Tse, Theodore Ajluni, Micah Misivet +5
    Australasian Journal of Ultrasound in MedicinePeer-reviewedLicence not statedFull textGeneral medicinePMC
  2. Handheld Ultrasound: Technical Review and International Expert Consensus Recommendations
    Christoph F. Dietrich, Michael Blaivas, Vito Cantisani +14
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  3. A Comparative Review of Performance and Concurrent Cardiac Rhythm Assessment Across Home Sleep Apnea Testing Devices.
    Brian Brockway, Arjun Sharma, Clara Stein +2
    CureusPeer-reviewedCC BYFull textCardiovascular medicineEurope PMCPMC
  4. Ultrasound-based assessment of cardiac and hepatic dysfunction: current status and future directions.
    Yin-Xia Li, Lei Chen, Peng Chen +2
    Cardiovascular ultrasoundPeer-reviewedCC BY-NC-NDFull textCardiovascular medicineEurope PMCPMC
  5. Agreement Between Handheld and Fixed Dynamometry for Hip Strength Assessment in Young Soccer Players and Non-Soccer Controls: An Exploratory Study
    Rafał Borkowski, Jakub Grodzki, Patrycja Adamska
    Journal of Clinical MedicinePeer-reviewedCC BY 4.0General medicineCrossref
BibTeX
@article{grimaldo2026assessment,
  title = {{Assessment of cardiac image quality from single-probe handheld ultrasound devices.}},
  author = {Anna Grimaldo and Benjamin Koethe and Shane Williams and Eileen W Mai and Joseph Nguyen and Monica M Dehn and Lisa Small and Jennie An and Veronique Recile and Denise Daudelin and Ludovic Trinquart and David M Kent and Ayan R Patel and Michael Hughes and Benjamin S Wessler},
  journal = {European heart journal. Imaging methods and practice},
  year = {2026},
  month = oct,
  doi = {10.1093/ehjimp/qyag172},
  url = {https://europepmc.org/article/MED/42910194},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Assessment of cardiac image quality from single-probe handheld ultrasound devices.
AU  - Anna Grimaldo
AU  - Benjamin Koethe
AU  - Shane Williams
AU  - Eileen W Mai
AU  - Joseph Nguyen
AU  - Monica M Dehn
AU  - Lisa Small
AU  - Jennie An
AU  - Veronique Recile
AU  - Denise Daudelin
AU  - Ludovic Trinquart
AU  - David M Kent
AU  - Ayan R Patel
AU  - Michael Hughes
AU  - Benjamin S Wessler
PY  - 2026
DA  - 2026/10/06
JO  - European heart journal. Imaging methods and practice
DO  - 10.1093/ehjimp/qyag172
UR  - https://europepmc.org/article/MED/42910194
AB  - Aims  This study aims to assess quality of cardiac ultrasound imaging from commercially available single-probe handheld devices.Methods and results  Cardiac imaging from single-probe handheld ultrasound devices was prospectively acquired by registered cardiac sonographers. Videos were graded on a scale of 1 (uninterpretable) to 5 (diagnostic-quality imaging) by 2 sonographers. The average image quality score for each cine loop was analysed. Interpretable imaging was defined as an average IQ score ≥ 2. Good image quality was defined as an average IQ score ≥ 4. Imaging from single-probe devices representing 518 videos from 206 patients was assessed. The mean age was 72 (SD 11.1) years. Agreement on image quality was moderate (weighted kappa 0.50, 95% CI 0.45-0.55). The correlation between sonographer quality grades was 0.60. The median average IQ score was 2.5 (1.5). 454 (88%) of the videos were interpretable (average IQ ≥ 2). At least one interpretable video was obtained for 187 (91%) patients. 62/518 (12%) of videos had good image quality (average score ≥ 4). There was a trend towards lower image quality with increasing BMI categories [16-25, median 3.0 (2.0, 3.5), 25-29, median 3.0 (2.0, 3.5), > 29 median 2.5 (2.0, 3.0), P < 0.001].Conclusion  Basic interpretable imaging from single-probe handheld ultrasound devices can be obtained for most patients under idealized conditions, suggesting possible use for enhanced cardiac disease detection. Since imaging from a significant minority of patients is uninterpretable and lower image quality is associated with higher BMI, rigorous assessment of image quality is essential prior to image interpretation.
SN  - 2755-9637
ER  -