Elevated Doppler-estimated right ventricular systolic pressure in complete atrioventricular block and its response to atrioventricular-synchronous pacing
- 1Division of Cardiology, Department of Internal Medicine, Dongkang Medical Center
Abstract
Background: Complete atrioventricular block causes both bradycardia and loss of atrioventricular synchrony. Case reports have described marked elevations in Doppler-estimated right ventricular systolic pressure that fall after pacing, but the prevalence and consistency of this phenotype have not been examined in a cohort.
Methods: We retrospectively studied consecutive patients in sinus rhythm with complete atrioventricular block and a left ventricular ejection fraction of at least 50%, identified from 142 permanent pacemaker implantations at one center between 2021 and 2026. Right atrial pressure was estimated using current guideline categories. The prespecified primary endpoint was the paired change in Doppler-estimated right ventricular systolic pressure between the native state and the first study within 72 h of atrioventricular-synchronous pacing. Tricuspid regurgitant signal quality was graded on envelope completeness and analyzed alongside it.
Results: Thirty patients formed the native cohort and 14 had paired studies. Doppler-estimated right ventricular systolic pressure was 44.0 mmHg (interquartile range 32.4–50.3) during native block and was 35 mmHg or greater in 21 patients. In the paired cohort it fell from 46.6 to 25.0 mmHg in all 14 patients (median relative change −51.4%; P < 0.001), and the proportion with values of 35 mmHg or greater fell from 11 to 3 ( P = 0.008). Both the tricuspid regurgitant gradient and the estimated right atrial pressure decreased, and tricuspid regurgitation grade fell in 7 patients and increased in none. Paced QRS duration increased, and the heart-rate change was not correlated with the change in Doppler-estimated right ventricular systolic pressure. Signal quality tended to decline after pacing; in a post hoc analysis restricted to the 7 patients in whom it was unchanged or improved, the reduction persisted (median relative change −33.8%; P = 0.016). In four catheterized patients, Doppler estimates diverged from invasive pressures in both directions.
Conclusion: Elevated Doppler-estimated right ventricular systolic pressure was common during complete atrioventricular block and fell consistently after atrioventricular-synchronous pacing. Because signal quality changed concurrently and invasive pressure did not invariably track the estimate, the magnitude of the observed Doppler reduction, and whether pulmonary artery pressure itself falls, remain uncertain.
Related
- Persistence of atrioventricular nodal re-entrant tachycardia during ventricular fibrillation.
- Left Bundle-Branch Area Pacing vs Right Ventricular Pacing for Atrioventricular Block and Preserved Left Ventricular Function
- Graves’ Disease and the Heart: Severe Reversible Left Ventricular Systolic Dysfunction With Apical Thrombus in a Young Woman With Relapsed Thyrotoxicosis
- Nebivolol for the Prevention of Left Ventricular Systolic Dysfunction in Patients With Duchenne Muscular Dystrophy: the NEBIDYS trial
- Development and Population-Based Prognostic Utility Assessment of an ICD-10-CM-Based Prediction Model to Identify Left Ventricular Systolic Dysfunction: Discrimination Performance and Population-Based Evaluation in 83,357 Patients with Acute Coronary Syndrome
BibTeX
@article{son2026elevated,
title = {{Elevated Doppler-estimated right ventricular systolic pressure in complete atrioventricular block and its response to atrioventricular-synchronous pacing}},
author = {Byeng-Ju Son and Sungyun Jung and Byung-Jun Kim and Hong-Ju Kim and Hyongjun Kim},
journal = {Frontiers in Cardiovascular Medicine},
year = {2026},
month = oct,
doi = {10.3389/fcvm.2026.1967085},
url = {https://www.frontiersin.org/articles/10.3389/fcvm.2026.1967085/full},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Elevated Doppler-estimated right ventricular systolic pressure in complete atrioventricular block and its response to atrioventricular-synchronous pacing
AU - Byeng-Ju Son
AU - Sungyun Jung
AU - Byung-Jun Kim
AU - Hong-Ju Kim
AU - Hyongjun Kim
PY - 2026
DA - 2026/10/28
JO - Frontiers in Cardiovascular Medicine
DO - 10.3389/fcvm.2026.1967085
UR - https://www.frontiersin.org/articles/10.3389/fcvm.2026.1967085/full
AB - Background: Complete atrioventricular block causes both bradycardia and loss of atrioventricular synchrony. Case reports have described marked elevations in Doppler-estimated right ventricular systolic pressure that fall after pacing, but the prevalence and consistency of this phenotype have not been examined in a cohort. Methods: We retrospectively studied consecutive patients in sinus rhythm with complete atrioventricular block and a left ventricular ejection fraction of at least 50%, identified from 142 permanent pacemaker implantations at one center between 2021 and 2026. Right atrial pressure was estimated using current guideline categories. The prespecified primary endpoint was the paired change in Doppler-estimated right ventricular systolic pressure between the native state and the first study within 72 h of atrioventricular-synchronous pacing. Tricuspid regurgitant signal quality was graded on envelope completeness and analyzed alongside it. Results: Thirty patients formed the native cohort and 14 had paired studies. Doppler-estimated right ventricular systolic pressure was 44.0 mmHg (interquartile range 32.4–50.3) during native block and was 35 mmHg or greater in 21 patients. In the paired cohort it fell from 46.6 to 25.0 mmHg in all 14 patients (median relative change −51.4%; P < 0.001), and the proportion with values of 35 mmHg or greater fell from 11 to 3 ( P = 0.008). Both the tricuspid regurgitant gradient and the estimated right atrial pressure decreased, and tricuspid regurgitation grade fell in 7 patients and increased in none. Paced QRS duration increased, and the heart-rate change was not correlated with the change in Doppler-estimated right ventricular systolic pressure. Signal quality tended to decline after pacing; in a post hoc analysis restricted to the 7 patients in whom it was unchanged or improved, the reduction persisted (median relative change −33.8%; P = 0.016). In four catheterized patients, Doppler estimates diverged from invasive pressures in both directions. Conclusion: Elevated Doppler-estimated right ventricular systolic pressure was common during complete atrioventricular block and fell consistently after atrioventricular-synchronous pacing. Because signal quality changed concurrently and invasive pressure did not invariably track the estimate, the magnitude of the observed Doppler reduction, and whether pulmonary artery pressure itself falls, remain uncertain.
SN - 2297-055X
ER -