Fluoride label concordance, pH, and electrical conductivity of commercial bottled waters in Ecuador
- 1Facultad de Ciencias de la Salud Eugenio Espejo, Carrera de Odontología, Universidad UTE , , ,
- 2Facultad de Ciencias Médicas, Carrera de Odontología, Universidad Católica de Santiago de Guayaquil , , ,
- 3Departamento de Ciencias de la Vida y la Agricultura, Universidad de las Fuerzas Armadas ESPE , , ,
Abstract
Background
Bottled water is widely consumed, yet differing water sources and manufacturing processes may alter its physicochemical properties, with reported discrepancies between label declarations and laboratory analyses. Given the lack of regional evidence, this study aimed to determine the fluoride concentration, pH, electrical conductivity, and labeling concordance of commercial bottled waters in Ecuador.Methods
Eighteen commercial bottled water brands in Ecuador were analyzed to determine fluoride concentration (mg/L), pH, and electrical conductivity (µS/cm). Differences across brands and associations among variables were evaluated using one-way ANOVA and Spearman rank correlation (α = 0.05).Results
Discrepancies between declared and laboratory-measured fluoride levels were identified in 10 brands (55.6%). Only two brands exhibited fluoride concentrations within the recommended range established by international health organizations (0.7-1.5 mg/L) for caries prevention: Omizu Sparkling (0.85 ± 0.07 mg/L) and Aki (1.45 ± 0.04 mg/L), with the latter approaching the maximum safety limit. Notably, Omizu Sparkling also presented the highest labeling discrepancy (325%). Physicochemical parameters differ significantly among brands across brands (p < 0.01). Additionally, 50% of the brands evaluated exhibited pH values at or below the critical threshold for enamel demineralization (≤ 5.5). Electrical conductivity correlated positively with measured fluoride concentrations (r = 0.592, p < 0.001).Conclusions
Bottled waters in Ecuador predominantly present sub-optimal fluoride levels and potentially erosive pH values. These findings highlight the need for stricter regulatory labeling enforcement and heightened clinical awareness among dental professionals.
Related
- Reconstructing the spatiotemporal distribution of microbial-induced carbonate precipitation using electrical conductivity tomography
- Remote effect of anisotropy in electrical conductivity or magnetic permeability on dynamo action
- Low electrical conductivity of dry CaSiO3 perovskite under lower mantle conditions
- Relationship between soil electrical conductivity and water content: A multiscale petrophysical calibration
- Overestimation of meltwater fractions due to temperature bias in electrical conductivity-based hydrograph separation models in the Himalayas
BibTeX
@article{vega2026fluoride,
title = {{Fluoride label concordance, pH, and electrical conductivity of commercial bottled waters in Ecuador}},
author = {Ana Armas Vega and María Christel Zambrano Bonilla and Fernando Armas-Vega and María Fernanda Chamba Macas and Elizabeth Urbano Salazar and Byron Carpio-Salvatierra},
journal = {Frontiers in oral health},
year = {2026},
month = nov,
doi = {10.3389/froh.2026.2018749},
url = {https://europepmc.org/article/PMC/PMC13793537},
note = {CC BY},
}
RIS
TY - JOUR
TI - Fluoride label concordance, pH, and electrical conductivity of commercial bottled waters in Ecuador
AU - Ana Armas Vega
AU - María Christel Zambrano Bonilla
AU - Fernando Armas-Vega
AU - María Fernanda Chamba Macas
AU - Elizabeth Urbano Salazar
AU - Byron Carpio-Salvatierra
PY - 2026
DA - 2026/11/10
JO - Frontiers in oral health
DO - 10.3389/froh.2026.2018749
UR - https://europepmc.org/article/PMC/PMC13793537
AB - Background Bottled water is widely consumed, yet differing water sources and manufacturing processes may alter its physicochemical properties, with reported discrepancies between label declarations and laboratory analyses. Given the lack of regional evidence, this study aimed to determine the fluoride concentration, pH, electrical conductivity, and labeling concordance of commercial bottled waters in Ecuador.Methods Eighteen commercial bottled water brands in Ecuador were analyzed to determine fluoride concentration (mg/L), pH, and electrical conductivity (µS/cm). Differences across brands and associations among variables were evaluated using one-way ANOVA and Spearman rank correlation (α = 0.05).Results Discrepancies between declared and laboratory-measured fluoride levels were identified in 10 brands (55.6%). Only two brands exhibited fluoride concentrations within the recommended range established by international health organizations (0.7-1.5 mg/L) for caries prevention: Omizu Sparkling (0.85 ± 0.07 mg/L) and Aki (1.45 ± 0.04 mg/L), with the latter approaching the maximum safety limit. Notably, Omizu Sparkling also presented the highest labeling discrepancy (325%). Physicochemical parameters differ significantly among brands across brands (p < 0.01). Additionally, 50% of the brands evaluated exhibited pH values at or below the critical threshold for enamel demineralization (≤ 5.5). Electrical conductivity correlated positively with measured fluoride concentrations (r = 0.592, p < 0.001).Conclusions Bottled waters in Ecuador predominantly present sub-optimal fluoride levels and potentially erosive pH values. These findings highlight the need for stricter regulatory labeling enforcement and heightened clinical awareness among dental professionals.
SN - 2673-4842
ER -