Bedside Lung Ultrasound for Early Postoperative Risk Stratification for Prolonged Mechanical Ventilation After Liver Transplantation
- 1Intensive Care Unit, China-Japan Friendship Hospital, 2 Yinghua Dongjie, Beijing 100029, China
- 2Department of General Surgery, China-Japan Friendship Hospital, 2 Yinghua Dongjie, Beijing 100029, China
Abstract
Objectives: Pulmonary complications remain a major determinant of postoperative morbidity following liver transplantation and frequently lead to prolonged mechanical ventilation (PMV). This study aimed to evaluate the value of lung ultrasound (LUS) for early postoperative risk stratification of PMV and to develop a multivariable model integrating LUS with conventional clinical variables. Methods: In this prospective cohort study, 116 adults undergoing primary liver transplantation were enrolled. A standardized 12-zone LUS examination was performed within 1–3 h of ICU admission. PMV was defined as the need for mechanical ventilation for ≥24 h. Multivariable logistic regression analysis was constructed by sequentially incorporating perioperative variables and postoperative PaO2/FiO2, followed by LUS. Model performance was evaluated using discrimination, calibration, bootstrap internal validation, and decision curve analysis. Results: PMV occurred in 39.7% (n = 46) of the patients. Those requiring PMV had significantly higher early postoperative LUS scores than patients extubated within 24 h (median: 18.0 vs. 12.0, p < 0.001). LUS scores were inversely correlated with oxygenation (SpO2/FiO2 ratio, ⍴ = −0.615, p < 0.001). LUS remained independently associated with PMV (OR = 1.52, 95% CI: 1.27–1.83). LUS alone demonstrated good discrimination (AUC: 0.830). After postoperative PaO2/FiO2 was included in the clinical model, incorporation of LUS significantly improved model discrimination (AUC: 0.935, 95% CI: 0.894–0.976) compared with the model without LUS (AUC: 0.862, DeLong p = 0.011). Decision curve analysis showed greater net benefit of the LUS-integrated model across clinically relevant threshold probabilities. Conclusions: Early postoperative LUS is independently associated with prolonged mechanical ventilation after liver transplantation. Integration of LUS into a multivariable framework provides incremental prognostic information beyond conventional postoperative respiratory assessment and may improve early postoperative risk stratification. External validation is required before clinical implementation.
Related
- Combined Approach with Ultrasound and Pressure–Volume Loops to Manage Mechanical Ventilation in Acute Hypoxemic Respiratory Failure
- Early postoperative galectin-3 for risk stratification of delayed graft function after kidney transplantation
- Effect of intraoperative high positive end-expiratory pressure with recruitment manoeuvres versus low positive end-expiratory pressure on postoperative lung function in obese adults: a substudy of the protective ventilation in obese patients randomised controlled trial
- Driving pressure, simplified elastic mechanical power, and time to liberation from mechanical ventilation: a competing-risks and time-anchored observational study
- Mechanical ventilation in acute brain injury
BibTeX
@article{wang2026bedside,
title = {{Bedside Lung Ultrasound for Early Postoperative Risk Stratification for Prolonged Mechanical Ventilation After Liver Transplantation}},
author = {Hui Wang and Yongyi Chen and Dongdong Han and Jun Duan},
journal = {Journal of Clinical Medicine},
year = {2026},
month = oct,
doi = {10.3390/jcm15208100},
url = {https://www.mdpi.com/2077-0383/15/20/8100},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Bedside Lung Ultrasound for Early Postoperative Risk Stratification for Prolonged Mechanical Ventilation After Liver Transplantation
AU - Hui Wang
AU - Yongyi Chen
AU - Dongdong Han
AU - Jun Duan
PY - 2026
DA - 2026/10/01
JO - Journal of Clinical Medicine
DO - 10.3390/jcm15208100
UR - https://www.mdpi.com/2077-0383/15/20/8100
AB - Objectives: Pulmonary complications remain a major determinant of postoperative morbidity following liver transplantation and frequently lead to prolonged mechanical ventilation (PMV). This study aimed to evaluate the value of lung ultrasound (LUS) for early postoperative risk stratification of PMV and to develop a multivariable model integrating LUS with conventional clinical variables. Methods: In this prospective cohort study, 116 adults undergoing primary liver transplantation were enrolled. A standardized 12-zone LUS examination was performed within 1–3 h of ICU admission. PMV was defined as the need for mechanical ventilation for ≥24 h. Multivariable logistic regression analysis was constructed by sequentially incorporating perioperative variables and postoperative PaO2/FiO2, followed by LUS. Model performance was evaluated using discrimination, calibration, bootstrap internal validation, and decision curve analysis. Results: PMV occurred in 39.7% (n = 46) of the patients. Those requiring PMV had significantly higher early postoperative LUS scores than patients extubated within 24 h (median: 18.0 vs. 12.0, p < 0.001). LUS scores were inversely correlated with oxygenation (SpO2/FiO2 ratio, ⍴ = −0.615, p < 0.001). LUS remained independently associated with PMV (OR = 1.52, 95% CI: 1.27–1.83). LUS alone demonstrated good discrimination (AUC: 0.830). After postoperative PaO2/FiO2 was included in the clinical model, incorporation of LUS significantly improved model discrimination (AUC: 0.935, 95% CI: 0.894–0.976) compared with the model without LUS (AUC: 0.862, DeLong p = 0.011). Decision curve analysis showed greater net benefit of the LUS-integrated model across clinically relevant threshold probabilities. Conclusions: Early postoperative LUS is independently associated with prolonged mechanical ventilation after liver transplantation. Integration of LUS into a multivariable framework provides incremental prognostic information beyond conventional postoperative respiratory assessment and may improve early postoperative risk stratification. External validation is required before clinical implementation.
SN - 2077-0383
ER -