Abstract

Continuous, treatment-responsive measurement of motor state is an unmet need in Parkinson’s disease and a broad challenge for digital biomarkers: clinical gait scales are coarse and ordinal, and most digital measures are never validated beyond their derivation setting. We present a digital biomarker derived from full-mesh 3D human-pose reconstruction in standard monocular video, built from high-contrast within-patient treatment transitions and applied to out-of-sample patients. In a retrospective cohort (53 patients) it discriminated treatment states (cross-validated AUROC 0.88) and defined a continuous motor-state axis. Across six independent cohorts (266 subjects, 3,591 walks, eight sites, three continents) it showed consistent medication effects in the two medication-labelled cohorts and tracked clinical gait impairment in the four cohorts carrying clinical gait ratings; in a prospective cohort (21 patients) it preserved ordered transitions for medication and deep brain stimulation. On identical paired observations it was more responsive than the ordinal MDS-UPDRS Part III item 3.10 (standardized response mean 1.29 versus 0.83 internally, 0.92 versus 0.54 externally); its finer resolution also registered directional within-patient improvement more often, an advantage of measurement resolution that reaches parity once change is required to exceed the minimal detectable change, supporting a scalable, generalizable measurement tool.

This graphic explains a computer-vision method for tracking acute treatment response in Parkinson’s disease using standard monocular video without specialized hardware. It shows three steps: first, a single camera records the same patient before and after therapy; second, a markerless full-mesh 3D pose is reconstructed frame-by-frame; third, a gait-state biomarker is derived, with Levodopa and deep brain stimulation moving patients up the biomarker axis from negative to positive values. Validation data indicate the method was tested across 3,591 walks from 266 subjects at 8 sites on 3 continents. The biomarker correlates negatively with clinical gait impairment scores, showing that higher clinical impairment corresponds to lower biomarker scores. The biomarker detects changes more often than clinical scores, with 100 percent internal and 84 percent external detection rates of within-patient improvement compared to 68 and 37 percent for clinical gait scores, respectively.

Related

  1. Prospective Validation of Computer-Assisted Detection of Pulmonary Nodules and Lung Cancer in Chest X-Rays
    Marta Andreu, Carles Grimau, Mariona Quintana +14
    CancersPeer-reviewedCC BY 4.0Full textOncologyCrossrefEurope PMC
  2. A Two-Stage Questionnaire for Identifying Possible Parkinson's Disease: Machine-Learning Feature Selection and Interim Prospective Validation in Almaty, Kazakhstan.
    Ayaulym Nagashybay, Assanali Tokenov, Medet Mukushev +7
    Neurology internationalPeer-reviewedCC BYFull textNeurologyEurope PMC
  3. Computer vision, Parkinson’s disease, and the unfinished work of clinical translation
    Jane Alty, Maximilian U. Friedrich
    npj Parkinson's DiseasePeer-reviewedCC BYFull textNeurologyDOAJ
  4. AI in predicting the macrotrabecular-massive subtype of HCC and informing treatment selection: a multi-center and prospective validation study
    Ran Wei, Hanyu Jiang, Mengxuan Zuo +15
    NPJ Precision OncologyPeer-reviewedCC BY-NC-ND 4.0Full textGeneral medicinePMC
  5. A novel eye-tracking oculomotor score correlates with excessive daytime sleepiness and motor progression in Parkinson’s disease
    Renata Ramina Pessoa, Matheus Augusto Bernardi, William Ramires Sanches +8
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textNeurologyCrossref
BibTeX
@article{lange2026computer,
  title = {{Computer vision-derived gait-state tracking of acute treatment response in Parkinson’s disease: external and prospective validation}},
  author = {Florian Lange and Gamze Adaçay and Philipp Köberle and Sai Snigdha Kodali and Ghadir Abbas and Benedikt Weigl and Chi Wang Ip and Muhammad Haseeb and Yann Cordes and Tobias Binder and Muthuraman Muthuraman and Jens Volkmann and Robert Peach and Martin M. Reich},
  journal = {NPJ Parkinson's Disease},
  year = {2026},
  month = nov,
  doi = {10.1038/s41531-026-01614-2},
  url = {https://doi.org/10.1038/s41531-026-01614-2},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Computer vision-derived gait-state tracking of acute treatment response in Parkinson’s disease: external and prospective validation
AU  - Florian Lange
AU  - Gamze Adaçay
AU  - Philipp Köberle
AU  - Sai Snigdha Kodali
AU  - Ghadir Abbas
AU  - Benedikt Weigl
AU  - Chi Wang Ip
AU  - Muhammad Haseeb
AU  - Yann Cordes
AU  - Tobias Binder
AU  - Muthuraman Muthuraman
AU  - Jens Volkmann
AU  - Robert Peach
AU  - Martin M. Reich
PY  - 2026
DA  - 2026/11/11
JO  - NPJ Parkinson's Disease
DO  - 10.1038/s41531-026-01614-2
UR  - https://doi.org/10.1038/s41531-026-01614-2
AB  - Continuous, treatment-responsive measurement of motor state is an unmet need in Parkinson’s disease and a broad challenge for digital biomarkers: clinical gait scales are coarse and ordinal, and most digital measures are never validated beyond their derivation setting. We present a digital biomarker derived from full-mesh 3D human-pose reconstruction in standard monocular video, built from high-contrast within-patient treatment transitions and applied to out-of-sample patients. In a retrospective cohort (53 patients) it discriminated treatment states (cross-validated AUROC 0.88) and defined a continuous motor-state axis. Across six independent cohorts (266 subjects, 3,591 walks, eight sites, three continents) it showed consistent medication effects in the two medication-labelled cohorts and tracked clinical gait impairment in the four cohorts carrying clinical gait ratings; in a prospective cohort (21 patients) it preserved ordered transitions for medication and deep brain stimulation. On identical paired observations it was more responsive than the ordinal MDS-UPDRS Part III item 3.10 (standardized response mean 1.29 versus 0.83 internally, 0.92 versus 0.54 externally); its finer resolution also registered directional within-patient improvement more often, an advantage of measurement resolution that reaches parity once change is required to exceed the minimal detectable change, supporting a scalable, generalizable measurement tool.  This graphic explains a computer-vision method for tracking acute treatment response in Parkinson’s disease using standard monocular video without specialized hardware. It shows three steps: first, a single camera records the same patient before and after therapy; second, a markerless full-mesh 3D pose is reconstructed frame-by-frame; third, a gait-state biomarker is derived, with Levodopa and deep brain stimulation moving patients up the biomarker axis from negative to positive values. Validation data indicate the method was tested across 3,591 walks from 266 subjects at 8 sites on 3 continents. The biomarker correlates negatively with clinical gait impairment scores, showing that higher clinical impairment corresponds to lower biomarker scores. The biomarker detects changes more often than clinical scores, with 100 percent internal and 84 percent external detection rates of within-patient improvement compared to 68 and 37 percent for clinical gait scores, respectively.