Liver Lesion Detection with Task-Specific Organ-Level Tube Current Modulation: A Retrospective Reader Study
Abstract
Rationale and Objectives: To evaluate whether task-specific organ-level TCM improves hepatic lesion detection and abdominal image quality compared with uniform dose reduction at equivalent effective dose. Materials and Methods: In this single-center, IRB-approved, retrospective study, 22 oncology patients with 68 liver lesions (38 malignant, 30 benign) underwent chest-abdomen-pelvis CT. Using projection-domain noise emulation, five series were generated per patient: original acquisition (Orig-100); uniform reduction to 40% (UD-40) and 60% (UD-60) of effective dose; and organ-level TCM at matched 40% (Opt-40) and 60% (Opt-60). Three abdominal radiologists independently detected and classified lesions as benign or malignant and rated image quality on a 5-point Likert scale. Per-lesion sensitivity and image-quality scores were compared using the McNemar and Wilcoxon signed-rank tests, respectively. Malignant lesion-size thresholds (x50, x90) were estimated by logistic regression. Results: At 60% dose, Opt-60 malignant sensitivity was comparable to Orig-100 (82% vs 80%) and higher than UD-60 (67%). At 40% dose, Opt-40 exceeded UD-40 (68% vs 52%). All lesion detection improved similarly (Opt vs UD: 64% vs 54% at 40%; 77% vs 65% at 60%), with Opt-60 comparable to full dose (77% vs 76%). All Opt-versus-UD detection differences were significant (p <= 0.003). Opt-60 lesion-size thresholds (x50 = 3.3 mm; x90 = 15.7 mm) matched Orig-100 (3.7 mm, 16.8 mm). Abdominal image quality was higher with Opt than UD at both doses. Conclusion: At equivalent effective dose, organ-level TCM improved liver lesion detection over uniform reduction, with Opt-60 comparable to full dose. These findings support organ-level optimization for dose reduction while preferentially preserving image quality for liver metastasis detection.
Related
- Significant modulation of acoustoelectric current associated with charge density wave transitions
- End-to-end prostate lesion segmentation and detection from undersampled diffusion-weighted MRI
- Self-Attention-Aided Multi-Layer CNN-LSTM for Non-Uniform 4-Level Differential Amplitude Modulation and Detection with atmospheric turbulence for OWANs
- Modulation detection interference and its relationship to speech perception in noise in typically hearing adults
- Highly specific detection of weakly adsorbing glucose via a molecular clamp-mediated SERS strategy
BibTeX
@misc{medrano2026liver,
title = {{Liver Lesion Detection with Task-Specific Organ-Level Tube Current Modulation: A Retrospective Reader Study}},
author = {Maria Jose Medrano and Sen Wang and Kaylee W. Fang and Jennie Cao and Liyan Sun and Luyao Shen and Andy Shon and Luke Yoon and Grant M. Stevens and Adam S. Wang and Justin R. Tse},
howpublished = {arXiv},
year = {2026},
month = nov,
doi = {10.48550/arxiv.2607.25440},
eprint = {2607.25440},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2607.25440},
}
RIS
TY - UNPB
TI - Liver Lesion Detection with Task-Specific Organ-Level Tube Current Modulation: A Retrospective Reader Study
AU - Maria Jose Medrano
AU - Sen Wang
AU - Kaylee W. Fang
AU - Jennie Cao
AU - Liyan Sun
AU - Luyao Shen
AU - Andy Shon
AU - Luke Yoon
AU - Grant M. Stevens
AU - Adam S. Wang
AU - Justin R. Tse
PY - 2026
DA - 2026/11/25
PB - arXiv
DO - 10.48550/arxiv.2607.25440
UR - https://arxiv.org/abs/2607.25440
AB - Rationale and Objectives: To evaluate whether task-specific organ-level TCM improves hepatic lesion detection and abdominal image quality compared with uniform dose reduction at equivalent effective dose. Materials and Methods: In this single-center, IRB-approved, retrospective study, 22 oncology patients with 68 liver lesions (38 malignant, 30 benign) underwent chest-abdomen-pelvis CT. Using projection-domain noise emulation, five series were generated per patient: original acquisition (Orig-100); uniform reduction to 40% (UD-40) and 60% (UD-60) of effective dose; and organ-level TCM at matched 40% (Opt-40) and 60% (Opt-60). Three abdominal radiologists independently detected and classified lesions as benign or malignant and rated image quality on a 5-point Likert scale. Per-lesion sensitivity and image-quality scores were compared using the McNemar and Wilcoxon signed-rank tests, respectively. Malignant lesion-size thresholds (x50, x90) were estimated by logistic regression. Results: At 60% dose, Opt-60 malignant sensitivity was comparable to Orig-100 (82% vs 80%) and higher than UD-60 (67%). At 40% dose, Opt-40 exceeded UD-40 (68% vs 52%). All lesion detection improved similarly (Opt vs UD: 64% vs 54% at 40%; 77% vs 65% at 60%), with Opt-60 comparable to full dose (77% vs 76%). All Opt-versus-UD detection differences were significant (p <= 0.003). Opt-60 lesion-size thresholds (x50 = 3.3 mm; x90 = 15.7 mm) matched Orig-100 (3.7 mm, 16.8 mm). Abdominal image quality was higher with Opt than UD at both doses. Conclusion: At equivalent effective dose, organ-level TCM improved liver lesion detection over uniform reduction, with Opt-60 comparable to full dose. These findings support organ-level optimization for dose reduction while preferentially preserving image quality for liver metastasis detection.
ER -